Items tagged with 'enterprise power'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Vertiv Data Center Ups

Vertiv is a well-known provider of critical digital infrastructure and continuity solutions, including uninterruptible power supplies (UPS) for data centers. They offer a variety of UPS systems designed to meet the needs of different types of data centers, from small edge installations to large enterprise facilities. Here are some of the main types of UPS systems offered by Vertiv: 1. Single-Phase UPS Vertiv Liebert GXT5: A compact UPS designed for small to medium data centers, offering high efficiency and power density. Vertiv Liebert PSI5: A line-interactive UPS that provides reliable power protection for small IT environments. 2. Three-Phase UPS Vertiv Liebert EXS: A modular UPS solution that offers scalability and flexibility for medium to large data centers. Vertiv Liebert APM: A highly efficient UPS designed for large enterprise environments, providing advanced features and high availability. Vertiv Liebert NXC: A robust UPS solution designed for mission-critical applications, offering high efficiency and reliability. 3. Modular UPS Vertiv Liebert DPA: A modular UPS system that allows for incremental capacity upgrades, making it ideal for growing data centers. 4. Flywheel UPS Vertiv Liebert FPC: A flywheel energy storage system that provides short-term backup power and is often used in conjunction with traditional UPS systems for enhanced reliability. 5. Lithium-Ion UPS Vertiv Liebert APS: A UPS system that utilizes lithium-ion battery technology for longer life and reduced maintenance compared to traditional lead-acid batteries. 6. Eco-Friendly Solutions Vertiv also focuses on energy-efficient and environmentally friendly solutions, such as systems that comply with various sustainability standards and regulations. Key Features Scalability: Many Vertiv UPS systems are designed to be modular, allowing for easy expansion as data center needs grow. Efficiency: High-efficiency designs help reduce energy costs and improve overall sustainability. Advanced Monitoring: Vertiv offers solutions with integrated monitoring capabilities, allowing for real-time performance tracking and proactive maintenance alerts. Redundancy Options: Many systems support N+1 or 2N configurations for enhanced reliability. Applications Enterprise Data Centers: Large facilities requiring high availability and redundancy. Edge Computing: Solutions designed for smaller, distributed data centers. Telecommunications: Power protection for critical telecom infrastructure. Healthcare: Ensuring uptime for critical medical equipment and data. When choosing a UPS system, it's essential to consider factors such as load requirements, runtime needs, efficiency, and the specific environment in which the UPS will operate. For the most accurate and tailored solutions, it's advisable to consult with a Vertiv representative or a certified distributor.

Send Message
product image
Amaron Powerstack cells

Amaron Powerstack cells are a type of valve-regulated lead-acid (VRLA) battery designed for industrial applications. Here\\\\'s an overview of the Amaron Powerstack cells and their specifications: Key Features: Modular design for easy installation and maintenance High-performance VRLA technology for reliable power supply Low maintenance and self-discharge rate Wide operating temperature range (-20°C to 50°C) Compliance with international standards (IEC, UL, and CE) Types of Amaron Powerstack Cells: Amaron Powerstack 2V 200 Ah Cell: Capacity: 200 Ah Voltage: 2V Dimensions: 103 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 300 Ah Cell: Capacity: 300 Ah Voltage: 2V Dimensions: 123 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 400 Ah Cell: Capacity: 400 Ah Voltage: 2V Dimensions: 143 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 500 Ah Cell: Capacity: 500 Ah Voltage: 2V Dimensions: 163 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 600 Ah Cell: Capacity: 600 Ah Voltage: 2V Dimensions: 183 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 800 Ah Cell: Capacity: 800 Ah Voltage: 2V Dimensions: 203 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1000 Ah Cell: Capacity: 1000 Ah Voltage: 2V Dimensions: 223 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1200 Ah Cell: Capacity: 1200 Ah Voltage: 2V Dimensions: 243 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1500 Ah Cell: Capacity: 1500 Ah Voltage: 2V Dimensions: 263 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1800 Ah Cell: Capacity: 1800 Ah Voltage: 2V Dimensions: 283 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years **Amaron Powerstack 2V 200

Send Message
product image
Amaron Batteries Apc Ups In Sector 53 Noida

Using Amaron batteries with APC (American Power Conversion) UPS (Uninterruptible Power Supply) systems can provide reliable backup power. Here’s a comprehensive overview of how to pair them effectively: APC UPS Overview Purpose: Provides emergency power during outages and stabilizes voltage fluctuations. Types: Ranges from consumer models to enterprise-level systems. Key Features: Automatic Voltage Regulation (AVR): Stabilizes voltage. Surge Protection: Protects connected devices from surges. LCD Display: Displays battery status, load level, and other metrics. Amaron Batteries Overview Type: Typically lead-acid (both conventional and maintenance-free) or possibly lithium-ion for some applications. Voltage Options: Commonly available in 12V configurations, suitable for UPS systems. Capacity: Various capacities (e.g., 46Ah, 100Ah, 150Ah), depending on the UPS model and required backup time. Compatibility Sizing: Ensure the Amaron battery’s voltage matches the UPS system (e.g., a 12V battery for a 12V UPS). Capacity Matching: Choose a battery capacity that meets or exceeds the UPS\\\\'s requirements for runtime during power outages. Calculate based on the load you wish to support. Installation Connection: Connect the Amaron battery to the UPS according to the manufacturer\\\\'s instructions. Typically, you\\\\'ll connect the positive (+) terminal to the UPS\\\\'s positive input and the negative (-) terminal to the negative input. Securing: Ensure that all connections are tight and secure to prevent arcing or disconnections. Performance and Benefits Extended Runtime: Using higher-capacity Amaron batteries can extend the runtime of the UPS during power outages. Reliability: Amaron batteries are known for their durability and ability to handle deep discharges, making them suitable for UPS applications. Maintenance-Free Options: Many Amaron batteries are designed to be maintenance-free, reducing the need for regular upkeep. Maintenance Regular Checks: Periodically inspect the UPS and battery connections for corrosion and tightness. Battery Health: Monitor the battery’s voltage and overall health using a multimeter or UPS diagnostics. Replacement: Replace the battery as needed based on performance degradation or if the battery shows signs of failure. Safety Precautions Ventilation: Ensure proper ventilation during operation to prevent gas buildup, especially with lead-acid batteries. Overcharging: Monitor charging cycles to prevent overcharging, which can lead to battery damage. Conclusion Combining Amaron batteries with APC UPS systems can enhance your power reliability and provide an effective backup solution. Always refer to the specific user manuals for both the UPS and batteries to ensure compatibility and proper installation procedures.

Send Message
product image
Vertiv 3 kVA UPS In Rohini Delhi

The Vertiv 3 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection and backup for critical equipment, making it ideal for IT environments, data centers, and small to medium enterprises. Here are the key details: Specifications: Power Rating: 3 kVA (approximately 2400 watts, depending on the power factor) Input Voltage: Generally operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronic devices. Battery Type: Typically uses sealed lead-acid or lithium-ion batteries (model-dependent). Features: Automatic Voltage Regulation (AVR): Stabilizes output voltage, protecting against surges and sags. LCD Display: Provides real-time monitoring of battery status, load levels, and input/output voltage. Multiple Outlets: Usually equipped with multiple output sockets for connecting various devices. Communication Ports: USB, RS-232, or network management ports for monitoring and management via software. Hot-Swappable Batteries: Allows for battery replacement without the need to power down the UPS. Applications: IT Equipment: Ideal for servers, switches, and networking equipment. Small to Medium Enterprises: Suitable for office equipment, point-of-sale systems, and workstations. Telecommunications: Used to provide backup power for telecom equipment. Advantages: Reliable Power Backup: Ensures continuous operation during power interruptions, minimizing data loss and downtime. Compact Design: Space-efficient design for easy installation in various environments. Energy Efficiency: Many models feature energy-saving modes and high efficiency. Considerations: Battery Runtime: Assess the expected runtime based on the total load connected; higher loads will decrease runtime. Maintenance: Regular maintenance and timely battery replacements are crucial for optimal performance. Always refer to the specific model’s user manual for detailed specifications, features, and installation instructions to ensure proper use and maintenance.

Send Message
product image
Vertiv 2 kVA UPS In Patel Nagar Gurgaon

The Vertiv 2 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protection for various electronic devices, making it suitable for both IT and industrial applications. Here are the key details: Specifications: Power Rating: 2 kVA (approximately 1600 watts, depending on the power factor) Input Voltage: Typically operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave for compatibility with sensitive equipment. Battery Type: Generally sealed lead-acid or lithium-ion (varies by model). Features: Automatic Voltage Regulation (AVR): Protects against voltage fluctuations by stabilizing the output. LCD Display: Provides real-time data on battery status, load level, and input/output voltage. Multiple Outlets: Usually includes several output sockets for connecting multiple devices. Communication Ports: USB, RS-232, or network management options for monitoring and management. Hot-Swappable Batteries: Enables battery replacement without shutting down the UPS. Applications: IT Infrastructure: Ideal for servers, networking equipment, and critical computing systems. Small to Medium Enterprises: Suitable for point-of-sale systems, office equipment, and telecommunications. Industrial Use: Can be used for powering essential equipment in various industrial settings. Advantages: Reliable Backup Power: Ensures continuity during power outages, preventing data loss and downtime. Compact and Efficient: Designed for easy installation and energy efficiency. Scalability: Can be used in conjunction with other UPS systems for larger setups. Considerations: Battery Runtime: Evaluate the expected runtime based on the connected load; larger loads will reduce runtime. Maintenance: Regular maintenance checks and timely battery replacements are essential for performance. Always consult the specific model’s user manual for detailed specifications, features, and installation instructions tailored to your needs.

Send Message