Noida
+918076792323

'real power depending'

Items tagged with 'real power depending'

product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Vertiv PowerBank 600 kVA Online UPS

Vertiv PowerBank 600 kVA Online UPS The Vertiv PowerBank 600 kVA Online UPS is designed for critical power applications, particularly in data centers and industrial environments. Here’s a comprehensive overview of its specifications, features, benefits, and considerations: Overview The Vertiv PowerBank 600 kVA UPS provides robust, uninterrupted power supply with advanced features for high availability, power quality, and energy efficiency. Key Specifications Power Rating: 600 kVA Input Voltage: Typically 400/415V (three-phase) Output Voltage: 400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion Efficiency: Up to 95% in normal operation and can reach 98% in eco mode Total Harmonic Distortion (THD): Typically <5% at full load Battery and Runtime Battery Type: Usually utilizes VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Configuration: Configurable based on requirements, with options for extended runtime Charging Time: Typically 4-8 hours for a full charge, depending on the battery type Runtime: Customizable based on load; options available for longer runtimes (requires additional battery packs) Features Advanced Monitoring: LCD display for real-time monitoring of status, input/output voltage, load percentage, battery status, and alarms. Redundancy: N+1 configuration for enhanced reliability and availability. Scalability: Capable of parallel operation with multiple units for increased capacity and redundancy. Smart Communication: SNMP, USB, and RS232 interfaces for remote management and monitoring. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Hot-Swap Batteries: Some configurations allow for battery replacement without turning off the UPS. Physical Characteristics Dimensions: Varies by model; typically around 120-150 cm in width and depth. Weight: Approximately 600-800 kg, depending on the configuration and battery type. Cooling: Generally air-cooled; ensure proper ventilation in the installation area. Benefits Power Quality: Provides clean, stable, and regulated power to sensitive equipment. High Availability: Designed for critical loads requiring uninterrupted power supply. Energy Efficiency: High-efficiency modes help reduce operational costs. User-Friendly: Intuitive interface and comprehensive management software facilitate easy operation. Considerations Installation: Professional installation is recommended to optimize configuration and ensure compliance with electrical standards. Maintenance: Regular inspections and battery maintenance are crucial for ensuring reliability and longevity. Environmental Conditions: Requires proper ventilation and should be installed in a climate-controlled environment to avoid overheating. Cost: Initial investment can be substantial; consider the total cost of ownership, including maintenance and energy savings. Applications Data Centers Telecommunications Infrastructure Industrial Power Applications Medical Facilities Financial Institutions Conclusion The Vertiv PowerBank 600 kVA UPS is a powerful and reliable solution for ensuring continuous power supply and protecting critical infrastructure.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message
product image
Vertiv 20 Kva Ups

The Vertiv 20 kVA UPS is typically represented by models such as the Liebert GXT5. This UPS is designed for critical applications, providing reliable power protection and ensuring the continuity of operations in environments such as data centers, telecommunications, and industrial applications. Below are the key details and specifications for the Vertiv 20 kVA UPS: Key Features Double Conversion Technology: Provides a clean and stable output voltage, protecting connected equipment from power disturbances. High Efficiency: Offers efficiencies of up to 95% in double conversion mode and even higher in eco-mode, reducing energy costs. Scalability: Modular design allows for easy scalability to meet growing power needs. Flexible Configuration: Supports various input and output configurations, making it adaptable to different environments. Advanced Monitoring and Management: Equipped with an LCD display for real-time monitoring and management of UPS status and performance. Battery Management: Intelligent battery management features extend battery life and optimize performance. Compact Design: Space-saving design suitable for various installation environments. Technical Specifications Capacity: 20 kVA / 20 kW Input Voltage: Typically supports 208 V or 400 V three-phase systems Output Voltage: Configurable options, commonly 120 V or 208 V Form Factor: Tower or rack-mounted options available Battery Type: Sealed lead-acid or lithium-ion options, depending on the model Runtime: Configurable based on battery size and load; external battery cabinets can be added for extended runtime Communication Ports: USB, RS-232, and optional SNMP for network management Applications Data Centers: Protects critical IT infrastructure from power interruptions. Telecommunications: Ensures continuous operation of communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Conclusion The Vertiv 20 kVA UPS is a reliable solution for businesses that require uninterrupted power supply and high efficiency. Its advanced features and flexible configurations make it suitable for a wide range of applications, ensuring that critical systems remain operational during power disturbances. For specific model details, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
5SC UPS

The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports. Key Specifications: Power Ratings: 500 VA to 1500 VA Output: Pure sine wave Connectivity: USB, serial, and relay Battery Type: Sealed lead-acid, maintenance-free Dimensions: Varies by model Weight: Approximately 34 lbs to 50 lbs depending on the model For more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices. Key Features: Power Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA Output Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems Battery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50% Connectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux) Display: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode Design: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR) Performance and Reliability: Run Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads Warranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment Noise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit User Experience: Setup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface Software: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead Customer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation

Send Message
product image
UPS

The Vertiv 1 kVA UPS options primarily include the Liebert GXT MT+ CX4 and Liebert GXT5 models, both designed for reliable power protection and efficiency. Liebert GXT MT+ CX4 (1 kVA): Topology: Online Double Conversion, ensuring a continuous and clean power supply. Efficiency: High efficiency ratings, typically around 94% in online mode. Input Voltage Range: Wide input voltage range to accommodate various power conditions. Battery Options: Configurable with internal and external battery options for extended runtime. Display: LCD display for real-time monitoring of UPS status and parameters. Liebert GXT5 (1 kVA): Topology: Also features Online Double Conversion for superior power quality. Efficiency: Offers up to 95% efficiency in online mode, contributing to lower operational costs. Form Factor: Compact design suitable for rack or tower configurations. Battery Management: Advanced battery management system for optimal battery performance and lifespan. Communication: Equipped with multiple communication options, including USB, RS232, and SNMP for remote monitoring. Key Features: Protection: Provides protection against power disturbances such as surges, spikes, and outages. Scalability: Can be integrated into larger systems for increased capacity and redundancy. Warranty: Typically comes with a standard warranty, often around 2 years, depending on the model and region. Support and Services: Technical Support: Vertiv offers technical support for installation, maintenance, and troubleshooting. Contact Information: Customers can reach out to Vertiv\'s support team for assistance or inquiries. This overview highlights the essential features and specifications of the Vertiv 1 kVA UPS models, suitable for various applications requiring reliable power protection.

Send Message

Still searching for
real power depending?