Noida
+918076792323

'line power protection'

Items tagged with 'line power protection'

product image
5kva

The Vertiv Liebert GXT5 5kVA UPS is an online double-conversion uninterruptible power supply designed for critical infrastructure protection. It operates at 5kVA/5kW with user-selectable output voltages of 208V and 120V. This UPS features continuous power conditioning, ensuring that connected equipment is safeguarded against power disturbances and outages. Here are the key details: Key Features Power Rating: 5kVA / 5kW Input/Output Voltage: 208V in / 208V out (also supports 120V out) Power Factor: High power factor (0.9-1.0) allows for more connected loads, optimizing space and cost Design: Tower/rack mountable for flexible installation Remote Monitoring: Equipped with a built-in Vertiv RDU101 communications card for remote monitoring Software Support: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Runtime Options: Scalable runtime with external battery cabinets for extended backup during outages Certification: ENERGY STAR 2.0 certified for energy efficiency Display: Intuitive gravity-sensing full-color LCD display for easy status monitoring Additional Information Applications: Suitable for both centralized and edge locations, protecting critical equipment in various environments Warranty and Support: On-site service and advanced exchange service options available after remote diagnosis, ensuring quick resolution of issues Conclusion The Vertiv Liebert GXT5 5kVA UPS is a robust solution for ensuring continuous power supply and protection for critical systems, making it ideal for data centers, IT infrastructure, and other sensitive applications.

Send Message
product image
Vertiv Three Phase Online Ups

The Vertiv Online UPS systems offer a range of three-phase solutions designed for critical power applications. Here are some key models and their specifications: 1. Liebert EXS Power Rating: Up to 20 kVA Output Configuration: Configurable for three-phase (3/3) or single-phase (3/1) output Flexibility: On-site configuration allows adaptation to changing power needs Efficiency: High efficiency with double conversion technology Applications: Suitable for data centers and critical IT infrastructure 2. Liebert ITA2 Power Rating: Up to 10 kVA Design: Available in rackmount or tower configurations Reliability: Economical and efficient three-phase power for critical loads Features: High power factor and compact design 3. Liebert NX Power Rating: 40-200 kVA Scalability: Allows growth from 40 to 60 to 80 kVA, and from 80 to 100 to 120 kVA Parallel Operation: Can be paralleled for additional capacity or redundancy Efficiency: Designed for high efficiency and reliability 4. Vertiv Trinergy Power Rating: 1500-2500 kW Modular Design: High-capacity modular UPS for large applications Reliability: Maximized reliability with advanced features for critical systems 5. Liebert NXL Power Rating: Up to 800 kW Input Voltage: 480VAC, three-phase, three-wire Load Voltage: 480VAC, three-phase, three-wire in and out or four-wire in Applications: Ideal for large data centers and mission-critical environments General Features Across Models Double Conversion Technology: Ensures continuous power conditioning and protection against power disturbances High Efficiency: Designed to minimize energy costs while maximizing performance Advanced Monitoring: Many models include LCD displays for real-time monitoring and diagnostics Flexible Configurations: Options for tower or rackmount installations to suit various environments Conclusion Vertiv\'s three-phase UPS systems provide robust and reliable power protection for critical applications, ensuring the availability and integrity of essential systems in data centers and other mission-critical environments.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
UPS

The Emerson/Vertiv 1kVA UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications **Brand **: Emerson/Vertiv Model Name/Number: 1kVA UPS Capacity: 1kVA/ 0.8KW (1in - 1out) Input Voltage: 140-300VAC at 100% load; 100VAC - 300VAC on 50% load Output Voltage: 230VAC (single phase) Application Areas Small to Medium-Sized Businesses Home Offices Small Server Rooms Point of Sale (POS) Systems ATMs Medical Equipment Security Systems Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message
product image
UPS

The Vertiv Emerson Liebert Powerbank 600 1x1 6Kva Online UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications Brand: Vertiv Emerson Model Name/Number: Liebert POWERBANK 600 6KVA Online UPS Capacity: 6KVA/ 6KW (1in - 1out) Input Voltage: 76 -288VAC at 100% load; 100VAC - 288VAC on 50% load Output Voltage: 220/230/240VAC (single phase) Application Areas Edge Networks Manufacturing Units Motarised Load Jerk Load Industrial & Machine Applications Data Centers Analytical instruments Server Farms Workstations Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc., ) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message
product image
UPS

The Vertiv 5kVA online UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a user-selectable output in 208V and 120V, with a 4 -hour recharge time. Technical Specifications Load Capacity: 5000 VA, 5000 W Output Voltage: 120 V AC, 208 V AC Waveform Type: Pure Sine Wave Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds Application and Usage Data Center: Suitable for data center applications IT System: Suitable for IT system applications Mission Critical Equipment: Suitable for mission critical equipment applications Additional Features Built-in Vertiv RDU101 Communications Card: For remote monitoring and event resolution Vertiv Power Insight Software: For consolidating views of up to 100 distributed UPS units ENERGY STAR 2.0 Certified: Energy-efficient design Intuitive Gravity Sensing Full-Color LCD Display: Easy-to-use interface

Send Message
product image
Liebert Series 610 On-line UPS In Patparganj Delhi

The Liebert Series 610 On-line UPS is a true double-conversion online UPS designed for large facilities, offering a high level of reliability and flexibility. Here are its key specifications and features: Specifications: Power Rating: 225k VA to 600kVA Input Voltage: 380V to 480V AC Output Voltage: 380V to 480V AC Frequency: 50/60 Hz Efficiency: Up to 94% Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Up to 40 minutes at full load Dimensions: Varies by model Weight: Varies by model Features: High Efficiency: Up to 94% efficiency, reducing heat output and energy costs Flexibility: Modular design allows for easy expansion and customization Reliability: True double-conversion online UPS design provides high reliability and fault tolerance Scalability: Supports large facilities with high power requirements Low Heat Output: Reduces the need for complex cooling arrangements Higher DC Bus Utilization: Provides higher AC/AC and DC/AC efficiency and allows for a relatively smaller battery Applications: Enterprise Data Centers: Provides reliable power protection for large data centers Colocation/Hosting: Supports high-density colocation and hosting facilities Services: Engineering: Customized engineering services for UPS system design and implementation Installation: Professional installation services for UPS systems Preventative Maintenance: Regular maintenance services to ensure UPS system reliability Monitoring: Real-time monitoring services for UPS system performance Recycling: Environmentally responsible recycling services for UPS batteries and equipment Certifications: ISO 9001: Quality management system certification ISO 14001: Environmental management system certification ISO 45001: Occupational health and safety management system certification

Send Message
product image
VERTIV 175 TO 200 KVA ONLINE UPS IN SECTOR 82 NOIDA

overview of the Vertiv UPS models in the 175 kVA to 200 kVA range, focusing on features, specifications, and applications. General Overview Type: Online UPS (Double-Conversion) Capacity: 175 kVA to 200 kVA Form Factor: Typically available in a floor-standing configuration Electrical Specifications Input Voltage: Typically 380V to 480V AC three-phase Output Voltage: 380V to 480V AC (configurable based on application) Frequency: 50/60 Hz (auto-sensing) Output Power Factor: Usually around 0.9 to 1.0 Performance Efficiency: High efficiency, often exceeding 95% in normal operating mode, with some models offering an eco-mode for even greater energy savings. Transfer Time: Zero milliseconds due to the online architecture. Battery and Runtime Battery Type: Typically uses sealed lead-acid (SLA) or lithium-ion batteries. Battery Backup Time: Varies based on load; options for extended runtime through external battery cabinets. Recharge Time: Generally 4-8 hours to recharge from complete discharge, depending on configuration. Features LCD Display: Advanced display panel providing real-time information on operational status, battery health, load percentage, and alarms. Communication Ports: Options typically include USB, RS-232, and SNMP for monitoring and management. Surge Protection: Built-in surge protection to safeguard equipment. Overload Protection: Automatic shutdown in case of overload situations. Physical Specifications Dimensions: Varies by model; typically requires dedicated floor space. Weight: Generally heavy; ensure proper installation and support infrastructure. Installation and Management Mounting Options: Floor-mounted; requires adequate space and ventilation. Management Software: Advanced management and monitoring software available, allowing for remote control and status checks. Applications Ideal for: Data centers Critical IT infrastructure Telecommunications Industrial applications Healthcare facilities Additional Features Modularity: Some models offer modular design for scalability. Hot-Swap Capability: Allows for battery maintenance without downtime. Redundancy Options: Parallel operation capability for enhanced reliability. Warranty and Support Warranty: Typically includes a limited period covering parts and labor, with options for extended service agreements. Support: Vertiv provides various support services, including installation, maintenance, and remote monitoring. Conclusion The Vertiv UPS in the 175 kVA to 200 kVA range is designed for robust applications that require high reliability and performance. These systems are ideal for environments where uptime is critical.

Send Message

Still searching for
line power protection?