Noida
+918076792323

'ups meets'

Items tagged with 'ups meets'

product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
UPS

Vertiv Liebert PSA - 1000VA Mini Tower UPS PSA1000MT3-230U Specifications and Details The Vertiv Liebert PSA PSA1000MT3-230U is a line-interactive uninterruptible power supply (UPS) designed to provide reliable power protection for small office computers and electronic equipment. Below are the detailed specifications and features of this UPS model. Key Specifications Model: Vertiv Liebert PSA PSA1000MT3-230U Capacity: VA: 1000 VA Watts: 600 Watts Form Factor: Mini Tower Phase: Single Phase (1:1) Battery Type: Lead Acid Run Time: Typical: 5 minutes (varies with load) Warranty: 2 years Physical Dimensions Height: 234 mm Width: 147 mm Depth: 360 mm Weight: 9.5 kg Features User -Friendly LED Display: Provides easy operation and monitoring of UPS status. Socket Configuration: Multiple battery-backed and surge-protected sockets to accommodate different types of loads. Includes a mix of battery-backed and surge-only sockets. USB Communication: Comes with USB communications/shutdown software and cable for plug-and-play use. User -Replaceable Batteries: Designed for easy battery replacement to maximize the initial investment. Data Line Protection: Protects data lines to ensure the safety of connected devices. Environmental Compliance: Fully RoHS compliant, ensuring it meets environmental standards. Additional Information Input Voltage: Typically operates at 230 VAC. Output Waveform: Simulated sine wave. Runtime Performance: Provides 5 or more minutes of battery backup depending on the load level. Conclusion The Vertiv Liebert PSA PSA1000MT3-230U is an efficient and cost-effective solution for power protection in small office environments. Its combination of features, including user-friendly interfaces, multiple socket options, and easy maintenance, makes it a reliable choice for safeguarding electronic equipment against power interruptions.

Send Message
product image
UPS

The Vertiv Liebert Ita2 10 kVA is an online uninterruptible power supply (UPS) designed to provide reliable power protection for critical applications. Here are some key features and specifications: Key Features Power Capacity: 10 kVA, suitable for medium-sized equipment or applications. Phase Conversion: Can convert three-phase input to single-phase output and vice versa, making it versatile for various setups. Online Topology: Provides continuous power with no transfer time during power outages, ensuring critical systems remain operational. High Efficiency: Designed for energy efficiency, reducing operational costs while providing reliable power. Modular Design: Allows for scalability and easy maintenance. Smart Battery Management: Extends battery life and improves reliability. User-Friendly Interface: Typically includes an LCD display for monitoring and management. Communication Options: Often features various communication interfaces (USB, SNMP, etc.) for integration with monitoring systems. Applications Data centers IT infrastructure Telecommunications Medical equipment Industrial applications Considerations Installation: Ensure proper installation by qualified personnel to optimize performance and safety. Maintenance: Regular maintenance is essential for ensuring reliability and extending the lifespan of the UPS. Load Requirements: Assess the total load to determine if 10 kVA meets your needs. If you have specific questions or need more detailed information, feel free to ask!

Send Message
product image
Rental And Maintenance

Here are the key details about UPS and batteries rental and maintenance: What is UPS and Batteries Rental? UPS and batteries rental is a service that provides temporary or long-term rental of UPS systems and batteries to meet your power backup needs. This service is ideal for organizations that require a reliable power backup solution for a short period or for those who do not want to invest in purchasing a UPS system. Benefits of UPS and Batteries Rental Cost-Effective: Rental options are often more cost-effective than purchasing a UPS system, especially for short-term needs. Flexibility: Rental options provide flexibility to upgrade or downgrade your power backup solution as needed. Quick Deployment: Rental UPS systems and batteries can be quickly deployed to meet your power backup needs. Types of UPS and Batteries Rental Short-Term Rental: Rental options for a short period, typically for events or temporary power backup needs. Long-Term Rental: Rental options for an extended period, typically for organizations that require a reliable power backup solution for an extended period. Customized Rental: A tailored rental solution that meets the specific needs of your organization. What is UPS and Batteries Maintenance? UPS and batteries maintenance is a service that ensures the smooth functioning of your UPS system and batteries. This service includes regular maintenance, repairs, and replacement of parts to prevent downtime and data loss. Benefits of UPS and Batteries Maintenance Reduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss. Extended Equipment Life: Maintenance helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts. Priority Support: With a maintenance contract, you get priority support and response times, ensuring that your issues are resolved quickly. Services Covered Under UPS and Batteries Maintenance Regular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly. Repair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels. Battery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters. UPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment. Types of UPS and Batteries Maintenance Comprehensive Maintenance: Covers all maintenance, repairs, and replacement of parts. Non-Comprehensive Maintenance: Covers only maintenance and repairs, with replacement of parts at an additional cost. Customized Maintenance: A tailored maintenance solution that meets the specific needs of your organization. Why is UPS and Batteries Rental and Maintenance Important? Business Continuity: UPS and batteries rental and maintenance ensure that your business remains operational even during power outages, reducing the risk of data loss and downtime. Data Protection: Rental and maintenance services help to protect your critical data by ensuring that your UPS system and batteries are functioning properly. Equipment Protection: Rental and maintenance services help to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.

Send Message
product image
Ups Battery

UPS (Uninterruptible Power Supply) and batteries AMC (Annual Maintenance Contract) is a service agreement that ensures the smooth functioning of your UPS system and batteries. Here are the key details: What is UPS and Batteries AMC? UPS and Batteries AMC is a comprehensive maintenance program designed to ensure the reliability and performance of your UPS system and batteries. The AMC provides regular maintenance, repairs, and replacement of parts to prevent downtime and data loss. Benefits of UPS and Batteries AMC Reduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss. Extended Equipment Life: The AMC helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts. Priority Support: With an AMC, you get priority support and response times, ensuring that your issues are resolved quickly. Cost Savings: The AMC helps to reduce costs by identifying and fixing potential issues before they become major problems. Services Covered Under UPS and Batteries AMC Regular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly. Repair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels. Battery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters. UPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment. Types of UPS and Batteries AMC Comprehensive AMC: Covers all maintenance, repairs, and replacement of parts. Non-Comprehensive AMC: Covers only maintenance and repairs, with replacement of parts at an additional cost. Customized AMC: A tailored AMC that meets the specific needs of your organization. Why is UPS and Batteries AMC Important? Business Continuity: UPS and Batteries AMC ensures that your business remains operational even during power outages, reducing the risk of data loss and downtime. Data Protection: The AMC helps to protect your critical data by ensuring that your UPS system and batteries are functioning properly. Equipment Protection: The AMC helps to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.

Send Message
product image
UPS Repair

When it comes to Vertiv 10kVA UPS repair and testing, it involves several key processes to ensure that the UPS functions correctly and reliably. Below are the details regarding Vertiv 10kVA UPS repair and testing: Vertiv 10kVA UPS Repair Common Issues: Battery Failure: Batteries may degrade over time and need replacement. Inverter Problems: The inverter may fail to convert DC to AC power. Overheating: Excessive heat can damage internal components. Faulty Charging Circuit: Issues with the charging system can prevent batteries from charging properly. Software Failures: Problems with firmware can affect UPS functionality. Repair Process: Diagnosis: Use diagnostic tools to identify issues. Check for error codes or alerts on the UPS display. Component Testing: Test batteries for capacity and voltage. Inspect the inverter and charging circuits for faults. Replacement of Parts: Replace faulty batteries with new ones. Repair or replace damaged circuit boards, inverters, or other components. Calibration: Calibrate the UPS settings to ensure optimal performance. Final Testing: Conduct a load test to verify that the UPS can handle its rated capacity. Vertiv 10kVA UPS Testing Testing Procedures: Visual Inspection: Check for physical damage, loose connections, or corrosion. Battery Testing: Measure the voltage and capacity of the batteries. Conduct a discharge test to ensure batteries can hold a charge. Load Testing: Connect a load to the UPS and monitor its performance. Ensure that the UPS can supply power for the specified duration under load. Transfer Time Testing: Measure the time it takes for the UPS to switch from mains to battery power and back. Efficiency Testing: Assess the efficiency of the UPS under various loads to ensure it meets manufacturer specifications. Maintenance Recommendations Regular Maintenance: Schedule regular checks (at least annually) to ensure all components are functioning correctly. Battery Replacement: Replace batteries every 3-5 years, depending on usage and manufacturer recommendations. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and fixes. Conclusion Proper repair and testing of Vertiv 10kVA UPS systems are crucial for ensuring reliable power backup. Regular maintenance can prevent unexpected failures and extend the lifespan of the unit. If you require further details on specific models or repair services, feel free to ask!

Send Message
product image
Amaron Batteries Vertiv Ups In Baghanki Manesar

Using Amaron batteries with Vertiv UPS (Uninterruptible Power Supply) systems can provide a reliable backup power solution for various applications. Here’s a comprehensive overview: Vertiv UPS Overview Purpose: Designed to ensure continuous power supply during outages, protect against power surges, and stabilize voltage fluctuations. Types: Includes models for home use, data centers, industrial applications, and more. Key Features: High Efficiency: Advanced technologies for reduced energy consumption. Modular Design: Some models allow for scalable capacity as needed. User-Friendly Interface: LCD displays show battery status, load information, and alerts. Amaron Batteries Overview Type: Generally lead-acid batteries (deep-cycle) or, in some cases, lithium-ion. Voltage Options: Commonly available in 12V, suitable for most Vertiv UPS systems. Capacity: Ranges from 46Ah to over 200Ah, depending on your backup needs. Compatibility Voltage Matching: Ensure the Amaron battery voltage (e.g., 12V) matches the UPS requirements. Capacity Selection: Choose a battery capacity that meets the total load and desired backup duration. Calculate based on the wattage of connected devices. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal to the UPS negative terminal. Ensure Secure Connections: Make sure all connections are tight to avoid arcing or power loss. Performance Benefits Extended Runtime: Higher capacity Amaron batteries can provide longer backup durations during outages. Deep Cycle Capability: Designed to handle regular deep discharges, making them ideal for UPS applications. Low Maintenance: Many Amaron batteries require minimal maintenance, offering convenience for users. Maintenance Regular Inspections: Periodically check for corrosion on terminals and ensure all connections are secure. Battery Monitoring: Use a multimeter or UPS diagnostics to check battery health and voltage levels. Signs of Replacement: Be aware of performance degradation, such as reduced backup time or inability to hold charge. Safety Precautions Adequate Ventilation: Ensure good airflow around the UPS and battery to prevent gas accumulation, especially with lead-acid batteries. Proper Charging Practices: Follow guidelines to prevent overcharging, which can damage the battery. Conclusion Pairing Amaron batteries with Vertiv UPS systems can create a robust and reliable backup power solution. This combination helps ensure your devices remain operational during power outages and protects against voltage irregularities. Always consult the user manuals for both the UPS and batteries to ensure proper installation and compatibility, maximizing the performance of your power backup system.

Send Message
product image
Amaron Batteries Luminous Ups In Balawas bawal

Using Amaron batteries with Luminous UPS systems can enhance your power backup solution. Here’s a detailed overview of compatibility, installation, and benefits: Luminous UPS Overview Purpose: Provides backup power during outages and protects against voltage fluctuations. Types: Includes models for home use, office applications, and larger systems for commercial use. Key Features: Microprocessor Control: Offers advanced features for better performance. Wide Input Voltage Range: Suitable for areas with unstable voltage. LED Indicators: Show battery status, load level, and system alerts. Amaron Batteries Overview Type: Primarily lead-acid (deep-cycle) batteries, often maintenance-free. Voltage Options: Commonly available in 12V, suitable for use with Luminous UPS systems. Capacity: Ranges from 46Ah to 200Ah or more, allowing for various backup durations. Compatibility Voltage Matching: Ensure that the Amaron battery’s voltage (e.g., 12V) matches the UPS input requirements. Capacity Considerations: Select a battery capacity that meets the power demands of your connected devices and desired runtime. Calculate based on total load and expected outage duration. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal of the battery to the UPS negative terminal. Secure Connections: Make sure all connections are tight to avoid arcing and ensure efficient power transfer. Performance Benefits Extended Runtime: Higher capacity Amaron batteries can provide longer backup times, especially during prolonged outages. Durability: Amaron batteries are designed to handle deep discharges, making them ideal for UPS applications. Low Maintenance Options: Many models require minimal maintenance, simplifying user experience. Maintenance Regular Inspections: Periodically check the UPS and battery connections for corrosion and ensure tightness. Battery Monitoring: Use a multimeter or UPS diagnostics to monitor battery health and voltage. Replacement Indicators: Be aware of performance degradation signs, such as reduced backup time or inability to hold charge. Safety Precautions Ventilation: Ensure good ventilation around the UPS and battery to prevent gas accumulation, especially for lead-acid types. Charging Practices: Monitor the charging process to prevent overcharging, which can damage the battery. Conclusion Pairing Amaron batteries with Luminous UPS systems can create a robust and reliable backup power solution. Always consult the specific user manuals for both the UPS and the batteries to ensure proper installation and compatibility. This approach not only enhances your power reliability but also optimizes performance during outages.

Send Message
product image
Amaron Batteries Apc Ups In Sector 53 Noida

Using Amaron batteries with APC (American Power Conversion) UPS (Uninterruptible Power Supply) systems can provide reliable backup power. Here’s a comprehensive overview of how to pair them effectively: APC UPS Overview Purpose: Provides emergency power during outages and stabilizes voltage fluctuations. Types: Ranges from consumer models to enterprise-level systems. Key Features: Automatic Voltage Regulation (AVR): Stabilizes voltage. Surge Protection: Protects connected devices from surges. LCD Display: Displays battery status, load level, and other metrics. Amaron Batteries Overview Type: Typically lead-acid (both conventional and maintenance-free) or possibly lithium-ion for some applications. Voltage Options: Commonly available in 12V configurations, suitable for UPS systems. Capacity: Various capacities (e.g., 46Ah, 100Ah, 150Ah), depending on the UPS model and required backup time. Compatibility Sizing: Ensure the Amaron battery’s voltage matches the UPS system (e.g., a 12V battery for a 12V UPS). Capacity Matching: Choose a battery capacity that meets or exceeds the UPS\\\\'s requirements for runtime during power outages. Calculate based on the load you wish to support. Installation Connection: Connect the Amaron battery to the UPS according to the manufacturer\\\\'s instructions. Typically, you\\\\'ll connect the positive (+) terminal to the UPS\\\\'s positive input and the negative (-) terminal to the negative input. Securing: Ensure that all connections are tight and secure to prevent arcing or disconnections. Performance and Benefits Extended Runtime: Using higher-capacity Amaron batteries can extend the runtime of the UPS during power outages. Reliability: Amaron batteries are known for their durability and ability to handle deep discharges, making them suitable for UPS applications. Maintenance-Free Options: Many Amaron batteries are designed to be maintenance-free, reducing the need for regular upkeep. Maintenance Regular Checks: Periodically inspect the UPS and battery connections for corrosion and tightness. Battery Health: Monitor the battery’s voltage and overall health using a multimeter or UPS diagnostics. Replacement: Replace the battery as needed based on performance degradation or if the battery shows signs of failure. Safety Precautions Ventilation: Ensure proper ventilation during operation to prevent gas buildup, especially with lead-acid batteries. Overcharging: Monitor charging cycles to prevent overcharging, which can lead to battery damage. Conclusion Combining Amaron batteries with APC UPS systems can enhance your power reliability and provide an effective backup solution. Always refer to the specific user manuals for both the UPS and batteries to ensure compatibility and proper installation procedures.

Send Message