Noida
+918076792323

'total isolation'

Items tagged with 'total isolation'

product image
VERTIV UPS

The Liebert APM is a modular, scalable, and flexible Uninterruptible Power Supply (UPS) system from Vertiv (formerly Emerson Network Power). It's designed to provide reliable power protection for a wide range of applications, including IT, industrial, healthcare, and telecommunication environments. The Liebert APM series comes in various power ratings, with the range you mentioned being 30 kW - 300 kW, as well as the smaller 1 to 25 kVA units, offering high flexibility for different power requirements. Key Features of the Liebert APM Series: Modular Design: One of the standout features of the Liebert APM UPS system is its modular design. This allows users to scale the system based on their current needs and future expansion. The modular units can be added incrementally, making it highly adaptable. This modular approach allows for easy maintenance and upgrades without having to replace the entire UPS unit. High Efficiency: The Liebert APM delivers high efficiency, typically achieving up to 95% or more under normal operating conditions. This efficiency helps reduce operational costs and energy consumption. It also features Eco-mode operation, which optimizes energy savings when operating in non-critical situations without compromising protection. Compact and Flexible: Despite its modular nature, the Liebert APM system has a compact design that fits easily into most data centers and industrial setups, where space can often be at a premium. It can be configured for 1-phase or 3-phase power supply, offering flexibility for different types of loads and systems. Scalable Power: The Liebert APM is available in a range from 1 kVA to 300 kVA, which makes it suitable for small server rooms to large data centers. The system allows for easy scalability by adding additional power modules as needed to meet growing demands. Flexible Battery Configurations: The UPS system supports a variety of battery configurations, allowing for customization based on your runtime requirements. You can select from different battery types, including VRLA (Valve-Regulated Lead-Acid) and lithium-ion batteries. Advanced Monitoring and Management: Liebert APM comes with Intelligent Monitoring that provides real-time data on the UPS’s performance, such as input/output voltage, battery status, and efficiency. It supports both local and remote monitoring, ensuring that technicians can be alerted to issues before they become critical problems. The system can be integrated with network management systems (NMS) for centralized control across multiple units. Dual Input Capability: Some models of the Liebert APM offer dual input power sources, providing redundancy for critical applications. This feature ensures that the system remains operational even if one power input fails. Fast Response Time: The Liebert APM offers a fast transfer time (typically in the milliseconds), ensuring that sensitive equipment is protected even during brief power outages or voltage fluctuations. Applications: Data Centers: Providing reliable, scalable power protection for server rooms and IT infrastructure. Industrial: Protecting critical manufacturing equipment and automated systems from power interruptions. Healthcare: Ensuring medical equipment, including imaging devices, lab instruments, and patient monitoring systems, remain operational during power outages. Telecommunications: Keeping communication systems up and running to ensure continuous operation of vital network infrastructure. Benefits: Scalability: The ability to scale up or down as required, which is a huge benefit for growing businesses or changing environments. Reduced Total Cost of Ownership (TCO): With high efficiency and modularity, the Liebert APM reduces energy consumption and minimizes the cost of maintenance. Reliability: Known for providing excellent protection against power issues, including surges, spikes, and outages. Customization: Supports different configurations and battery options to meet specific needs, offering flexibility across various industries. Models & Power Ratings: Small Power Ratings: For smaller environments or edge computing setups, Liebert APM models ranging from 1 kVA to 25 kVA offer robust protection without being overly complex. Large Power Ratings: For larger industrial or data center applications, the 30 kW to 300 kW versions provide scalable power protection to ensure high availability for critical operations.

Send Message
product image
Vertiv 10kVA UPS

A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers. Vertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances. Here are some key features you might find in a Vertiv 10kVA UPS: Power Capacity: 10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment. Efficiency: Many Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs. Battery Type: Typically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions. Form Factor: These systems may come in both rack-mounted or tower configurations, depending on space requirements. Scalability: Some Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity. Monitoring and Control: Advanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software. Surge Protection and Isolation: Protects your sensitive equipment from power surges, voltage spikes, and electrical noise. Maintenance Bypass: Many UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices. Vertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.

Send Message
product image
10 kW solar system installed at M3M

Universal Power team has installed a 10 kW solar system 18 panel at M3M Key Details of the Installation: Solar System Size: 10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions. Number of Panels: 18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\'s total capacity by the number of panels. 10 kW / 18 panels = approximately 555 watts per panel. This indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems. Location – M3M: M3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint. Energy Production: The energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions. In an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity. Purpose: The solar power system could be installed for various reasons: To reduce energy bills by using clean solar energy. To support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient. To provide backup power or support the grid, especially in commercial or industrial settings. Benefits of a 10 kW Solar System: Reduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time. Environmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels. Increased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs. Government Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
black hiway

Amaron Black Hiway batteries are known for their durability and performance, designed to meet the demands of various vehicles. Here’s a comprehensive overview of their features and specifications: Overview Type: Automotive batteries suitable for a range of vehicles. Technology: Advanced zero-maint enance technology for hassle-free operation. Design: Engineered for tropical climates, ensuring reliability in high temperatures. Key Specifications Capacity Options: Available in various capacities, including 80 AH, 120 AH, and 150 AH. Voltage: Standard voltage of 12 V across models. Cold Cranking Amps (CCA): High CCA ratings, such as 950 CCA for certain models, ensuring reliable starts in cold conditions. Warranty and Support Warranty Period: Typically ranges from 24 to 42 months, depending on the model. Example: 24 months full replacement + 18 months pro-rata for some models. Customer Support: Amaron provides extensive customer support for battery maintenance and inquiries. Performance Features Maintenance-Free: Designed to require no water topping up, reducing maintenance efforts. Vibration Resistance: Built to withstand harsh conditions and vibrations, enhancing longevity. High Heat Technology: Specifically designed to operate efficiently in high-temperature environments. Popular Models HC620D31R: Known for its premium quality and long life. HC180D04R: Offers a balance of performance and affordability. NT800E41R: Features a capacity of 120 AH with a total warranty of 42 months. NTX00D04R: A robust option with 150 AH capacity and high CCA. Conclusion Amaron Black Hiway batteries are a reliable choice for automotive needs, offering a combination of advanced technology, high performance, and minimal maintenance requirements, making them suitable for various driving conditions and vehicle types.

Send Message
product image
Battery

The Amaron 200Ah Current Tall Tubular Inverter Battery (AR200TT54) is a popular choice for home and small office power backup solutions. It is known for its long-lasting performance and is designed to support high power demands while offering reliable service for inverters. Here\'s a detailed breakdown of the features and specifications of this battery: Key Features: Battery Type: Tubular Lead Acid Battery – Known for better deep-cycle performance and durability as compared to flat-plate batteries. It is especially suited for areas with long and frequent power outages. Capacity: 200 Ah (Ampere-Hours) – This indicates the total charge the battery can hold, with 200 Ah being suitable for larger inverters or longer power backup requirements. Design: Tall Tubular Design – The tubular design enhances performance and life span as it offers better heat dissipation and reduces the chances of plate corrosion. Technology: Amaron\'s proprietary technology – Utilizes advanced battery design and manufacturing processes that provide greater resistance to overcharging, longer life, and higher efficiency. Maintenance: Low maintenance – The battery comes with an advanced grid technology and corrosion-resistant components, which minimizes the need for constant maintenance. Long Life: Longer battery life – The tubular design and advanced technology help extend the life of the battery compared to other types of lead-acid batteries, making it a reliable long-term investment. High Durability: Durable in high temperatures – It performs well in high-temperature conditions, making it suitable for regions with hot climates. Deep Discharge Recovery: Deep discharge tolerance – This battery can tolerate deep discharges and can recover from them effectively, making it more reliable when the power goes out for extended periods. Warranty: Typically comes with a 2-year warranty (may vary depending on the dealer or region), which ensures that the battery is protected against manufacturing defects. Performance Considerations: Backup Time: The backup time depends on the load connected to the inverter. A 200Ah battery typically supports moderate to heavy loads for up to 6-8 hours depending on inverter efficiency and power usage. Charging Time: Generally, a fully discharged 200Ah battery will take 8–12 hours to charge completely, depending on the charging system’s capacity. Applications: Home UPS Systems: Ideal for homes with moderate to heavy power usage. Inverters: Works well with most domestic and industrial inverters. Solar Systems: Can be used for off-grid and hybrid solar setups. Small Offices/Commercial Use: Suitable for locations that require a stable and reliable power backup. Pros: Long-lasting: The tubular design offers superior longevity compared to other types of batteries. Higher Charge Retention: Better charge retention ensures less frequent charging. Corrosion Resistance: Advanced technology ensures that the plates are protected from corrosion, which can extend the battery life. Cons: Weight: As a high-capacity lead-acid battery, it is heavy and might require more effort during installation. Space Requirements: It may require a bit more space compared to flat plate batteries due to its larger size. Conclusion: The Amaron AR200TT54 200Ah inverter battery is an excellent choice for those who need a high-capacity, durable, and low-maintenance backup solution. Whether you are using it for residential, commercial, or solar power applications, it provides long-term performance and reliability in all kinds of power outage scenarios.

Send Message
product image
UPS

Emerson offers a variety of Uninterruptible Power Supply (UPS) systems designed to provide reliable power protection for critical applications. Here’s an overview of their offerings: General Specifications: Types: Modular, transformerless, and line-interactive UPS systems. Input Voltage Range: Typically - Input Voltage Range: Typically 100V to 240V depending on the model. Output Voltage: Pure sine wave output for compatibility with sensitive electronic equipment. Form Factor: Available in both tower and rack-mount configurations. Key Models: 1. Emerson Liebert GXT5 Series: Ideal For: Data centers and critical IT applications. Features: High efficiency with online double-conversion technology. LCD display for real-time monitoring and diagnostics. Scalable runtime with external battery cabinets. Models: GXT5-1000RT120: 1000VA/900W GXT5-1500RT120: 1500VA/1350W GXT5-3000RT120: 3000VA/2700W 2. Emerson Liebert PSI5 Series: Features: Compact design suitable for small to medium-sized applications. USB and serial communication ports for monitoring. Built-in battery management for extended life. Models: PSI5-1000RT120: 1000VA/800W PSI5-1500RT120: 1500VA/1200W 3. Emerson Liebert APM Series: Features: Modular design for scalability and redundancy. High efficiency and low total cost of ownership. Advanced monitoring and management capabilities. Models: APM-10K: 10kVA modular UPS. APM-20K: 20kVA modular UPS. Key Features Across Models: High Efficiency: Many models offer efficiencies of 95% or higher, reducing energy costs. Advanced Monitoring: Options for remote monitoring and management through software solutions. Flexible Configuration: Supports various installation environments and requirements. Applications: Data Centers: Protects critical servers and networking equipment. Healthcare: Ensures reliable power for medical devices and systems. Industrial: Supports machinery and equipment during power interruptions. Advantages: Robust Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Scalability: Modular options allow for future expansion as power needs grow. Emerson UPS systems are designed to deliver reliable power protection and management solutions tailored to the needs of various industries, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
Battery

The Amaron Quanta 12V 12Ah battery is part of Amaron's lineup of high-performance lead-acid batteries, designed for various applications including uninterruptible power supply (UPS) systems, solar energy storage, and other backup power requirements. Here are the key details and specifications of the Amaron Quanta 12V 12Ah battery: 1. General Specifications: Model: Amaron Quanta 12V 12Ah Voltage: 12V (nominal) Capacity: 12Ah (Ampere-hours) Chemistry: Lead-Acid (Flooded or VRLA - Valve Regulated Lead Acid, depending on the specific model variant) Type: Sealed Lead Acid (SLA) or VRLA (Valve-Regulated Lead Acid) 2. Dimensions: Length: Approximately 151 mm Width: Approximately 65 mm Height: Approximately 94 mm Weight: Approximately 3.8 kg (8.38 lbs) 3. Applications: UPS Systems: Ideal for providing backup power to critical systems like computers, telecom equipment, and other sensitive electronics. Solar Energy Storage: Can be used in solar applications to store excess energy for later use. Electric Vehicles: Sometimes used in smaller electric vehicle or mobility scooter systems. Alarm and Security Systems: Provides backup power to alarm systems, CCTV, and other security devices. Emergency Lighting: Often used in emergency lighting setups for buildings, factories, and other premises. 4. Performance Features: Cycle Life: The Amaron Quanta 12V 12Ah battery generally offers around 300-500 charge/discharge cycles (varies based on usage, charge/discharge depth, and environmental conditions). Discharge Current: Able to provide a high discharge current (depending on load), making it suitable for short-term high-power loads. Recharge Time: Typically around 6-8 hours for a full recharge from full discharge, but this can vary depending on the charger and charging conditions. Self-Discharge Rate: Low self-discharge rate, meaning it holds charge for a long period when not in use. 5. Key Features: High Reliability: Designed for reliable performance, making it a trusted option for various backup power systems. Safety: Valve-Regulated Lead-Acid (VRLA) design, meaning it is sealed and maintenance-free under normal operating conditions. Durability: Offers robust construction for longer-lasting performance even under challenging environmental conditions. Leak-Proof Design: The VRLA design ensures that the battery is leak-resistant, which is particularly important for use in enclosed spaces. Low Maintenance: Does not require regular water refilling like traditional flooded lead-acid batteries. 6. Charging Voltage and Current: Float Voltage: Around 13.5V to 13.8V. Charge Voltage (Bulk): Typically around 14.4V to 14.7V (depending on the charger and temperature). Charge Current: Around 0.1C to 0.3C (for a 12Ah battery, this translates to a charge current of about 1.2A to 3.6A). 7. Temperature Range: Operating Temperature: Generally from -15°C to 50°C, but the optimal temperature range for performance is usually between 20°C to 25°C. Storage Temperature: For best longevity, store the battery at temperatures between 15°C to 25°C. 8. Warranty: Warranty Period: Amaron Quanta batteries typically come with a warranty period of 1-2 years, depending on the region and specific seller's terms. 9. Advantages: Cost-Effective: Amaron Quanta batteries are considered affordable yet reliable for various low to medium capacity backup systems. Wide Availability: These batteries are widely available in many regions and are popular due to their reputation for consistent performance. Maintenance-Free: VRLA technology means no need for regular maintenance, unlike flooded batteries. 10. Safety Considerations: Ventilation: While sealed, it's important to ensure that the battery is placed in a well-ventilated area to prevent the buildup of gases. Avoid Deep Discharge: Like most lead-acid batteries, it is not recommended to discharge the battery below 50% of its total capacity frequently, as this can shorten its lifespan. Proper Charging: Always use a proper charger designed for lead-acid batteries, as improper charging can lead to overcharging or undercharging, which will reduce battery life. 11. Comparison with Other Batteries: Compared to other 12V 12Ah batteries, the Amaron Quanta typically offers good cycle life, consistent performance, and a strong reputation for reliability. It is one of the more affordable options in its class, which makes it a good choice for cost-conscious consumers looking for backup power. Conclusion: The Amaron Quanta 12V 12Ah is a reliable and efficient lead-acid battery suitable for a variety of applications, from backup power systems to solar storage. It offers robust performance, minimal maintenance, and a reasonable lifespan with proper care. It's an excellent choice if you're looking for a cost-effective power solution for home or small business applications.

Send Message

Still searching for
total isolation?