6 kva ups

The Vertiv 6 kVA UPS models, such as the Liebert GXT5 and Liebert GXT MTX+, offer robust power protection for critical equipment. Here are the key specifications and details: Vertiv Liebert GXT5 6 kVA/6 kW Model: Liebert GXT5 Capacity: 6 kVA / 6 kW Input Voltage: 208/120V Output Power Factor: 1.0 (Unity) Form Factor: Rack/Tower Dimensions: Depth: 25.6 inches Rack Height: 4U Weight: Approximately 125.60 lbs Backup/Run Time: Half Load: 9.50 minutes Full Load: 3.50 minutes Transfer Time: 0 ns (no break) Receptacle Type: Hardwired Bypass Switch: Automatic & Manual; Internal Emergency Power OFF: Yes Audible Noise: Less than 55 dBA at 1 meter Vertiv Liebert GXT MTX+ 6 kVA Model: Liebert GXT MTX+ Output Power Factor: 0.8 Input Voltage Range: 110 — 300 Vac Charging Design: 4 Stage Extendable Charging for optimized battery performance Adjustable Battery Charging Current: 1/2/4/6 Amps based on battery capacity Compact Design: Best-in-class online UPS system General Features Type: Online Double Conversion UPS Protection: Protects against outages and all types of power disturbances Applications: Suitable for centralized and edge locations, ideal for critical equipment These UPS systems are designed to ensure reliable power supply and protect sensitive electronic equipment from power disturbances, making them essential for data centers, telecommunications, and other critical applications.

Send Message
product image
UPS ( Uninterrupted Power Supplies)

UPS ( Uninterrupted Power Supplies) An uninterruptible power supply or uninterruptible power source (UPS) is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery run-time of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment. It is a type of continual power system. Features of UPS Systems: Line Interactive Range in 600VA and 2000VA with minimal battery backup. We have an online range of UPSs in 1,2 and 3 kVA category both with an internal battery backup of 10 minutes and with a longer battery backup of up to 4 hours. We offer a mini range of UPSs of capacities 6,10 and 20 kVA with options of internal isolation transformers both in single-phase and three-phase options. We have an ITA series of Hitech UPS systems in the range of 6 to 40 kVA. Hiplulse U series of UPS range with internal isolation transformers essentially meant for industrial applications.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
Battery

The Amaron Quanta 12V 160Ah SMF VRLA Battery (12AL160) is a premium sealed maintenance-free lead-acid (SMF) battery that is primarily used in applications requiring reliable and long-lasting power backup. This battery is designed for both residential and industrial use, offering a robust power supply for inverters, UPS systems, and other equipment that require stable power during outages. Here’s a detailed breakdown of its features, specifications, and applications: Key Features: Battery Type: SMF (Sealed Maintenance-Free) VRLA (Valve-Regulated Lead Acid) battery. This type of battery does not require regular water refilling, making it low-maintenance. The VRLA technology helps regulate the gas pressure inside the battery, preventing acid leakage and reducing the need for manual maintenance. Capacity: 160 Ah (Ampere-Hours), suitable for medium to high power backup applications. Provides reliable power for inverter systems and UPS (Uninterruptible Power Supply) for homes, offices, and small to medium commercial setups. Voltage: 12V – Ideal for most inverter systems, particularly those used in residential and commercial settings. Design and Construction: Sealed Design: The SMF design makes the battery spill-proof, which ensures safety even in the event of accidents or mishandling. Robust construction: The high-quality components used in the battery provide resistance to high temperatures, deep discharges, and vibration. Maintenance-Free Operation: Maintenance-Free: No need for water topping, which saves time and effort in the long run. The battery is sealed, and the use of VRLA technology ensures no need for periodic maintenance, unlike traditional flooded lead-acid batteries. Deep-Cycle Capability: Deep Discharge Tolerance: This battery can discharge deeply without compromising its lifespan, making it a good choice for areas that face frequent power outages. It is designed for applications requiring frequent cycling (discharge/recharge) without damaging the internal plates. Durability: Long life: It offers a longer life span compared to regular flat-plate lead-acid batteries. The high-performance design ensures it can withstand extreme conditions like temperature fluctuations and high heat. Safety Features: Valve Regulated: The battery is equipped with a valve to control internal gas pressure, ensuring that no dangerous gas buildup occurs. Spill-Proof: Even in the event of damage, the battery will not leak electrolyte, making it safe to install in a variety of locations. Quick Charge & High Efficiency: The Amaron Quanta 12V 160Ah battery features quick charging capabilities, making it ideal for use in environments where fast recovery is important.

Send Message
product image
battery

The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery: Specifications: Voltage: 12 volts Capacity: 9 ampere-hours (Ah) Type: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid) Dimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H) Weight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer. Terminal Type: Usually comes with F1 or F2 terminals. Operating Temperature Range: Typically between -15°C to +50°C. Cycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions. Features: Maintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping. Leak-Proof Design: The VRLA design prevents leakage, making it safer for various applications. High Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power. Deep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery. Durability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use. Applications: Uninterruptible Power Supplies (UPS): Provides backup power during outages. Electric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles. Solar Energy Storage: Can be used in solar energy systems for storing power. Emergency Lighting: Powers emergency lighting systems. Telecommunications: Used in communication equipment for backup power. Maintenance Tips: Regular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight. Proper Charging: Use a compatible charger and avoid overcharging to prolong battery life. Storage: Store in a cool, dry place and maintain a charge if not in use for extended periods. Safety Precautions: Avoid Short Circuits: Ensure terminals do not come into contact with conductive materials. Handle with Care: Batteries can be heavy; handle them carefully to avoid injury. Dispose Properly: Follow local regulations for battery disposal or recycling. For the most accurate and specific details, always refer to the manufacturer\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.

Send Message
product image
UPS

The Vertiv 10kVA UPS is a high-performance uninterruptible power supply system designed to provide continuous power conditioning and protection for mission-critical systems. It's available in various models, including the Liebert GXT5, Liebert EX L, and Liebert NX. Technical Specifications Load Capacity (VA): 10000 VA Output Voltage: 120 V AC, 208 V AC Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds 150% (impact load) minimum 200 ms Management Features Bypass Switch: Automatic & Manual, Internal Remote Monitoring: Built-in Vertiv RDU101 communications card Software: Free Vertiv Power Insight software for monitoring and management Physical Characteristics Form Factor: Tower/Rack Mount Dimensions: Not specified Weight: Not specified Certifications and Compliance ENERGY STAR 2.0 Certified: Yes Other Certifications: Not specified Additional Features Scalable Runtime Options: Matching external battery cabinets for extended runtime LCD Display: Intuitive gravity sensing full-color LCD display

Send Message
product image
UPS ( Uninterrupted Power Supplies)

The Vertiv Liebert Hipulse-U 30kVA UPS is a high-performance uninterruptible power supply designed for critical applications. Here\\\\'s an overview of the Vertiv Liebert Hipulse-U 30kVA UPS and its specifications: ** Key Features:** Online double conversion topology for high power quality and reliability 30kVA/30kW power rating with high power factor (0.9-1.0) 3-phase input and 3-phase output configuration Scalable runtime options with matching external battery cabinets ENERGY STAR 2.0 certified for energy efficiency Intuitive gravity sensing full-color LCD display Remote management capabilities with optional Vertiv RDU101 network communications card 3-year comprehensive warranty including battery with options for 2-year extension Technical Specifications: Load Capacity: VA: 30000 VA Watt: 30000 W Output Voltage: 208V AC (3-phase) 400V AC (3-phase) Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC 400/230VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds Bypass Switch: Automatic & Manual Internal Maintenance Plug/Connector Type: Terminal Block Product Overview: The Vertiv Liebert Hipulse-U 30kVA UPS is designed to protect critical equipment against outages and every type of power disturbance. This 30kVA online double conversion UPS offers continuous power conditioning in centralized and edge locations. With high power factor (0.9-1.0), it allows more connected loads saving space and costs. This tower/rack mount UPS has a built-in Vertiv RDU101 communications card for remote monitoring to help you make more informed decisions and faster event resolution. With the free Vertiv Power Insight software, you can consolidate your view of up to 100 distributed UPS units providing simple notification of status and events in a single pane of glass.

Send Message
product image
UPS

The Vertiv 6kVA UPS is a high-performance uninterruptible power supply designed for critical applications. Here\\\\'s an overview of the Vertiv 6kVA UPS and its specifications: Key Features: Online double conversion topology for high power quality and reliability 6kVA/6kW power rating with high power factor (0.9-1.0) 208V in/ 208 and 120V out single phase configuration Scalable runtime options with matching external battery cabinets ENERGY STAR 2.0 certified for energy efficiency Intuitive gravity sensing full-color LCD display Remote management capabilities with optional Vertiv RDU101 network communications card 3-year comprehensive warranty including battery with options for 2-year extension Technical Specifications: Load Capacity: VA: 6000 VA Watt: 6000 W Output Voltage: 120 V AC 208 V AC Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds Bypass Switch: Automatic & Manual Internal Maintenance Plug/Connector Type: Terminal Block Product Overview: The Vertiv Liebert GXT5 UPS is designed to protect critical equipment against outages and every type of power disturbance. This 6kVA online double conversion UPS offers continuous power conditioning in centralized and edge locations. With high power factor (0.9-1.0), it allows more connected loads saving space and costs. This tower/rack mount UPS has a built-in Vertiv RDU101 communications card for remote monitoring to help you make more informed decisions and faster event resolution. With the free Vertiv Power Insight software, you can consolidate your view of up to 100 distributed UPS units providing simple notification of status and events in a single pane of glass.

Send Message