Noida
+918076792323

'full featured transformer'

Items tagged with 'full featured transformer'

product image
Emerson Vertiv 6KVA Ups In Mehrauli Gurugram

The Emerson Vertiv 6KVA 1:1 Phase Online UPS with an inbuilt isolation transformer is designed to provide reliable power protection for critical applications, particularly in environments requiring high levels of power quality and isolation. Here are the key specifications and features: Specifications: Power Rating: 6kVA / 4.8kW Input Voltage: 230V AC Output Voltage: 230V AC Input Frequency: 50/60 Hz Output Frequency: 50/60 Hz Efficiency: Up to 92% (depending on load) Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Typically provides backup for 10-15 minutes at full load (depending on battery configuration) Dimensions: Varies by model, typically around 600 x 400 x 800 mm Weight: Approximately 50-70 kg (depending on configuration) Features: True Online Operation: Provides continuous power supply without any transfer time, ensuring zero downtime. Inbuilt Isolation Transformer: Enhances power quality by isolating the load from input disturbances and providing additional safety. High Efficiency: Reduces energy costs and heat generation, contributing to a more sustainable operation. Advanced Battery Management: Prolongs battery life and ensures optimal performance through intelligent charging and discharging. LCD Display: Provides real-time monitoring of UPS status, including input/output voltage, load percentage, and battery status. Modular Design: Allows for easy maintenance and upgrades. Multiple Communication Ports: Includes RS-232, USB, and optional SNMP for remote monitoring and management. Applications: Data Centers: Ensures reliable power for critical IT infrastructure. Telecommunications: Protects sensitive telecom equipment from power disturbances. Medical Facilities: Supports essential medical equipment requiring uninterrupted power. Industrial Applications: Suitable for manufacturing and process control systems. Services: Engineering: Customized solutions for specific power requirements. Installation: Professional installation services to ensure proper setup. Preventive Maintenance: Regular maintenance to ensure optimal performance and reliability. Monitoring: Remote monitoring services to track UPS performance and health. Recycling: Environmentally responsible disposal of old batteries and equipment. Certifications: ISO 9001: Quality management system certification. ISO 14001: Environmental management system certification. ISO 45001: Occupational health and safety management system certification. CE: Conforms to European Union safety and environmental standards. UL: Conforms to Underwriters Laboratories safety standards. Warranty: Standard Warranty: Typically offers a 2-year warranty on the UPS system and batteries. Extended Warranty: Options for additional warranty coverage may be available. Additional Information: The Emerson Vertiv 6KVA Online UPS with an inbuilt isolation transformer is designed to meet the demanding power quality requirements of various industries. Its features ensure that critical systems remain operational even during power interruptions, making it a reliable choice for businesses that cannot afford downtime.

Send Message
product image
Vertiv Hiplus 80-800 KVA Online Ups

UPS Renting Services HIPULSE UPS (80-800 KVA) It is a range of uninterruptible power supply (UPS) systems manufactured by a company called HIPULSE. These UPS systems are designed to provide reliable and continuous power protection for a wide range of applications, from small to large-scale industrial and commercial environments. The HIPULSE UPS range typically covers a power capacity range of 80-800 kilovolt-amperes (kVA). Most of Benefits from Universal Power System: Features: On-Line Double C???onversion IGBT-based PWM Inverter Wide input voltage tolerance (+15 / -15%) Wide input frequency tolerance (45Hz-65Hz) Capability to handle: - High crest factor loads - 100% non-linear loads - 100% unbalanced loads Built-in maintenance bypass (Single and 1+N Models) Common battery sharing kit (optional) with 1+1 configuration Built-in maintenance bypass (Single and 1+N Models) Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA UPS Renting Services UPS Renting Services S7400 UPS (10-400 KVA) THE S7400 UPS IS A SERIES OF UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEMS MANUFACTURED BY AN UNDISCLOSED COMPANY. THESE UPS SYSTEMS ARE DESIGNED TO PROVIDE RELIABLE AND CONTINUOUS POWER PROTECTION FOR A WIDE RANGE OF APPLICATIONS. THE S7400 SERIES TYPICALLY COVERS A POWER CAPACITY RANGE OF 10 KVA TO 400 KVA. Features: High performance IGBT PWM(Pulse Wave Modification) technology for pure sinewave output LBS configuration for super critical loads True parallelability up to six modules Netcom kit for remote monitoring BMS Connectivity through modbus Remote alarm monitor (RAM) Hardware for Fault Diagnostic Unit (FDU), data logger and power monitoring software Communication card for dial-up monitoring UPS Series 7400 The Series 7400 UPS offers True On-line Field Proven UPS system to maximize Uptime of your Critical Application. The Series 7400 offers a wide range from 10 kVA to 750 kVA single phase systems. The Series 7400 UPS System has a proven track - record of unmatched reliability to support your sensitive and costly equipment, offering maximum availability to virtually any application. The Series 7400 is carefully designed to address the “load power factor” (0.7 lagging upwards) and “non linearity” that critical applications demand. In-built output isolation transformer To offer galvanic isolation between your critical application and the Mains, while feeding the load through the Inverter. Battery Circuit Breaker (BCB): To ensure “Safety” and to protect your “Battery Life”, unlike using DC Isolator. Usage of BCB is much safer in terms of personal hazards on a running system than a DC Isolator. Under Voltage Trip coil of BCB prevents deep-discharging of battery, which cannot be achieved by a DC Isolator. RS-232 Serial port : For carrying out on-line monitoring of Alarm and Status. Optional attachments such as IBM-AS 400 Interface Card/ Relay Interface Card help you to integrate the UPS with your network effectively. High efficiency performance High reliability to maximise system availability Handles 3:1 crest factor loads without de-rating

Send Message
product image
Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
ALL TYPES OF UPS REPAIR

UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks: Battery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs. Power Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power. Overheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement. Inverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging. Internal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
Amaron GO BATTERY IN DELHI

Amaron GO Car Battery is one of the popular car batteries offered by Amaron, known for its reliable performance, durability, and long lifespan. Here’s a detailed overview of the Amaron GO car battery: Key Features of Amaron GO Car Battery: Technology: Advanced Lead-Acid Technology: The Amaron GO uses lead-acid technology, which is widely used for automotive batteries due to its affordability and effectiveness. HVR (High Vibration Resistance): Designed to withstand high vibrations typically found in modern vehicles, ensuring a longer life even in challenging conditions. Capacity and Voltage: The Amaron GO series offers a wide range of car battery capacities to fit different types of vehicles, typically ranging from 35Ah to 70Ah or higher, with a nominal voltage of 12V. Enhanced Performance: Long Life: Amaron GO batteries are designed for long-lasting performance, offering up to 48 months of warranty (depending on model and usage). Low Maintenance: The Amaron GO is a maintenance-free battery, meaning you don’t need to top it up with water, unlike traditional flooded lead-acid batteries. Leakproof: The battery is designed to prevent leakage, which is a common issue with old or poorly maintained batteries. Durability: Heat Resistance: The Amaron GO car batteries are built to handle extreme weather conditions, making them suitable for both hot and cold climates. Vibration Resistance: With its vibration-resistant design, the battery can last longer even in vehicles that experience high levels of vibration, such as SUVs and trucks. Quick Start Power: The Amaron GO battery is designed to provide strong cranking power for reliable engine starts, even in cold weather conditions. Its quick recharge capability allows your vehicle to return to full charge efficiently. Warranty: Warranty: Typically, the Amaron GO series comes with a 48-month warranty, including a 24-month free replacement and 24-month pro-rata. This warranty may vary depending on your region and the specific model. Applications: Personal Cars: Suitable for most types of personal vehicles like sedans, hatchbacks, and SUVs. Commercial Vehicles: Can also be used for light commercial vehicles, depending on the specific capacity and requirements. Specifications (for a typical Amaron GO battery): Voltage: 12V Capacity: 35Ah, 40Ah, 50Ah, 60Ah, 70Ah (depending on the vehicle model) Cold Cranking Amps (CCA): This varies by battery model, typically ranging from 400 to 650 CCA for vehicles that require more starting power. Warranty: 48 months (subject to terms and conditions). Dimensions: Varies by capacity, but typically around 240mm (L) x 175mm (W) x 190mm (H). Weight: Between 9kg and 20kg, depending on the capacity. Advantages: Maintenance-Free: No need to add water or perform regular maintenance. Reliability: Known for excellent reliability, ensuring consistent performance throughout the year. Long Life and Durability: High durability even in extreme conditions, with a long lifespan and reduced chances of failure. Environmentally Friendly: Made using recyclable materials and follows the necessary environmental standards. Disadvantages: Initial Cost: Amaron batteries might have a higher upfront cost compared to some budget-friendly alternatives, but their longevity and performance can make them a good value over time. Conclusion: The Amaron GO Car Battery is a great choice for vehicle owners looking for a reliable, long-lasting, and maintenance-free battery. Whether you have a compact car, an SUV, or a commercial vehicle, the Amaron GO offers excellent starting power, durability, and performance. With a strong warranty and minimal maintenance requirements, it is a solid option for anyone in need of a quality automotive battery.

Send Message
product image
Amaron Quanta 12V 130Ah Battery In Bhiwadi

The Amaron Quanta 12V 130Ah batteries are lead-acid batteries typically used for solar power storage, backup power systems, and other applications that require reliable energy storage. Here's a detailed overview of this battery: Key Features of Amaron Quanta 12V 130Ah Battery: Battery Type: Lead-Acid: This is a type of flooded or sealed (VRLA) lead-acid battery, suitable for deep cycle applications. 12V System: Designed for systems that operate on a 12V DC supply, often used in small-scale solar energy systems, inverters, and backup power setups. Capacity: 130Ah (Ampere-hour): This indicates the battery’s storage capacity. It means the battery can deliver 130 amps for 1 hour or 1 amp for 130 hours at a nominal voltage of 12V. For example, if the system uses 1A of current, the battery will last for around 130 hours before needing a recharge. Applications: Solar Power Systems: To store energy generated by solar panels. UPS (Uninterruptible Power Supply): Provides backup during power outages. Off-Grid Systems: Stores energy for homes or businesses in remote areas. Electric Vehicles and RVs: Sometimes used for backup and auxiliary power. Charging and Discharging: Charging: The battery can be charged through solar panels, inverters, or a regular charger. It is recommended to avoid deep discharges to extend the battery life. Discharging: It should not be discharged fully for longevity. Typically, a depth of discharge (DoD) of 50% to 70% is ideal for long-term use. Battery Life: Cycle Life: Typically, a lead-acid battery like the Amaron Quanta 12V 130Ah can last around 3-5 years, depending on usage and maintenance. Proper charging and maintenance (like keeping the terminals clean and ensuring adequate ventilation) can improve the lifespan of the battery. Advantages: Reliable and Cost-Effective: Lead-acid batteries are typically less expensive than other types of batteries, like lithium-ion. Widely Available: Amaron is a well-known brand, and their batteries are widely available and easy to replace. Maintenance: Flooded Lead-Acid: If it’s a flooded type, you may need to periodically check the water levels and top up with distilled water. VRLA (Valve-Regulated Lead-Acid): If it's a sealed type, it requires less maintenance as it’s sealed and does not need water refills. Specifications: Voltage: 12V Capacity: 130Ah Weight: Around 40-45 kg (approx.), depending on the specific model and construction type. Dimensions: Varies by model, but typically it is about 410mm (L) x 175mm (W) x 240mm (H). Conclusion: The Amaron Quanta 12V 130Ah battery is a good choice for off-grid solar systems, backup power applications, or any system requiring long-lasting energy storage. It offers a solid balance of performance, cost-effectiveness, and reliability. Proper care and maintenance will ensure it provides reliable service for years to come.

Send Message
product image
Vertiv 60 kVA to 200 kVA Ups

The Liebert SX series from Vertiv offers UPS systems ranging from 60 kVA to 200 kVA, utilizing full IGBT double conversion technology. This design enhances efficiency, reduces installation and operational costs, and provides reliable power backup solutions for critical applications. Key Features of Liebert SX 60kVA to 200kVA Modular Design: The Liebert SX series features a modular architecture that allows for easy scalability and maintenance. Front Access Design: This design minimizes repair time and optimizes installation and serviceability, making it user-friendly. Environmental Standards: The Liebert SX series is designed to meet high environmental standards, promoting energy efficiency and sustainability. ID Card for Each UPS: Each unit comes with an ID card that includes all working parameters, which helps in reducing downtime during maintenance. Applications Power Backup: Ideal for critical applications requiring uninterrupted power supply. Data Centers: Suitable for use in data centers where reliability and efficiency are paramount. Industrial Use: Can be utilized in various industrial settings to ensure consistent power availability. Contact Information for Further Inquiries Company: Universal Power System Location: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001 Mobile - 8744823336 Email: info@universalpower.co.in

Send Message

Still searching for