Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Amaron Powerstack cells

Amaron Powerstack cells are a type of valve-regulated lead-acid (VRLA) battery designed for industrial applications. Here\\\\'s an overview of the Amaron Powerstack cells and their specifications: Key Features: Modular design for easy installation and maintenance High-performance VRLA technology for reliable power supply Low maintenance and self-discharge rate Wide operating temperature range (-20°C to 50°C) Compliance with international standards (IEC, UL, and CE) Types of Amaron Powerstack Cells: Amaron Powerstack 2V 200 Ah Cell: Capacity: 200 Ah Voltage: 2V Dimensions: 103 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 300 Ah Cell: Capacity: 300 Ah Voltage: 2V Dimensions: 123 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 400 Ah Cell: Capacity: 400 Ah Voltage: 2V Dimensions: 143 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 500 Ah Cell: Capacity: 500 Ah Voltage: 2V Dimensions: 163 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 600 Ah Cell: Capacity: 600 Ah Voltage: 2V Dimensions: 183 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 800 Ah Cell: Capacity: 800 Ah Voltage: 2V Dimensions: 203 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1000 Ah Cell: Capacity: 1000 Ah Voltage: 2V Dimensions: 223 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1200 Ah Cell: Capacity: 1200 Ah Voltage: 2V Dimensions: 243 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1500 Ah Cell: Capacity: 1500 Ah Voltage: 2V Dimensions: 263 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1800 Ah Cell: Capacity: 1800 Ah Voltage: 2V Dimensions: 283 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years **Amaron Powerstack 2V 200

Send Message
product image
Vertiv PowerBank 600 kVA Online UPS

Vertiv PowerBank 600 kVA Online UPS The Vertiv PowerBank 600 kVA Online UPS is designed for critical power applications, particularly in data centers and industrial environments. Here’s a comprehensive overview of its specifications, features, benefits, and considerations: Overview The Vertiv PowerBank 600 kVA UPS provides robust, uninterrupted power supply with advanced features for high availability, power quality, and energy efficiency. Key Specifications Power Rating: 600 kVA Input Voltage: Typically 400/415V (three-phase) Output Voltage: 400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion Efficiency: Up to 95% in normal operation and can reach 98% in eco mode Total Harmonic Distortion (THD): Typically <5% at full load Battery and Runtime Battery Type: Usually utilizes VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Configuration: Configurable based on requirements, with options for extended runtime Charging Time: Typically 4-8 hours for a full charge, depending on the battery type Runtime: Customizable based on load; options available for longer runtimes (requires additional battery packs) Features Advanced Monitoring: LCD display for real-time monitoring of status, input/output voltage, load percentage, battery status, and alarms. Redundancy: N+1 configuration for enhanced reliability and availability. Scalability: Capable of parallel operation with multiple units for increased capacity and redundancy. Smart Communication: SNMP, USB, and RS232 interfaces for remote management and monitoring. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Hot-Swap Batteries: Some configurations allow for battery replacement without turning off the UPS. Physical Characteristics Dimensions: Varies by model; typically around 120-150 cm in width and depth. Weight: Approximately 600-800 kg, depending on the configuration and battery type. Cooling: Generally air-cooled; ensure proper ventilation in the installation area. Benefits Power Quality: Provides clean, stable, and regulated power to sensitive equipment. High Availability: Designed for critical loads requiring uninterrupted power supply. Energy Efficiency: High-efficiency modes help reduce operational costs. User-Friendly: Intuitive interface and comprehensive management software facilitate easy operation. Considerations Installation: Professional installation is recommended to optimize configuration and ensure compliance with electrical standards. Maintenance: Regular inspections and battery maintenance are crucial for ensuring reliability and longevity. Environmental Conditions: Requires proper ventilation and should be installed in a climate-controlled environment to avoid overheating. Cost: Initial investment can be substantial; consider the total cost of ownership, including maintenance and energy savings. Applications Data Centers Telecommunications Infrastructure Industrial Power Applications Medical Facilities Financial Institutions Conclusion The Vertiv PowerBank 600 kVA UPS is a powerful and reliable solution for ensuring continuous power supply and protecting critical infrastructure.

Send Message
product image
Vertiv Hiplus 80-800 KVA Online Ups

UPS Renting Services HIPULSE UPS (80-800 KVA) It is a range of uninterruptible power supply (UPS) systems manufactured by a company called HIPULSE. These UPS systems are designed to provide reliable and continuous power protection for a wide range of applications, from small to large-scale industrial and commercial environments. The HIPULSE UPS range typically covers a power capacity range of 80-800 kilovolt-amperes (kVA). Most of Benefits from Universal Power System: Features: On-Line Double C???onversion IGBT-based PWM Inverter Wide input voltage tolerance (+15 / -15%) Wide input frequency tolerance (45Hz-65Hz) Capability to handle: - High crest factor loads - 100% non-linear loads - 100% unbalanced loads Built-in maintenance bypass (Single and 1+N Models) Common battery sharing kit (optional) with 1+1 configuration Built-in maintenance bypass (Single and 1+N Models) Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA UPS Renting Services UPS Renting Services S7400 UPS (10-400 KVA) THE S7400 UPS IS A SERIES OF UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEMS MANUFACTURED BY AN UNDISCLOSED COMPANY. THESE UPS SYSTEMS ARE DESIGNED TO PROVIDE RELIABLE AND CONTINUOUS POWER PROTECTION FOR A WIDE RANGE OF APPLICATIONS. THE S7400 SERIES TYPICALLY COVERS A POWER CAPACITY RANGE OF 10 KVA TO 400 KVA. Features: High performance IGBT PWM(Pulse Wave Modification) technology for pure sinewave output LBS configuration for super critical loads True parallelability up to six modules Netcom kit for remote monitoring BMS Connectivity through modbus Remote alarm monitor (RAM) Hardware for Fault Diagnostic Unit (FDU), data logger and power monitoring software Communication card for dial-up monitoring UPS Series 7400 The Series 7400 UPS offers True On-line Field Proven UPS system to maximize Uptime of your Critical Application. The Series 7400 offers a wide range from 10 kVA to 750 kVA single phase systems. The Series 7400 UPS System has a proven track - record of unmatched reliability to support your sensitive and costly equipment, offering maximum availability to virtually any application. The Series 7400 is carefully designed to address the “load power factor” (0.7 lagging upwards) and “non linearity” that critical applications demand. In-built output isolation transformer To offer galvanic isolation between your critical application and the Mains, while feeding the load through the Inverter. Battery Circuit Breaker (BCB): To ensure “Safety” and to protect your “Battery Life”, unlike using DC Isolator. Usage of BCB is much safer in terms of personal hazards on a running system than a DC Isolator. Under Voltage Trip coil of BCB prevents deep-discharging of battery, which cannot be achieved by a DC Isolator. RS-232 Serial port : For carrying out on-line monitoring of Alarm and Status. Optional attachments such as IBM-AS 400 Interface Card/ Relay Interface Card help you to integrate the UPS with your network effectively. High efficiency performance High reliability to maximise system availability Handles 3:1 crest factor loads without de-rating

Send Message
product image
UPS ( Uninterrupted Power Supplies)

UPS ( Uninterrupted Power Supplies) An uninterruptible power supply or uninterruptible power source (UPS) is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery run-time of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment. It is a type of continual power system. Features of UPS Systems: Line Interactive Range in 600VA and 2000VA with minimal battery backup. We have an online range of UPSs in 1,2 and 3 kVA category both with an internal battery backup of 10 minutes and with a longer battery backup of up to 4 hours. We offer a mini range of UPSs of capacities 6,10 and 20 kVA with options of internal isolation transformers both in single-phase and three-phase options. We have an ITA series of Hitech UPS systems in the range of 6 to 40 kVA. Hiplulse U series of UPS range with internal isolation transformers essentially meant for industrial applications.

Send Message
product image
Exide Bike Battery In Bhiwadi

Exide bike batteries are designed for high performance and durability in two-wheelers. Here are key details: Type: VRLA (Valve Regulated Lead Acid) and conventional flooded batteries, suitable for different bike models. Features: Maintenance-free, spill-proof, vibration-resistant, and designed for quick starting power. Applications: Used in motorcycles, scooters, and other two-wheelers for reliable starting and backup power. Durability: High resistance to extreme temperatures and rough road conditions. Maintenance: Low maintenance with easy water level checks (for conventional types). Exide is a trusted brand for two-wheeler batteries, known for its long-lasting performance and reliability.

Send Message

Still searching for
balanced power?