Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Amaron Tubular Battery In Faridabad

Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points: Design: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions. Applications: Commonly used in inverters, solar power systems, and other backup power solutions. Durability: Known for high resistance to corrosion and low maintenance requirements. Performance: Excellent charge retention and high power output, even in harsh conditions. Maintenance: Requires periodic checking of water levels and occasional equalization charging. Amaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.

Send Message
product image
Vertiv 60 kVA UPS

The Vertiv 60 kVA Online UPS is an uninterruptible power supply (UPS) designed to provide reliable and continuous power to critical equipment in case of power interruptions. Here are some key details and features typically associated with this kind of UPS: Key Features: Online UPS Technology: The Vertiv 60 kVA UPS uses online double-conversion technology, meaning it provides constant, clean, and stable power to connected equipment by continuously converting incoming AC power to DC and then back to AC. High Capacity: With a capacity of 60 kVA (kilo volt-amperes), this UPS is ideal for medium to large-sized businesses or industrial applications that require a significant amount of power protection, such as data centers, manufacturing equipment, or IT infrastructure. Energy Efficiency: These systems are typically designed to offer high efficiency, reducing operational costs while maintaining reliable performance. Some models offer "eco-mode" functionality to optimize efficiency during non-critical times. Battery Management: Vertiv UPS units generally feature advanced battery management technology that ensures longer battery life, more efficient charging, and optimal performance. The batteries are usually hot-swappable, allowing for maintenance without shutting down the system. Compact Design: Despite its high capacity, the Vertiv 60 kVA Online UPS is designed to have a relatively compact form factor, making it easier to integrate into limited spaces in data centers or industrial settings. Communication and Monitoring: Many Vertiv UPS systems come equipped with intelligent monitoring systems that allow users to track performance, status, and any faults. This can often be done remotely through a web interface or software. Bypass Capability: Some models offer an internal bypass, which allows the load to continue operating even during maintenance or if the UPS needs to be shut down for any reason. Typical Applications: Data Centers: Ensuring that critical server equipment continues running during power interruptions. Industrial Automation: Protecting machinery and control systems from voltage sags or outages. Healthcare: Protecting medical equipment that is sensitive to power fluctuations. Telecommunications: Ensuring consistent power supply to communication infrastructure. Advantages: Continuous Power Protection: Ideal for environments where power outages can cause data loss, downtime, or even equipment damage. Scalability: Can be paired with additional units or battery banks for higher power requirements. Reliability: The Vertiv brand is well-regarded in the power protection industry for producing durable and dependable UPS systems.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
12V 9Ah Battery

The Amaron Quanta 12V 9Ah battery is a sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery designed for reliable performance in various applications. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months Features: Corrosion-Resistant Alloy: Enhances cyclic life, especially in tropical environments. Low Self-Discharge Rate: Ensures longer shelf life and reliability. Maintenance-Free: No regular maintenance required, providing convenience. Applications: UPS Systems: Ideal for backup power in computers and electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications requiring dependable power. This battery is known for its durability and efficiency, making it a preferred choice for users needing a reliable power source. The Amaron Quanta 12V 9Ah battery is a high-performance sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery, ideal for various applications requiring dependable power. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months offsite warranty Features: Reliable Functionality: Designed for consistent performance in critical applications. Fast Recharging: Capable of quick recharging to minimize downtime. Sealed Maintenance-Free: No need for regular maintenance, enhancing convenience. Heavy Duty Alloy Construction: Built to withstand deep discharge and overcharge conditions. Applications: UPS Systems: Ideal for providing backup power to computers and other electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications where reliable power is crucial. Warranty Information: Warranty Type: 12 Months Offsite Warranty Service: Warranty service available at the nearest service center. This battery is widely recognized for its high quality and reliability, making it a popular choice among users needing dependable power solutions.

Send Message
product image
12V 7Ah battery

The Amaron Quanta 12V 7Ah battery is a sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery designed for reliable power supply in UPS applications. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 7 Ampere Hours Dimensions: 151 mm x 65 mm x 100 mm Weight: Approximately 1.5 kg Warranty: 12 months This battery is suitable for various applications, including UPS systems and emergency lighting. Features: Reliable Functionality: Designed for consistent performance in critical applications. Fast Recharging: Capable of quick recharging to minimize downtime. Sealed Maintenance-Free: No need for regular maintenance, enhancing convenience. Heavy Duty Alloy Construction: Built to withstand deep discharge and overcharge conditions. Applications: UPS Systems: Ideal for providing backup power to computers and other electronic devices. Electric Vehicles: Can be used in electric scooters and other vehicles requiring compact power sources. Medical Equipment: Suitable for powering essential medical devices. Industrial Equipment: Effective in various industrial applications where reliable power is crucial. Warranty Information: Warranty Type: 1 Year Carry-in Warranty Service: Warranty service available at the nearest service center. This battery is widely recognized for its high quality and reliability, making it a popular choice among users needing dependable power solutions.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
Battery

The Amaron Quanta 12V 42Ah battery, also known as the 12AL042, is a sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery designed for reliable performance in various applications, particularly in UPS systems and other power backup solutions. Here are the Product Details: Product Overview Type: Lead Acid Battery Model: Amaron Quanta 12V/42Ah (12AL042) Vendor: Amaron Quanta Key Features Reliable Functionality: Designed for efficient backup and uninterrupted power supply. Sealed Maintenance-Free: No need for regular maintenance, ensuring hassle-free operation. Fast Charging Capability: Suitable for quick recharging. Eco-Friendly: Low carbon footprint due to advanced AGM technology. Product Specifications Battery Capacity: 42 Ah Battery Type: SMF-VRLA (Sealed Maintenance Free - Valve Regulated Lead Acid) Battery Voltage: 12 V Weight: 14 kg Dimensions: 19.9 x 16.7 x 17.5 cm Warranty & Support Warranty: 12 months (some vendors may offer up to 24 months). In Box Accessories: Warranty card included. Applications Suitable for use in: Online UPS systems Telecommunication equipment Fire alarm and security systems Office automation equipment Laboratory equipment Shipping & Delivery Shipping: Usually calculated at checkout. Delivery Time: Generally within 3-10 working days, depending on location. Same Day Delivery: Available in select areas. Additional Information The Amaron Quanta 12V 42Ah battery is engineered for high performance and reliability, making it suitable for various applications that require a stable power supply.

Send Message
product image
Battery

The Amaron Quanta 12V 18Ah battery, also known as the 12AL018, is a sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery designed for various applications. Here are the Product Overview Type: Lead Acid Battery Model: Amaron Quanta 12V/18Ah (12AL018) Vendor: Amaron Quanta Key Features Reliable Functionality: Designed for consistent performance. Fast Recharging: Suitable for quick charging needs. Sealed Maintenance Free: No need for regular maintenance. Heavy Duty Alloy Construction: Enhanced durability and longevity. Delivery Options: Free delivery for Bangalore-based buyers. Buy-back options available for Bangalore buyers. Free delivery for other locations on orders above 50 units. Warranty & Support Warranty: 1 Year Carry-in Warranty from the date of purchase. Shipping & Delivery Shipping: Products are shipped the next business day. Delivery Time: Typically within 3-10 working days. Same Day Delivery: Available for Bangalore buyers. Additional Information The Amaron Quanta 12V/18Ah battery is manufactured using quality assured materials and advanced techniques, ensuring it meets high standards in performance and reliability. For more details, you can visit the product page here.