Noida
+918076792323

'total load connected'

Items tagged with 'total load connected'

product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Battery

The Amaron 200Ah Current Tall Tubular Inverter Battery (AR200TT54) is a popular choice for home and small office power backup solutions. It is known for its long-lasting performance and is designed to support high power demands while offering reliable service for inverters. Here\'s a detailed breakdown of the features and specifications of this battery: Key Features: Battery Type: Tubular Lead Acid Battery – Known for better deep-cycle performance and durability as compared to flat-plate batteries. It is especially suited for areas with long and frequent power outages. Capacity: 200 Ah (Ampere-Hours) – This indicates the total charge the battery can hold, with 200 Ah being suitable for larger inverters or longer power backup requirements. Design: Tall Tubular Design – The tubular design enhances performance and life span as it offers better heat dissipation and reduces the chances of plate corrosion. Technology: Amaron\'s proprietary technology – Utilizes advanced battery design and manufacturing processes that provide greater resistance to overcharging, longer life, and higher efficiency. Maintenance: Low maintenance – The battery comes with an advanced grid technology and corrosion-resistant components, which minimizes the need for constant maintenance. Long Life: Longer battery life – The tubular design and advanced technology help extend the life of the battery compared to other types of lead-acid batteries, making it a reliable long-term investment. High Durability: Durable in high temperatures – It performs well in high-temperature conditions, making it suitable for regions with hot climates. Deep Discharge Recovery: Deep discharge tolerance – This battery can tolerate deep discharges and can recover from them effectively, making it more reliable when the power goes out for extended periods. Warranty: Typically comes with a 2-year warranty (may vary depending on the dealer or region), which ensures that the battery is protected against manufacturing defects. Performance Considerations: Backup Time: The backup time depends on the load connected to the inverter. A 200Ah battery typically supports moderate to heavy loads for up to 6-8 hours depending on inverter efficiency and power usage. Charging Time: Generally, a fully discharged 200Ah battery will take 8–12 hours to charge completely, depending on the charging system’s capacity. Applications: Home UPS Systems: Ideal for homes with moderate to heavy power usage. Inverters: Works well with most domestic and industrial inverters. Solar Systems: Can be used for off-grid and hybrid solar setups. Small Offices/Commercial Use: Suitable for locations that require a stable and reliable power backup. Pros: Long-lasting: The tubular design offers superior longevity compared to other types of batteries. Higher Charge Retention: Better charge retention ensures less frequent charging. Corrosion Resistance: Advanced technology ensures that the plates are protected from corrosion, which can extend the battery life. Cons: Weight: As a high-capacity lead-acid battery, it is heavy and might require more effort during installation. Space Requirements: It may require a bit more space compared to flat plate batteries due to its larger size. Conclusion: The Amaron AR200TT54 200Ah inverter battery is an excellent choice for those who need a high-capacity, durable, and low-maintenance backup solution. Whether you are using it for residential, commercial, or solar power applications, it provides long-term performance and reliability in all kinds of power outage scenarios.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
Amaron Batteries Vertiv Ups In Baghanki Manesar

Using Amaron batteries with Vertiv UPS (Uninterruptible Power Supply) systems can provide a reliable backup power solution for various applications. Here’s a comprehensive overview: Vertiv UPS Overview Purpose: Designed to ensure continuous power supply during outages, protect against power surges, and stabilize voltage fluctuations. Types: Includes models for home use, data centers, industrial applications, and more. Key Features: High Efficiency: Advanced technologies for reduced energy consumption. Modular Design: Some models allow for scalable capacity as needed. User-Friendly Interface: LCD displays show battery status, load information, and alerts. Amaron Batteries Overview Type: Generally lead-acid batteries (deep-cycle) or, in some cases, lithium-ion. Voltage Options: Commonly available in 12V, suitable for most Vertiv UPS systems. Capacity: Ranges from 46Ah to over 200Ah, depending on your backup needs. Compatibility Voltage Matching: Ensure the Amaron battery voltage (e.g., 12V) matches the UPS requirements. Capacity Selection: Choose a battery capacity that meets the total load and desired backup duration. Calculate based on the wattage of connected devices. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal to the UPS negative terminal. Ensure Secure Connections: Make sure all connections are tight to avoid arcing or power loss. Performance Benefits Extended Runtime: Higher capacity Amaron batteries can provide longer backup durations during outages. Deep Cycle Capability: Designed to handle regular deep discharges, making them ideal for UPS applications. Low Maintenance: Many Amaron batteries require minimal maintenance, offering convenience for users. Maintenance Regular Inspections: Periodically check for corrosion on terminals and ensure all connections are secure. Battery Monitoring: Use a multimeter or UPS diagnostics to check battery health and voltage levels. Signs of Replacement: Be aware of performance degradation, such as reduced backup time or inability to hold charge. Safety Precautions Adequate Ventilation: Ensure good airflow around the UPS and battery to prevent gas accumulation, especially with lead-acid batteries. Proper Charging Practices: Follow guidelines to prevent overcharging, which can damage the battery. Conclusion Pairing Amaron batteries with Vertiv UPS systems can create a robust and reliable backup power solution. This combination helps ensure your devices remain operational during power outages and protects against voltage irregularities. Always consult the user manuals for both the UPS and batteries to ensure proper installation and compatibility, maximizing the performance of your power backup system.

Send Message
product image
Amaron Batteries Numeric Ups In Khushkhera Bhiwadi

Using Amaron batteries with Numeric UPS systems can provide reliable backup power for various applications. Here’s a detailed overview of compatibility, installation, and benefits: Numeric UPS Overview Purpose: Offers backup power during outages and protects connected devices from voltage fluctuations and surges. Types: Available for home, office, and industrial applications, with models suited for different loads. Key Features: Advanced Microprocessor Control: Enhances efficiency and performance. LCD Display: Shows battery status, load level, and other important information. Wide Input Voltage Range: Handles unstable voltage conditions. Amaron Batteries Overview Type: Primarily lead-acid (deep-cycle) batteries, often maintenance-free. Voltage Options: Commonly available in 12V, suitable for Numeric UPS systems. Capacity: Ranges from 46Ah to over 200Ah, depending on your power needs. Compatibility Voltage Matching: Ensure the Amaron battery’s voltage (e.g., 12V) matches the UPS system’s requirements. Capacity Considerations: Choose a battery capacity that supports the load you plan to connect. Calculate based on the total wattage of devices and desired backup duration. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal of the battery to the UPS negative terminal. Secure Connections: Ensure all connections are tight to prevent arcing and ensure effective power transfer. Performance Benefits Extended Backup Time: Higher capacity Amaron batteries can provide longer run times during outages. Deep Cycle Capability: Designed to handle regular deep discharges, making them ideal for UPS applications. Low Maintenance Needs: Many Amaron models require minimal maintenance, enhancing convenience. Maintenance Regular Inspections: Check connections periodically for corrosion and ensure tightness. Battery Monitoring: Use a multimeter or UPS diagnostics to monitor battery health and voltage. Replacement Indicators: Be alert for signs of performance degradation, such as decreased backup time. Safety Precautions Proper Ventilation: Ensure the UPS and battery are in a well-ventilated area to prevent gas buildup, particularly with lead-acid batteries. Charging Practices: Follow guidelines to avoid overcharging, which can harm the battery. Conclusion Combining Amaron batteries with Numeric UPS systems creates a reliable backup power solution, ensuring that your devices remain protected and operational during outages. Always refer to the specific user manuals for both the UPS and the batteries for proper installation and compatibility guidelines. This pairing can significantly enhance your power reliability and efficiency.

Send Message
product image
Amaron Batteries Luminous Ups In Balawas bawal

Using Amaron batteries with Luminous UPS systems can enhance your power backup solution. Here’s a detailed overview of compatibility, installation, and benefits: Luminous UPS Overview Purpose: Provides backup power during outages and protects against voltage fluctuations. Types: Includes models for home use, office applications, and larger systems for commercial use. Key Features: Microprocessor Control: Offers advanced features for better performance. Wide Input Voltage Range: Suitable for areas with unstable voltage. LED Indicators: Show battery status, load level, and system alerts. Amaron Batteries Overview Type: Primarily lead-acid (deep-cycle) batteries, often maintenance-free. Voltage Options: Commonly available in 12V, suitable for use with Luminous UPS systems. Capacity: Ranges from 46Ah to 200Ah or more, allowing for various backup durations. Compatibility Voltage Matching: Ensure that the Amaron battery’s voltage (e.g., 12V) matches the UPS input requirements. Capacity Considerations: Select a battery capacity that meets the power demands of your connected devices and desired runtime. Calculate based on total load and expected outage duration. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal of the battery to the UPS negative terminal. Secure Connections: Make sure all connections are tight to avoid arcing and ensure efficient power transfer. Performance Benefits Extended Runtime: Higher capacity Amaron batteries can provide longer backup times, especially during prolonged outages. Durability: Amaron batteries are designed to handle deep discharges, making them ideal for UPS applications. Low Maintenance Options: Many models require minimal maintenance, simplifying user experience. Maintenance Regular Inspections: Periodically check the UPS and battery connections for corrosion and ensure tightness. Battery Monitoring: Use a multimeter or UPS diagnostics to monitor battery health and voltage. Replacement Indicators: Be aware of performance degradation signs, such as reduced backup time or inability to hold charge. Safety Precautions Ventilation: Ensure good ventilation around the UPS and battery to prevent gas accumulation, especially for lead-acid types. Charging Practices: Monitor the charging process to prevent overcharging, which can damage the battery. Conclusion Pairing Amaron batteries with Luminous UPS systems can create a robust and reliable backup power solution. Always consult the specific user manuals for both the UPS and the batteries to ensure proper installation and compatibility. This approach not only enhances your power reliability but also optimizes performance during outages.

Send Message
product image
Vertiv 3 kVA UPS In Rohini Delhi

The Vertiv 3 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection and backup for critical equipment, making it ideal for IT environments, data centers, and small to medium enterprises. Here are the key details: Specifications: Power Rating: 3 kVA (approximately 2400 watts, depending on the power factor) Input Voltage: Generally operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronic devices. Battery Type: Typically uses sealed lead-acid or lithium-ion batteries (model-dependent). Features: Automatic Voltage Regulation (AVR): Stabilizes output voltage, protecting against surges and sags. LCD Display: Provides real-time monitoring of battery status, load levels, and input/output voltage. Multiple Outlets: Usually equipped with multiple output sockets for connecting various devices. Communication Ports: USB, RS-232, or network management ports for monitoring and management via software. Hot-Swappable Batteries: Allows for battery replacement without the need to power down the UPS. Applications: IT Equipment: Ideal for servers, switches, and networking equipment. Small to Medium Enterprises: Suitable for office equipment, point-of-sale systems, and workstations. Telecommunications: Used to provide backup power for telecom equipment. Advantages: Reliable Power Backup: Ensures continuous operation during power interruptions, minimizing data loss and downtime. Compact Design: Space-efficient design for easy installation in various environments. Energy Efficiency: Many models feature energy-saving modes and high efficiency. Considerations: Battery Runtime: Assess the expected runtime based on the total load connected; higher loads will decrease runtime. Maintenance: Regular maintenance and timely battery replacements are crucial for optimal performance. Always refer to the specific model’s user manual for detailed specifications, features, and installation instructions to ensure proper use and maintenance.

Send Message
product image
VERTIV 10 kVA UPS IN SONIPAT

The Vertiv 10 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection for critical applications. Here are some key details and features typically associated with this model: Key Features: Capacity: 10 kVA (kilovolt-amperes), suitable for medium-sized data centers and IT equipment. Topologies: Double-Conversion: Offers high-level protection against power disturbances. Line-Interactive: Provides good efficiency with moderate protection. Input/Output: Input Voltage: Typically accepts a wide range (e.g., 200-240V). Output Voltage: Usually provides a pure sine wave output at 230V. Battery: Type: Sealed lead-acid or lithium-ion options. Runtime: Varies based on load; can be extended with external battery packs. Efficiency: High efficiency ratings (up to 95% or more) in online mode to reduce energy costs. Cooling: Built-in cooling fans, sometimes with temperature monitoring. Communication: USB, SNMP, or RS-232 ports for remote monitoring and management. LCD display for status updates and alerts. Form Factor: Typically available in rack-mounted or tower configurations. Safety Certifications: Compliance with relevant safety and performance standards (e.g., CE, UL). Management Software: Often bundled with software for monitoring and managing the UPS and connected devices. Applications: Data centers Telecommunications Industrial equipment Medical facilities Maintenance: Regular battery checks and replacements. Firmware updates for management software. Considerations: Determine your total load to ensure the 10 kVA capacity is adequate. Assess the physical space for installation and cooling needs. Evaluate redundancy options if necessary for mission-critical applications.

Send Message
product image
Vertiv 40Kva Online Ups In udhyog vihar Gurgaon

The Vertiv 40 kVA UPS is designed to provide robust power protection and management for critical infrastructure in data centers, IT rooms, and industrial applications. It ensures that sensitive equipment remains operational during power disturbances. Key Specifications Power Rating: 40 kVA Input Voltage: Typically 380/400/415V (three-phase) Output Voltage: 380/400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion or line-interactive Efficiency: Up to 96% in eco mode Total Harmonic Distortion (THD): <5% at full load Battery and Runtime Battery Type: Typically uses VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Capacity: Varies based on configuration; options for extended runtime Charging Time: Usually 4-8 hours for a full charge (depending on battery type) Runtime: Configurable based on load; options for longer runtimes available Features Redundancy: N+1 configuration allows for increased reliability. Scalability: Can be expanded with additional units for greater capacity or redundancy. Smart Monitoring: Advanced LCD display for real-time monitoring of UPS status, input/output voltage, load percentage, battery status, and alarms. Communication Options: SNMP, USB, RS232, and optional network management cards for remote management. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Physical Characteristics Dimensions: Varies by model; generally within 60-80 cm in width and depth Weight: Approximately 200-400 kg (depends on battery configuration) Cooling: Typically air-cooled; ensure adequate airflow in the installation environment. Benefits Power Quality: Provides clean and stable power to connected equipment. High Availability: Ensures uptime for critical loads. Flexibility: Suitable for a wide range of applications including data centers, telecommunications, and industrial systems. User-Friendly: Intuitive interface and management software for easy operation and monitoring. Considerations Installation: Professional installation recommended to ensure optimal configuration. Maintenance: Regular inspections and battery replacements are crucial for reliability. Environment: Needs proper ventilation; avoid humid or extreme temperature environments. Cost: Initial investment can be significant; consider total cost of ownership including maintenance and energy savings. Applications Data Centers IT Infrastructure Telecommunications Industrial Equipment Medical Equipment Conclusion The Vertiv 40 kVA UPS is a versatile and powerful solution for ensuring continuous power availability and protecting critical infrastructure.

Send Message

Still searching for
total load connected?