Noida
+918076792323

'individual desktop pcs'

Items tagged with 'individual desktop pcs'

product image
UPS

The VERTIV Liebert ITON CX 1000VA UPS is a line-interactive uninterruptible power supply designed for home and small office use. Below are the details regarding its unboxing and quick testing. Unboxing Details Packaging: The UPS comes securely packaged to prevent damage during transit. Ensure to check for any visible signs of damage upon receipt. Included Items: VERTIV Liebert ITON CX 1000VA UPS unit User manual and installation guide Power cord with UK outlet Warranty card Initial Inspection: Check the UPS for any physical damage. Verify that all components are included as per the manual. Quick Test Procedure Setup: Place the UPS in a well-ventilated area. Connect the power cord to the UPS and plug it into a wall outlet. Power On: Press the power button to turn on the UPS. Observe the LED indicators: Green Light: Indicates AC mode (normal operation). Red Light: Indicates a fault condition. Battery Mode Test: To test the battery mode, disconnect the UPS from the wall outlet. Ensure that the UPS switches to battery mode automatically. Check the runtime by connecting a load (e.g., a computer) and monitor how long the UPS can sustain power. Load Testing: Connect a load that draws approximately 120W (e.g., a standard desktop computer). Monitor the backup time, which should be around 30 minutes under this load. Recharge Time: After the test, reconnect the UPS to the wall outlet. Note that the typical recharge time is 6-8 hours to reach 90% capacity. Key Specifications Power Capacity: 1000 VA / 600 Watts Input Voltage: 220/230 VAC Output Waveform: Simulated Sine Wave Transfer Time: 2-6 ms Battery Type: 12 V / 7 Ah x 2 Typical Backup Time: 30 minutes at 120W load Dimensions: 369 x 141 x 160 mm Weight: 10 kg Conclusion The VERTIV Liebert ITON CX 1000VA UPS is a reliable solution for power protection in small setups. The unboxing and quick test confirm its functionality and performance, making it a suitable choice for users needing uninterrupted power supply for their electronic devices. Always refer to the user manual for detailed instructions and safety precautions.

Send Message
product image
Repairing And Maintaining UPS

Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices. UPS Battery Types Lead-Acid Batteries: Valve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems. Flooded Lead Acid: Requires periodic maintenance and water topping. Lithium-Ion Batteries: Increasingly used due to longer life and higher efficiency but may require specific handling protocols. Maintenance Practices Regular Inspections: Visual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries. Connections: Ensure all terminals and connections are tight and free of corrosion. Cleaning: Clean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly. Battery Testing: Voltage Checks: Regularly measure the voltage of each battery to identify weak cells. Load Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions. Temperature Monitoring: Monitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan. Electrolyte Level (for Flooded Batteries): Check and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary. Battery Health Monitoring: Use battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health. Repair Practices Identifying Faults: Common issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems. Replacing Individual Batteries: If a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance. Equalization Charging (for Flooded Batteries): Periodically perform equalization charging to balance the charge across all cells and prevent sulfation. Reconditioning: Some lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals. Battery Replacement: When batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications. Best Practices for Maintenance Documentation: Keep records of inspections, tests, and replacements to track battery performance over time. Environmental Conditions: Maintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations. Professional Servicing: Consider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems. Training: Train personnel on proper handling, maintenance, and safety procedures related to UPS batteries. Conclusion Regular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!

Send Message
product image
Vertiv 3 Kva Single Phase Ups

The Vertiv 3 kVA single-phase UPS is designed to provide reliable power protection for small to medium-sized applications, such as servers, telecommunications equipment, and sensitive electronic devices. Here’s a comprehensive overview of its key features, specifications, and applications: Key Features Reliable Power Protection: Offers stable and clean power to protect critical equipment from surges, sags, and outages. Compact Design: Ideal for environments with limited space, easily fitting into small racks or on desktops. High Efficiency: Many models boast efficiency ratings of over 90%, reducing energy costs. User-Friendly Interface: Often includes an LCD display for easy monitoring of battery status, load levels, and UPS health. Extended Battery Life: Intelligent battery management systems help prolong battery lifespan and optimize performance. Multiple Connectivity Options: Typically includes USB and RS-232 ports for monitoring and management. Specifications (Typical Vertiv 3 kVA Model) Power Rating: 3 kVA / 2.4 kW Input Voltage: 230V single-phase Output Voltage: 230V single-phase Input Frequency: 50/60 Hz (auto-sensing) Efficiency: Generally exceeds 90% in online mode Battery Type: Typically uses valve-regulated lead-acid (VRLA) or lithium-ion batteries Form Factor: Tower configuration for easy placement Communication Interfaces: USB, RS-232, with optional SNMP for network management Applications Small Business Environments: Provides backup power for computers, POS systems, and other critical devices. Home Offices: Protects home office equipment from power disruptions. Telecommunications: Ensures the reliability of communication devices and networks. Retail Applications: Supports electronic point-of-sale systems and other sensitive electronics. Conclusion The Vertiv 3 kVA single-phase UPS is designed for reliability and efficiency, making it an excellent choice for various small to medium-sized applications. For specific models and detailed technical specifications, it's advisable to refer to the Vertiv website or contact a local distributor. If you have specific questions about a particular model or need more details, feel free to ask!

Send Message
product image
Batteries Repairing & AMC Services in Delhi

Overview: We provide specialized repairing and Annual Maintenance Contract (AMC) services for batteries ranging from 7Ah to 280Ah. Our services are designed to extend battery life, ensure optimal performance, and reduce unexpected costs. Services Offered: Battery Repair Services: Diagnostics and Testing: Comprehensive testing to identify issues such as capacity loss, internal resistance, and short circuits. Reconditioning: Techniques to restore battery capacity, including desulfation and electrolyte replenishment. Cell Replacement: Replacement of faulty cells to improve overall battery health. Sealing and Maintenance: Sealing and maintenance of battery terminals to prevent corrosion. Annual Maintenance Contracts (AMC): Regular Inspections: Scheduled inspections to monitor battery health and performance. Preventive Maintenance: Cleaning and servicing to prevent issues before they arise. 24/7 Support: Round-the-clock assistance for any battery-related emergencies. Customized Plans: AMC plans tailored to individual requirements and usage patterns. Battery Capacity Focus: Range: 7Ah to 280Ah Small Batteries (7Ah - 40Ah): Ideal for UPS systems, alarms, and backup power solutions. Medium Batteries (40Ah - 120Ah): Used in telecommunications, solar applications, and larger UPS systems. Large Batteries (120Ah - 280Ah): Suitable for industrial applications, large UPS systems, and energy storage solutions. Benefits of Our Services: Extended Battery Life: Regular maintenance and timely repairs can significantly increase battery lifespan. Cost-Effective Solutions: AMC services help prevent unexpected expenses due to battery failures. Expert Technicians: Skilled professionals with experience in handling various battery types and brands. Quick Turnaround: Efficient service delivery to minimize downtime. Safety Assurance: Adherence to safety standards during repairs and maintenance. Contact Information: For inquiries or to schedule a service, please contact us: Phone: 8744823336 Email: info@universalpower.co.in Address: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001

Send Message
product image
Amaron Quanta 12V 7AH SMF Battery in Bhagat Singh Colony Bhiwadi

The Amaron Quanta 12V 7AH SMF Battery is a high-quality battery designed for various applications, including UPS, agricultural tools, medical equipment, emergency lighting, electric wheelchairs, fire alarms, and security systems. Key Features Reliable Functionality: The battery provides reliable functionality and efficient backup for an uninterrupted power supply. Advanced AGM Valve Regulated Technology: The battery uses advanced AGM Valve Regulated technology for improved performance and reliability. Fast Charging: The 7 Ah battery is suitable for fast charging, making it ideal for applications that require quick backup. Sealed Maintenance-Free Battery: The battery is sealed and maintenance-free, reducing the need for regular maintenance and increasing its lifespan. Specifications Warranty: 12 months Weight: 1.5 kg Battery Voltage: 12 volts Dimensions: 15.1 x 6.5 x 10.1 cm Usage The Amaron Quanta 12V 7AH SMF Battery is suitable for a wide range of applications, including: Desktop/offline UPS Agricultural tools Medical equipment Emergency lighting Electric wheelchairs Fire alarms and security system applications

Send Message

Still searching for
individual desktop pcs?