Noida
+918076792323

'poor power quality'

Items tagged with 'poor power quality'

product image
Amaron GO BATTERY IN DELHI

Amaron GO Car Battery is one of the popular car batteries offered by Amaron, known for its reliable performance, durability, and long lifespan. Here’s a detailed overview of the Amaron GO car battery: Key Features of Amaron GO Car Battery: Technology: Advanced Lead-Acid Technology: The Amaron GO uses lead-acid technology, which is widely used for automotive batteries due to its affordability and effectiveness. HVR (High Vibration Resistance): Designed to withstand high vibrations typically found in modern vehicles, ensuring a longer life even in challenging conditions. Capacity and Voltage: The Amaron GO series offers a wide range of car battery capacities to fit different types of vehicles, typically ranging from 35Ah to 70Ah or higher, with a nominal voltage of 12V. Enhanced Performance: Long Life: Amaron GO batteries are designed for long-lasting performance, offering up to 48 months of warranty (depending on model and usage). Low Maintenance: The Amaron GO is a maintenance-free battery, meaning you don’t need to top it up with water, unlike traditional flooded lead-acid batteries. Leakproof: The battery is designed to prevent leakage, which is a common issue with old or poorly maintained batteries. Durability: Heat Resistance: The Amaron GO car batteries are built to handle extreme weather conditions, making them suitable for both hot and cold climates. Vibration Resistance: With its vibration-resistant design, the battery can last longer even in vehicles that experience high levels of vibration, such as SUVs and trucks. Quick Start Power: The Amaron GO battery is designed to provide strong cranking power for reliable engine starts, even in cold weather conditions. Its quick recharge capability allows your vehicle to return to full charge efficiently. Warranty: Warranty: Typically, the Amaron GO series comes with a 48-month warranty, including a 24-month free replacement and 24-month pro-rata. This warranty may vary depending on your region and the specific model. Applications: Personal Cars: Suitable for most types of personal vehicles like sedans, hatchbacks, and SUVs. Commercial Vehicles: Can also be used for light commercial vehicles, depending on the specific capacity and requirements. Specifications (for a typical Amaron GO battery): Voltage: 12V Capacity: 35Ah, 40Ah, 50Ah, 60Ah, 70Ah (depending on the vehicle model) Cold Cranking Amps (CCA): This varies by battery model, typically ranging from 400 to 650 CCA for vehicles that require more starting power. Warranty: 48 months (subject to terms and conditions). Dimensions: Varies by capacity, but typically around 240mm (L) x 175mm (W) x 190mm (H). Weight: Between 9kg and 20kg, depending on the capacity. Advantages: Maintenance-Free: No need to add water or perform regular maintenance. Reliability: Known for excellent reliability, ensuring consistent performance throughout the year. Long Life and Durability: High durability even in extreme conditions, with a long lifespan and reduced chances of failure. Environmentally Friendly: Made using recyclable materials and follows the necessary environmental standards. Disadvantages: Initial Cost: Amaron batteries might have a higher upfront cost compared to some budget-friendly alternatives, but their longevity and performance can make them a good value over time. Conclusion: The Amaron GO Car Battery is a great choice for vehicle owners looking for a reliable, long-lasting, and maintenance-free battery. Whether you have a compact car, an SUV, or a commercial vehicle, the Amaron GO offers excellent starting power, durability, and performance. With a strong warranty and minimal maintenance requirements, it is a solid option for anyone in need of a quality automotive battery.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Vertiv PowerBank 600 kVA Online UPS

Vertiv PowerBank 600 kVA Online UPS The Vertiv PowerBank 600 kVA Online UPS is designed for critical power applications, particularly in data centers and industrial environments. Here’s a comprehensive overview of its specifications, features, benefits, and considerations: Overview The Vertiv PowerBank 600 kVA UPS provides robust, uninterrupted power supply with advanced features for high availability, power quality, and energy efficiency. Key Specifications Power Rating: 600 kVA Input Voltage: Typically 400/415V (three-phase) Output Voltage: 400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion Efficiency: Up to 95% in normal operation and can reach 98% in eco mode Total Harmonic Distortion (THD): Typically <5% at full load Battery and Runtime Battery Type: Usually utilizes VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Configuration: Configurable based on requirements, with options for extended runtime Charging Time: Typically 4-8 hours for a full charge, depending on the battery type Runtime: Customizable based on load; options available for longer runtimes (requires additional battery packs) Features Advanced Monitoring: LCD display for real-time monitoring of status, input/output voltage, load percentage, battery status, and alarms. Redundancy: N+1 configuration for enhanced reliability and availability. Scalability: Capable of parallel operation with multiple units for increased capacity and redundancy. Smart Communication: SNMP, USB, and RS232 interfaces for remote management and monitoring. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Hot-Swap Batteries: Some configurations allow for battery replacement without turning off the UPS. Physical Characteristics Dimensions: Varies by model; typically around 120-150 cm in width and depth. Weight: Approximately 600-800 kg, depending on the configuration and battery type. Cooling: Generally air-cooled; ensure proper ventilation in the installation area. Benefits Power Quality: Provides clean, stable, and regulated power to sensitive equipment. High Availability: Designed for critical loads requiring uninterrupted power supply. Energy Efficiency: High-efficiency modes help reduce operational costs. User-Friendly: Intuitive interface and comprehensive management software facilitate easy operation. Considerations Installation: Professional installation is recommended to optimize configuration and ensure compliance with electrical standards. Maintenance: Regular inspections and battery maintenance are crucial for ensuring reliability and longevity. Environmental Conditions: Requires proper ventilation and should be installed in a climate-controlled environment to avoid overheating. Cost: Initial investment can be substantial; consider the total cost of ownership, including maintenance and energy savings. Applications Data Centers Telecommunications Infrastructure Industrial Power Applications Medical Facilities Financial Institutions Conclusion The Vertiv PowerBank 600 kVA UPS is a powerful and reliable solution for ensuring continuous power supply and protecting critical infrastructure.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
APC 6000VA UPS

The APC Smart-UPS RT 6000VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable power protection for critical equipment in various settings such as data centers, server rooms, and industrial environments. Here are some key features and specifications: Key Features: Power Capacity: 6000VA / 4800W – Suitable for medium-to-large systems that need substantial power backup. Rack-Mountable Design: The UPS can be mounted in a 19-inch rack, making it ideal for environments that require a space-efficient solution. Extended Runtime: It provides sufficient runtime to safely shut down connected equipment or continue operations during short power outages, depending on the load. Pure Sine Wave Output: Ensures high-quality power to sensitive equipment, avoiding power disturbances such as harmonic distortion or voltage spikes. Hot-Swappable Batteries: Allows for maintenance without powering down the UPS, increasing uptime and operational efficiency. LCD Display: A user-friendly LCD display provides detailed information about the UPS status, including input/output voltage, battery charge, and runtime. Extended Battery Options: Can be connected to external battery packs for increased runtime in case of prolonged power outages. Advanced Communication Features: Offers a variety of communication options such as USB, RS-232, or SNMP for monitoring and management. It’s compatible with APC’s PowerChute management software. Environmental Monitoring: Some models include environmental sensors to monitor conditions like temperature and humidity, ensuring the UPS operates in optimal conditions. Safety Features: It includes features such as overload protection, short-circuit protection, and battery optimization to ensure safe and efficient operation. Ideal Use Cases: Data Centers Server Rooms Network Equipment Industrial and Medical Equipment

Send Message
product image
Amaron Car Battery

Amaron is also known for manufacturing high-quality car batteries. Their car batteries are designed to provide reliable performance, longer life, and are known for being maintenance-free. Here's a breakdown of the key features of Amaron Car Batteries: Key Features of Amaron Car Batteries: Maintenance-Free: Most of Amaron's car batteries are maintenance-free, meaning you don't need to top up the water level regularly, making them hassle-free to use. Long Life: Amaron batteries are built for longevity. They use advanced technology in their manufacturing process to ensure they last longer than standard car batteries. High Cranking Power: Amaron batteries are designed to offer high cranking power, which is important for starting your car, especially in extreme weather conditions. Durability: Amaron batteries are built to withstand the challenges of extreme heat and cold, making them durable and reliable in all kinds of climates. Vibration Resistance: The batteries are designed to be resistant to vibrations, which is important for vehicles that are driven on rough roads. Better Performance: Amaron batteries are equipped with advanced lead-calcium alloy technology, improving the overall performance and reliability of the battery. Warranty: Amaron offers a good warranty on its car batteries, generally ranging from 24 months to 48 months, depending on the model. Types of Amaron Car Batteries: Amaron Go: A popular line for regular cars and entry-level vehicles, offering solid performance at a competitive price. Amaron Flo: Known for its low-maintenance and enhanced performance features, ideal for newer cars with more advanced electrical systems. Amaron Pro: Designed for more premium cars or those with additional electrical demands, providing extra cranking power and extended life. Amaron Quanta: A high-performance option for commercial vehicles and larger applications. Benefits: Wide Range: Amaron has a broad selection of car batteries that suit various vehicle models and sizes. Reliable Performance: Their batteries provide consistent performance and are known for being able to withstand heavy use. Low Self-Discharge Rate: These batteries maintain charge longer, even when the car isn't used for an extended period.

Send Message
product image
Vertiv 5kVA UPS

The Vertiv 5kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power for critical equipment, protecting them from power outages, surges, and other electrical disturbances. Vertiv is known for providing high-quality power management solutions, and a 5kVA UPS typically serves small to medium-sized applications such as: Server rooms Small data centers Telecommunication equipment Networking devices Medical equipment Key Features of a Vertiv 5kVA UPS: Power Capacity: 5kVA (Kilovolt-Ampere) translates to 5000 Volt-Amperes. This is roughly equivalent to 4000 watts, but the exact power capacity depends on the power factor (typically around 0.8 for UPS systems). Battery Backup: Ensures that connected equipment continues to run during power outages. The runtime depends on the load being connected and the battery capacity. Surge Protection: Provides protection against voltage spikes and surges, which can damage sensitive equipment. Voltage Regulation: The UPS can regulate incoming voltage to ensure connected devices receive consistent, safe power even if the input voltage fluctuates. Compact Design: These units are usually compact and designed to fit into standard server racks or other equipment areas. Advanced Features: Some Vertiv 5kVA models come with monitoring and management capabilities via network cards, allowing you to check the status, set alarms, or configure settings remotely. Scalability: Many Vertiv UPS systems are modular and can be expanded with additional battery packs or additional units if needed. Maintenance Bypass: Ensures continuous operation and simplifies service and maintenance tasks.

Send Message

Still searching for
poor power quality?