Noida
+918076792323

'short period'

Items tagged with 'short period'

product image
Battery

Amaron Short Tubular Batteries are a specific type of lead-acid battery designed primarily for use in inverter applications, particularly in regions with frequent power outages. These batteries are known for their durability, long life, and ability to handle deep discharge cycles. Below are the key details and specifications for Amaron Short Tubular Batteries: General Features: Design: Short tubular design allows for better space utilization and easier installation in various setups. Maintenance-Free: Many models are designed to be low-maintenance, requiring minimal attention during their lifespan. Deep Cycle Capability: Specifically engineered to handle deep discharges, making them ideal for inverter applications. Long Life: Known for their longevity, often lasting longer than conventional flat plate batteries. High Efficiency: Offers better charge acceptance and discharge performance, making them suitable for high-demand applications. Corrosion Resistance: Designed with materials that resist corrosion, enhancing the battery's lifespan. Specifications: While specific specifications can vary depending on the model, here are some common specifications for Amaron Short Tubular Batteries: Voltage: 12V Capacity: Typically ranges from 100 Ah to 220 Ah, depending on the model. Dimensions: Varies by model; common sizes include: 100 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 150 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 200 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) Weight: Generally ranges from 30 kg to 60 kg depending on capacity. Applications: Inverter Systems: Primarily used in home inverter systems for power backup. Solar Applications: Can also be used in solar power systems for energy storage. Commercial Use: Suitable for small businesses requiring reliable power backup solutions. Warranty: Amaron Short Tubular Batteries typically come with a warranty ranging from 24 to 36 months, depending on the specific model. Maintenance Tips: Water Level Check: If the battery is not maintenance-free, periodically check the electrolyte level and top up with distilled water if necessary. Terminal Cleaning: Regularly clean the battery terminals to prevent corrosion. Secure Installation: Ensure that the battery is securely mounted to prevent movement and damage. Environmental Considerations: Lead-acid batteries must be disposed of properly to prevent environmental harm. Many retailers offer recycling programs for old batteries. Conclusion: Amaron Short Tubular Batteries are a reliable choice for those needing a robust power backup solution, especially in areas with frequent power interruptions. For specific models and their detailed specifications, it is advisable to consult the manufacturer's catalog or speak with a retailer.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
4 kva ups

The Luminous Cruze+ 4kVA is a high-performance online UPS that provides uninterrupted power for residential, commercial, and IT applications. Being an online UPS, it offers continuous, stable power with zero transfer time, making it ideal for sensitive equipment such as computers, servers, medical devices, and industrial systems. Key Features of Luminous Cruze+ 4kVA UPS Online Double-Conversion Technology: The Cruze+ 4kVA uses true online double-conversion technology, which ensures that your devices get clean, continuous, and regulated power without interruptions. In case of any fluctuations in the input voltage, the UPS immediately corrects it and ensures stable output voltage. Pure Sine Wave Output: The UPS provides pure sine wave output, which is ideal for sensitive devices, as it ensures minimal distortion and avoids any damage to electronic equipment, unlike square wave UPS systems that can harm certain types of equipment. High Efficiency: With a high conversion efficiency, the Cruze+ 4kVA reduces energy consumption and operational costs. This makes it not only a reliable backup solution but also energy-efficient. Wide Input Voltage Range: The Cruze+ UPS is designed to handle a wide input voltage range, which ensures that the system performs well even in areas with frequent voltage fluctuations, thereby reducing wear and tear on both the UPS and connected devices. Long Battery Life: Equipped with advanced battery management features, this UPS helps in optimizing the battery life, offering extended service periods even with frequent use. LCD/LED Display: The LCD display shows real-time status of the UPS, including input/output voltage, battery charge status, load percentage, and any faults. The LED indicators make it easier to monitor and understand the operational status at a glance. Battery Charging: The Cruze+ 4kVA UPS can handle multiple battery types, including lead-acid and VRLA batteries. It is equipped with an intelligent charging system that ensures batteries are charged efficiently without overcharging. Overload and Short Circuit Protection: Provides overload protection and short-circuit protection, ensuring that the system is safe from potential damage during power surges or faults. Battery Bank Options: The Cruze+ 4kVA is typically paired with a separate battery bank that provides the backup power. This can include Exide tubular batteries or Luminous batteries for optimal performance. Applications Residential: For powering sensitive equipment like computers, medical devices, and other electronics. Commercial: Protects servers, networking equipment, and office devices. Industrial: Suitable for critical industrial machines, automation systems, and control panels. Technical Specifications Capacity: 4kVA (4000 VA) Input Voltage: 140V - 300V (Wide input voltage range) Output Voltage: 220V / 230V (Pure sine wave) Output Frequency: 50 Hz ± 0.2 Hz Battery Charging Current: Adjustable (Typically 5-10A) Battery Type: Compatible with VRLA, Lead-Acid, and Tubular Batteries Backup Time: Depends on the battery capacity (typically, it can provide backup for 2-4 hours depending on the load and battery bank size). Dimensions (LxWxH): 465mm x 310mm x 115mm Weight: Around 15-18 kg (excluding battery) Warranty: 2 years on the UPS (can vary based on the model or region)

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Battery

The Amaron Quanta 12V 12Ah battery is part of Amaron's lineup of high-performance lead-acid batteries, designed for various applications including uninterruptible power supply (UPS) systems, solar energy storage, and other backup power requirements. Here are the key details and specifications of the Amaron Quanta 12V 12Ah battery: 1. General Specifications: Model: Amaron Quanta 12V 12Ah Voltage: 12V (nominal) Capacity: 12Ah (Ampere-hours) Chemistry: Lead-Acid (Flooded or VRLA - Valve Regulated Lead Acid, depending on the specific model variant) Type: Sealed Lead Acid (SLA) or VRLA (Valve-Regulated Lead Acid) 2. Dimensions: Length: Approximately 151 mm Width: Approximately 65 mm Height: Approximately 94 mm Weight: Approximately 3.8 kg (8.38 lbs) 3. Applications: UPS Systems: Ideal for providing backup power to critical systems like computers, telecom equipment, and other sensitive electronics. Solar Energy Storage: Can be used in solar applications to store excess energy for later use. Electric Vehicles: Sometimes used in smaller electric vehicle or mobility scooter systems. Alarm and Security Systems: Provides backup power to alarm systems, CCTV, and other security devices. Emergency Lighting: Often used in emergency lighting setups for buildings, factories, and other premises. 4. Performance Features: Cycle Life: The Amaron Quanta 12V 12Ah battery generally offers around 300-500 charge/discharge cycles (varies based on usage, charge/discharge depth, and environmental conditions). Discharge Current: Able to provide a high discharge current (depending on load), making it suitable for short-term high-power loads. Recharge Time: Typically around 6-8 hours for a full recharge from full discharge, but this can vary depending on the charger and charging conditions. Self-Discharge Rate: Low self-discharge rate, meaning it holds charge for a long period when not in use. 5. Key Features: High Reliability: Designed for reliable performance, making it a trusted option for various backup power systems. Safety: Valve-Regulated Lead-Acid (VRLA) design, meaning it is sealed and maintenance-free under normal operating conditions. Durability: Offers robust construction for longer-lasting performance even under challenging environmental conditions. Leak-Proof Design: The VRLA design ensures that the battery is leak-resistant, which is particularly important for use in enclosed spaces. Low Maintenance: Does not require regular water refilling like traditional flooded lead-acid batteries. 6. Charging Voltage and Current: Float Voltage: Around 13.5V to 13.8V. Charge Voltage (Bulk): Typically around 14.4V to 14.7V (depending on the charger and temperature). Charge Current: Around 0.1C to 0.3C (for a 12Ah battery, this translates to a charge current of about 1.2A to 3.6A). 7. Temperature Range: Operating Temperature: Generally from -15°C to 50°C, but the optimal temperature range for performance is usually between 20°C to 25°C. Storage Temperature: For best longevity, store the battery at temperatures between 15°C to 25°C. 8. Warranty: Warranty Period: Amaron Quanta batteries typically come with a warranty period of 1-2 years, depending on the region and specific seller's terms. 9. Advantages: Cost-Effective: Amaron Quanta batteries are considered affordable yet reliable for various low to medium capacity backup systems. Wide Availability: These batteries are widely available in many regions and are popular due to their reputation for consistent performance. Maintenance-Free: VRLA technology means no need for regular maintenance, unlike flooded batteries. 10. Safety Considerations: Ventilation: While sealed, it's important to ensure that the battery is placed in a well-ventilated area to prevent the buildup of gases. Avoid Deep Discharge: Like most lead-acid batteries, it is not recommended to discharge the battery below 50% of its total capacity frequently, as this can shorten its lifespan. Proper Charging: Always use a proper charger designed for lead-acid batteries, as improper charging can lead to overcharging or undercharging, which will reduce battery life. 11. Comparison with Other Batteries: Compared to other 12V 12Ah batteries, the Amaron Quanta typically offers good cycle life, consistent performance, and a strong reputation for reliability. It is one of the more affordable options in its class, which makes it a good choice for cost-conscious consumers looking for backup power. Conclusion: The Amaron Quanta 12V 12Ah is a reliable and efficient lead-acid battery suitable for a variety of applications, from backup power systems to solar storage. It offers robust performance, minimal maintenance, and a reasonable lifespan with proper care. It's an excellent choice if you're looking for a cost-effective power solution for home or small business applications.

Send Message
product image
battery

The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery: Specifications: Voltage: 12 volts Capacity: 9 ampere-hours (Ah) Type: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid) Dimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H) Weight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer. Terminal Type: Usually comes with F1 or F2 terminals. Operating Temperature Range: Typically between -15°C to +50°C. Cycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions. Features: Maintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping. Leak-Proof Design: The VRLA design prevents leakage, making it safer for various applications. High Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power. Deep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery. Durability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use. Applications: Uninterruptible Power Supplies (UPS): Provides backup power during outages. Electric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles. Solar Energy Storage: Can be used in solar energy systems for storing power. Emergency Lighting: Powers emergency lighting systems. Telecommunications: Used in communication equipment for backup power. Maintenance Tips: Regular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight. Proper Charging: Use a compatible charger and avoid overcharging to prolong battery life. Storage: Store in a cool, dry place and maintain a charge if not in use for extended periods. Safety Precautions: Avoid Short Circuits: Ensure terminals do not come into contact with conductive materials. Handle with Care: Batteries can be heavy; handle them carefully to avoid injury. Dispose Properly: Follow local regulations for battery disposal or recycling. For the most accurate and specific details, always refer to the manufacturer\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.

Send Message
product image
Battery

The Amaron Quanta 12V 7Ah is a sealed lead-acid (SLA) battery commonly used in applications such as backup power systems, uninterruptible power supplies (UPS), security systems, and various other low-power applications. Here\'s a breakdown of its details: Key Specifications: Nominal Voltage: 12 Volts (V) Capacity: 7 Ampere-hours (Ah) at a rate of 20 hours (i.e., the battery can provide 0.35A of current for 20 hours). This is typical for deep-cycle applications, providing reliable performance over an extended period. Battery Type: Sealed Lead-Acid (SLA): Maintenance-free design. Can be installed in any orientation, though upright is recommended for optimal performance. Suitable for both float and cyclic applications. Dimensions: Length: 151 mm (5.94 inches) Width: 65 mm (2.56 inches) Height: 95 mm (3.74 inches) Weight: Approx. 2.3 kg (5.07 lbs) Terminal Type: F1 Faston connectors (0.187” wide), which are commonly used for quick connections. Operating Temperature: Discharge: -15°C to +50°C (5°F to 122°F) Charge: 0°C to +40°C (32°F to 104°F) Float Life: Typically 3-5 years in float (backup power) applications. Self-Discharge: SLA batteries typically have a low self-discharge rate of about 3-5% per month at 25°C, meaning they retain their charge relatively well when not in use for extended periods. Charge Voltage: Standard Charging Voltage: 13.5 to 13.8V (constant voltage charging) Maximum Charging Voltage: 14.4V Recommended Float Charging Voltage: 13.5V Cycle Life: Typically offers about 200-300 cycles at 100% discharge. The cycle life increases with lower depth of discharge (DoD). Applications: UPS Systems: To provide backup power for computers, networking equipment, and other devices. Solar Power Systems: As a small energy storage option in off-grid or backup solar systems. Alarm Systems: For providing power in case of a mains failure. Electric Vehicles & Mobility Scooters: In some cases for small EVs or battery-powered mobility solutions. Power Tools & Other Low Power Systems: To provide compact, reliable energy for tools and other devices. Safety & Maintenance: Maintenance-Free: No need to add water or maintain the electrolyte levels, as the battery is sealed. Overcharge Protection: Built-in mechanisms to prevent overcharging that could lead to damage or overheating. Overcurrent Protection: Built-in to prevent damage due to short circuits or excessive current. Warranty: Typically 1-2 years depending on the brand and country of purchase. Storage & Handling: Storage Temperature: Store in a cool, dry place, ideally between 15°C and 25°C. Do not store in a fully discharged state, as this can significantly reduce the lifespan of the battery. Regular Maintenance: If not in use for extended periods, check the battery voltage periodically and recharge it if necessary. The Amaron Quanta 12V 7Ah battery is designed for reliability and versatility, suitable for a variety of applications that require backup power or a small energy storage solution.

Send Message
product image
Repairing And Maintaining UPS

Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices. UPS Battery Types Lead-Acid Batteries: Valve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems. Flooded Lead Acid: Requires periodic maintenance and water topping. Lithium-Ion Batteries: Increasingly used due to longer life and higher efficiency but may require specific handling protocols. Maintenance Practices Regular Inspections: Visual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries. Connections: Ensure all terminals and connections are tight and free of corrosion. Cleaning: Clean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly. Battery Testing: Voltage Checks: Regularly measure the voltage of each battery to identify weak cells. Load Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions. Temperature Monitoring: Monitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan. Electrolyte Level (for Flooded Batteries): Check and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary. Battery Health Monitoring: Use battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health. Repair Practices Identifying Faults: Common issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems. Replacing Individual Batteries: If a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance. Equalization Charging (for Flooded Batteries): Periodically perform equalization charging to balance the charge across all cells and prevent sulfation. Reconditioning: Some lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals. Battery Replacement: When batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications. Best Practices for Maintenance Documentation: Keep records of inspections, tests, and replacements to track battery performance over time. Environmental Conditions: Maintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations. Professional Servicing: Consider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems. Training: Train personnel on proper handling, maintenance, and safety procedures related to UPS batteries. Conclusion Regular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!

Send Message

Still searching for
short period?