Noida
+918076792323

'standby power rating'

Items tagged with 'standby power rating'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
6 KVA UPS

The Vertiv 6kVA UPS models are available in both the SB (Standby) and LB (Line-Interactive) series, as well as other more advanced series, such as the On-Line (Double Conversion) series, which are designed for higher power loads and more demanding applications. Below is a breakdown of the 6kVA UPS options from Vertiv, highlighting the SB, LB, and other potential variants, including their key features, specifications, and ideal use cases. Vertiv 6kVA LB (Line-Interactive) Series UPS The LB Series for 6kVA is more advanced than the SB Series, using a Line-Interactive topology that corrects voltage fluctuations without switching to battery power. This is ideal for environments where power stability is critical, and provides more reliable protection for sensitive equipment. Key Features: Topology: Line-Interactive Power Rating: 6kVA / 6000VA Output Power: 4200W - 5400W (depending on model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (or Pure Sinewave, depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 18Ah, 24Ah, or higher (depending on model) Charging Time: 4-6 hours for full charge Backup Time (Runtime): 10-30 minutes depending on load (e.g., 50-70% load) Cooling: Fan-assisted cooling for high-efficiency operation Interfaces: USB/Serial ports (with optional software for remote monitoring and automatic shutdown) Form Factor: Tower or Rackmount (depending on specific model) Additional Features: Automatic Voltage Regulation (AVR): Helps correct voltage fluctuations (e.g., brownouts or surges) without using battery power Cold Start: Can be turned on without mains power (useful during power failures) LCD/LED Display (on some models): Real-time monitoring of UPS status, battery level, load capacity, etc. Overload, short-circuit, and low-battery protection Smart battery management to extend battery life and improve performance Audible alarms for low battery, overload, and fault events Advanced monitoring and remote management (via optional software) Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical business infrastructure Medical equipment, point-of-sale (POS) systems, and sensitive electronics requiring stable power quality IT infrastructure in small businesses needing both battery backup and protection against power fluctuations Vertiv 6kVA On-Line (Double Conversion) Series UPS The On-Line (Double Conversion) series is the most robust and efficient series, providing true double-conversion power protection. This topology is designed to offer continuous clean and stable power to sensitive equipment, protecting it from all power disturbances including blackouts, brownouts, and voltage surges. Key Features: Topology: On-Line (Double Conversion) Power Rating: 6kVA / 6000VA Output Power: 4800W - 5400W (depending on the model) Input Voltage: 110V - 300V (wide input range) Output Voltage: 230V ± 2% (pure sinewave output) Waveform Type: Pure Sinewave Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 18Ah, or 24Ah, with external battery options for longer runtimes Charging Time: 4-6 hours for full charge Backup Time (Runtime): 20-40 minutes depending on load (e.g., 50-60% load) Cooling: Advanced fan-assisted cooling with efficient heat dissipation Interfaces: USB/Serial ports, RS-232, SNMP for remote monitoring and management Form Factor: Tower or Rackmount Additional Features: Double Conversion: Provides continuous, clean power from the UPS’s inverter, ensuring zero transfer time during power disturbances High Efficiency Mode: Switches to energy-efficient operation during stable power conditions while ensuring seamless transition to double conversion during power failure LCD/LED Display: Provides real-time status of the UPS, battery health, load capacity, etc. Remote Monitoring: Integrated SNMP or optional software for proactive monitoring and automated shutdown Overload and short-circuit protection Extended Battery Options: External battery packs for longer runtime in high-demand applications

Send Message
product image
3 KVA

SB MODEL & LB MODEL The Vertiv 3kVA UPS models in the SB (Standby) and LB (Line-Interactive) series are designed to provide power protection and backup for medium-sized equipment or small-to-medium office environments, server rooms, and critical infrastructure. Below are the detailed specifications and features for each of these series in the 3kVA range. 1. Vertiv 3kVA SB (Standby) Series UPS The SB Series for 3kVA is a basic uninterruptible power supply solution. The Standby topology is typically the most cost-effective option, ideal for environments that require minimal backup time and surge protection without sophisticated power regulation. Key Features: Topology: Standby (Off-line) UPS Power Rating: 3kVA / 3000VA Output Power: 1800W - 2400W (varies by model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: Typically 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-20 minutes depending on load (e.g., 60-70% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB/Serial ports (some models include monitoring software) Form Factor: Typically Tower form factor Additional Features: Surge protection (for protection against power spikes) Overload protection and short-circuit protection Battery and overload indicators (LED and audible alarms) Optional software for remote monitoring and automatic shutdown Compact design for easier deployment in small-to-medium businesses, home offices, or workstations Ideal Use Case: Home offices and small businesses needing reliable backup power and surge protection Low power devices like workstations, point-of-sale (POS) systems, small networking equipment Environments where minimal power conditioning and voltage regulation are required 2. Vertiv 3kVA LB (Line-Interactive) Series UPS The LB Series for 3kVA uses a Line-Interactive topology, providing more advanced protection and efficiency, making it ideal for environments where power quality and stability are essential. The line-interactive design offers better Automatic Voltage Regulation (AVR), correcting voltage fluctuations without switching to battery power. Key Features: Topology: Line-Interactive Power Rating: 3kVA / 3000VA Output Power: 2100W - 2700W (varies by model) Input Voltage: 140V - 300V (wider input range compared to the SB series) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (or Pure Sinewave on some models) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: 4-6 hours to fully charge the battery Backup Time (Runtime): 10-30 minutes depending on the load (e.g., for 50-60% load) Cooling: Fan-assisted cooling Interfaces: USB/Serial ports (for monitoring and management software) Form Factor: Tower or Rackmount (depending on the specific model) Additional Features: Automatic Voltage Regulation (AVR): Corrects minor voltage fluctuations without using battery power Cold Start Capability: Can start without mains power (useful during power failures) LCD Display (on some models) to show real-time UPS status, battery level, and load information Overload, short-circuit, and low-battery protection Smart battery management for enhanced performance and extended battery life Audible alarms for power events (e.g., low battery, overload, fault) Smart monitoring and remote management with optional software for logging events and automatic shutdown during extended power outages Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical infrastructure requiring more advanced power protection Environments needing consistent power quality, such as server rooms, medical equipment, and point-of-sale systems Small businesses with sensitive equipment that requires more stable voltage levels and longer backup time

Send Message
product image
2 KVA UPS

Vertiv 2kVA UPS SB MODEL & LB MODEL The Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range: 1. Vertiv 2kVA SB (Standby) Series UPS The SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices. Key Features: Topology: Standby (Off-line) Power Rating: 2kVA / 2000VA Output Power: 1200W - 1600W (depending on model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Approximately 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB or serial ports for monitoring (depending on model) Form Factor: Typically Tower Additional Features: Surge protection Overload and short-circuit protection Low battery, overload, and fault indicators Automatic shutdown feature with optional software Audible alarms for power events (e.g., overload, low battery, fault) Compact design for easier placement in home office or small business environments Ideal Use Case: Home offices and small businesses Workstations, point-of-sale (POS) systems, and network equipment Consumer electronics that need surge protection and limited backup time 2. Vertiv 2kVA LB (Line-Interactive) Series UPS The LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology. Key Features: Topology: Line-Interactive Power Rating: 2kVA / 2000VA Output Power: 1400W - 1800W (varies by model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Around 4-6 hours to fully charge the battery Backup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown) Additional Features: Automatic Voltage Regulation (AVR) to correct voltage fluctuations Cold Start: Can be turned on without mains power (useful in power failure situations) Overload, short-circuit, and low battery protection LCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc. Enhanced battery management and energy-saving features to extend battery lifespan Audio and visual alerts for power failures, overloads, and battery issues Smart monitoring and management with optional software for power event logging and automatic shutdown Ideal Use Case: Small to medium-sized servers, workstations, and network equipment Sensitive equipment needing more precise power regulation IT infrastructures that require more consistent and reliable power protection Critical devices where frequent voltage fluctuations or outages could damage equipment Conclusion: SB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority. LB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.

Send Message
product image
1 KVA UPS

VERTIV 1kVA UPS SB MODEL & LB MODEL The Vertiv 1kVA UPS comes in various models, with common models being the SB (Standby) and LB (Line-Interactive) series. These are uninterruptible power supplies designed to provide backup power and protection for critical equipment like servers, networking devices, and other sensitive electronic systems. Let’s break down the general features and details of both SB and LB models in the 1kVA range. 1. Vertiv 1kVA SB (Standby) Series UPS The SB Series is typically a basic Standby UPS designed to offer essential protection for home office and small business applications. The main purpose of the SB UPS is to provide basic surge protection and power backup during outages. Key Features: Topology: Standby Power Rating: 1kVA / 1000VA Output Power: 600W - 800W (varies by specific model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (for typical models) Waveform Type: Simulated Sinewave (basic sinewave approximation) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries Battery Capacity: 12V, 7Ah or 9Ah (depending on model) Charging Time: Typically 4-8 hours to fully charge the battery Run Time: Provides backup power for 5-15 minutes depending on the load Interfaces: Often includes USB or serial ports for monitoring (depending on model) Form Factor: Tower type, compact design Additional Features: Surge protection Automatic voltage regulation (AVR) Overload and short-circuit protection Low battery and overload indicators Fan-assisted cooling for efficient operation Ideal Use Case: Small offices, home offices, and workstations Network routers, modems, and smaller networking equipment Low power devices and equipment 2. Vertiv 1kVA LB (Line-Interactive) Series UPS The LB Series is a more advanced line-interactive UPS system, designed for more demanding applications that require better efficiency and more consistent power quality. Key Features: Topology: Line-Interactive Power Rating: 1kVA / 1000VA Output Power: 800W - 900W (varies by specific model) Input Voltage: 140V - 300V (wider input range compared to SB) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave or Pure Sinewave (depending on the model and configuration) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 7Ah or 9Ah Charging Time: Around 4-6 hours for full charge Run Time: Offers longer backup time, depending on load (usually 10-20 minutes for 50-75% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB/Serial ports for monitoring, sometimes includes software for automatic shutdown Additional Features: Automatic Voltage Regulation (AVR) for stabilizing voltage fluctuations Enhanced battery management to extend battery life Cold start capability (UPS can start without mains power) Overload protection LCD display for real-time status monitoring (on some models) Audible alarms for low battery, overload, and fault conditions Ideal Use Case: Small to medium-sized servers, workstations, and critical network equipment Sensitive medical equipment Point-of-sale (POS) systems Small business IT infrastructure

Send Message
product image
Amaron Powerstack cells

Amaron Powerstack cells are a type of valve-regulated lead-acid (VRLA) battery designed for industrial applications. Here\\\\'s an overview of the Amaron Powerstack cells and their specifications: Key Features: Modular design for easy installation and maintenance High-performance VRLA technology for reliable power supply Low maintenance and self-discharge rate Wide operating temperature range (-20°C to 50°C) Compliance with international standards (IEC, UL, and CE) Types of Amaron Powerstack Cells: Amaron Powerstack 2V 200 Ah Cell: Capacity: 200 Ah Voltage: 2V Dimensions: 103 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 300 Ah Cell: Capacity: 300 Ah Voltage: 2V Dimensions: 123 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 400 Ah Cell: Capacity: 400 Ah Voltage: 2V Dimensions: 143 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 500 Ah Cell: Capacity: 500 Ah Voltage: 2V Dimensions: 163 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 600 Ah Cell: Capacity: 600 Ah Voltage: 2V Dimensions: 183 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 800 Ah Cell: Capacity: 800 Ah Voltage: 2V Dimensions: 203 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1000 Ah Cell: Capacity: 1000 Ah Voltage: 2V Dimensions: 223 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1200 Ah Cell: Capacity: 1200 Ah Voltage: 2V Dimensions: 243 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1500 Ah Cell: Capacity: 1500 Ah Voltage: 2V Dimensions: 263 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years Amaron Powerstack 2V 1800 Ah Cell: Capacity: 1800 Ah Voltage: 2V Dimensions: 283 x 206 x 355 mm Material: Lead-Calcium alloy Terminal Type: M8 x 25 mm Copper Design Float Life: 12 Years **Amaron Powerstack 2V 200

Send Message
product image
Amaron Quanta 12V 160Ah SMF Battery In Ajronda Chowk Faridabad

The Amaron Quanta 12V 160Ah SMF battery is a sealed maintenance-free (SMF) lead acid battery designed for various applications such as UPS systems, telecommunication equipment, fire alarm and security systems, office automation equipment, and EPAB X & electronic equipment. Product Specifications Brand: Amaron Quanta Rated Capacity: 160 Ah Warranty: 24 Months Battery Voltage: 12 V Dimensions: Not specified Weight: Not specified Material: Container & Lid: PPCP Containers with low permeability ensuring no water loss Battery Type: Lead-Acid battery with suspended electrolyte: Leak-proof Relative Humidity: Operating Relative Humidity: 0-95%, Storage Relative Humidity: 0-95% Colour: Not specified Model: Not specified Operating Environment: 0 - 40 deg C Storage Temperature: -5 - 45 deg C Output Frequency: 47 - 63 Hz Items in Pack: 1 Piece Features PPCP Containers with low permeability ensuring no water loss Proven AGM technology for maintenance-free usage Reinforced end walls ensure impact resistance Thicker grids & higher separator compression extend lifespan Inter cell weld between cells provide a high reliable, low resistance current path Unique heavy duty corrosion-resistant alloy for positive grids Overall increase in cyclic life in tropical environments Radgrid profile provides lower internal resistance Superior high discharge performance Instacharge - a patented paste recipe for excellent charge acceptance Low self-discharge rates for extended storage periods Conforms to International standards – JIS8702C Clean and Sleek looks Applications UPS System Telecommunication Equipment Fire Alarm & Security System Office Automation Equipment EPABX & Electronic Laboratory Equipment Spray machine Medical Equipment Railway Signaling Systems Other general-purpose applications Warranty 24 Months manufacturing warranty applicable 2 Year Carry In warranty from the date of sale Additional Information The battery is designed to provide efficient backup for an uninterrupted power supply and reliable standby service life. It is a preferred 12V VRLA SMF battery brand by most reputed UPS manufacturers and customers across various segments. The battery is manufactured at world-class facilities in association with Johnson Controls. The Amaron Quanta 12V 160Ah SMF battery is a reliable and efficient power backup solution for various applications.

Send Message

Still searching for
standby power rating?