Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +918744823336 (International callers) or +918744823336 (Indian callers).
The Exide 12V 18Ah SMF (Sealed Maintenance Free) battery is a robust option for various applications like UPS systems, solar energy systems, and emergency backup power. Here are the key details:
Specifications:
Voltage: 12 Volts
Capacity: 18 Ah (Ampere-hours)
Type: Sealed Maintenance Free (SMF)
Chemistry: Lead-acid (VRLA - Valve Regulated Lead Acid)
Dimensions: Approximately 181 mm (L) x 77 mm (W) x 167 mm (H) (dimensions may vary slightly by model)
Weight: Around 5.5 to 6.0 kg
Features:
Maintenance-Free: No need for electrolyte checks or water refills.
Leak-Proof Design: Safe for use in various positions without leakage.
Long Service Life: Designed for durability and reliable performance.
High Discharge Rate: Suitable for applications requiring rapid power delivery.
Applications:
Uninterruptible Power Supplies (UPS)
Solar power systems
Emergency lighting systems
Security systems
Small electric vehicles and scooters
Charging Recommendations:
Charging Voltage: Typically between 14.4 to 15.0 volts.
Charging Current: Should not exceed 1.8A for optimal battery health.
Storage and Maintenance:
Store in a cool, dry environment.
Maintain a full charge if not in use for extended periods.
Regularly check for any signs of damage or wear.
Safety Precautions:
Avoid short-circuiting terminals.
Handle with care to prevent damage.
Follow all manufacturer instructions for safe operation.
For precise details and specifications, always refer to the specific product datasheet or manufacturer guidelines relevant to your model.
The SF Sonic Pro Tubular batteries are designed for a range of applications, particularly for inverter and solar power systems. Here are some key details:
Features:
Design: Tubular design allows for better charge retention and longer life.
Maintenance: Generally, they require periodic topping up with distilled water.
Durability: Designed to withstand deep discharge cycles, making them suitable for frequent use.
Capacity: Available in various amp-hour (Ah) ratings to suit different power needs.
Specifications:
Voltage: Typically available in 12V.
Construction: Lead-acid technology, often with a corrosion-resistant design.
Applications: Used in solar systems, inverters, and other renewable energy setups.
Advantages:
Longer Life Cycle: Tubular batteries generally have a longer lifespan compared to flat plate batteries.
Efficiency: Good charging efficiency and performance under load.
Cost-Effective: Offers a good balance between initial cost and lifespan.
Maintenance Tips:
Regularly check the electrolyte levels and top up as necessary.
Clean terminals to prevent corrosion.
Ensure proper ventilation during charging.
Applications:
Home solar power systems
Uninterrupted power supply (UPS) systems
Industrial applications where consistent power is needed
SF Sonic Pro Tubular Batteries In Ashok Vihar Sonipat
The Vertiv 3 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection and backup for critical equipment, making it ideal for IT environments, data centers, and small to medium enterprises. Here are the key details:
Specifications:
Power Rating: 3 kVA (approximately 2400 watts, depending on the power factor)
Input Voltage: Generally operates within a range of 160-300 VAC.
Output Voltage: Commonly 220/230/240 VAC.
Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronic devices.
Battery Type: Typically uses sealed lead-acid or lithium-ion batteries (model-dependent).
Features:
Automatic Voltage Regulation (AVR): Stabilizes output voltage, protecting against surges and sags.
LCD Display: Provides real-time monitoring of battery status, load levels, and input/output voltage.
Multiple Outlets: Usually equipped with multiple output sockets for connecting various devices.
Communication Ports: USB, RS-232, or network management ports for monitoring and management via software.
Hot-Swappable Batteries: Allows for battery replacement without the need to power down the UPS.
Applications:
IT Equipment: Ideal for servers, switches, and networking equipment.
Small to Medium Enterprises: Suitable for office equipment, point-of-sale systems, and workstations.
Telecommunications: Used to provide backup power for telecom equipment.
Advantages:
Reliable Power Backup: Ensures continuous operation during power interruptions, minimizing data loss and downtime.
Compact Design: Space-efficient design for easy installation in various environments.
Energy Efficiency: Many models feature energy-saving modes and high efficiency.
Considerations:
Battery Runtime: Assess the expected runtime based on the total load connected; higher loads will decrease runtime.
Maintenance: Regular maintenance and timely battery replacements are crucial for optimal performance.
Always refer to the specific model’s user manual for detailed specifications, features, and installation instructions to ensure proper use and maintenance.
The Vertiv 2 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protection for various electronic devices, making it suitable for both IT and industrial applications. Here are the key details:
Specifications:
Power Rating: 2 kVA (approximately 1600 watts, depending on the power factor)
Input Voltage: Typically operates within a range of 160-300 VAC.
Output Voltage: Commonly 220/230/240 VAC.
Output Waveform: Pure sine wave for compatibility with sensitive equipment.
Battery Type: Generally sealed lead-acid or lithium-ion (varies by model).
Features:
Automatic Voltage Regulation (AVR): Protects against voltage fluctuations by stabilizing the output.
LCD Display: Provides real-time data on battery status, load level, and input/output voltage.
Multiple Outlets: Usually includes several output sockets for connecting multiple devices.
Communication Ports: USB, RS-232, or network management options for monitoring and management.
Hot-Swappable Batteries: Enables battery replacement without shutting down the UPS.
Applications:
IT Infrastructure: Ideal for servers, networking equipment, and critical computing systems.
Small to Medium Enterprises: Suitable for point-of-sale systems, office equipment, and telecommunications.
Industrial Use: Can be used for powering essential equipment in various industrial settings.
Advantages:
Reliable Backup Power: Ensures continuity during power outages, preventing data loss and downtime.
Compact and Efficient: Designed for easy installation and energy efficiency.
Scalability: Can be used in conjunction with other UPS systems for larger setups.
Considerations:
Battery Runtime: Evaluate the expected runtime based on the connected load; larger loads will reduce runtime.
Maintenance: Regular maintenance checks and timely battery replacements are essential for performance.
Always consult the specific model’s user manual for detailed specifications, features, and installation instructions tailored to your needs.
The Vertiv 1 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and surge protection for various electronic devices and systems. Here are the key details:
Specifications:
Power Rating: 1 kVA (approximately 800 watts)
Input Voltage: Typically 160-300 VAC (check specific models for exact range)
Output Voltage: 220/230/240 VAC (configurable depending on the model)
Output Waveform: Pure sine wave (for many models), ensuring compatibility with sensitive equipment.
Battery Type: Usually sealed lead-acid or lithium-ion (depending on the model).
Features:
Automatic Voltage Regulation (AVR): Stabilizes output voltage and protects against power fluctuations.
LCD Display: Provides real-time information on battery status, load level, and input/output voltage.
Multiple Outlets: Typically features several output sockets for connecting devices.
Communication Ports: USB and/or serial ports for monitoring and management through software.
Hot-Swappable Batteries: Allows battery replacement without shutting down the UPS.
Applications:
IT Equipment: Ideal for servers, networking equipment, and workstations.
Home Office: Suitable for personal computers, routers, and home office equipment.
Small Business: Provides backup for point-of-sale systems and other essential devices.
Advantages:
Reliable Backup Power: Ensures continuous power during outages, preventing data loss and equipment damage.
Compact Design: Space-saving design for easy installation in various environments.
Energy Efficient: Many models feature energy-saving modes to reduce power consumption.
Considerations:
Battery Runtime: Check the battery runtime specifications based on the load connected.
Maintenance: Regular checks and battery replacements may be necessary to ensure optimal performance.
Always refer to the specific model\\\\'s manual for detailed specifications, features, and installation instructions.
The Amaron Quanta 12V 18Ah battery is a popular choice for various applications, particularly in the field of backup power and renewable energy systems. Here are the key details:
Specifications:
Type: Lead-acid battery (VRLA - Valve Regulated Lead Acid)
Voltage: 12 Volts
Capacity: 18 Amp-hours (Ah)
Dimensions: Typically around 181 x 77 x 167 mm (length x width x height), but check specific models for exact measurements.
Weight: Approximately 5-6 kg (varies by manufacturer).
Features:
Maintenance-Free: Designed to be low maintenance due to the sealed construction.
Long Life: Good cycle life and longevity, suitable for deep discharge applications.
Vibration Resistance: Built to withstand vibrations, making it suitable for various environments.
Wide Temperature Range: Operates effectively in a broad temperature range.
Applications:
UPS Systems: Ideal for uninterruptible power supply applications.
Solar Systems: Commonly used in solar energy storage setups.
Electric Vehicles: Suitable for powering electric scooters and bikes.
Backup Power: Reliable for backup in residential and commercial setups.
Advantages:
Deep Discharge Capability: Can handle deep cycles, making it suitable for applications where full discharge is common.
High Performance: Provides stable voltage and reliable performance over time.
Eco-Friendly: Recyclable materials used in manufacturing.
Considerations:
Charging: Use a compatible charger to avoid overcharging or damaging the battery.
Discharge Rate: Be mindful of the discharge rates as it can impact battery life.
Always refer to the manufacturer\\\\'s manual for detailed instructions on usage, charging, and maintenance.
Amaron Quanta 12V 18Ah battery In Raj Nagar Extension Ghaziabad
The Amaron Quanta 12V 120Ah SMF battery is a Sealed Maintenance Free (SMF) VRLA battery designed for UPS applications. It has a nominal voltage of 12 volts and a rated capacity of 120 Ah .
Product Details:
Capacity: 12V 120Ah
Battery Type: SMF (Sealed Maintenance Free)
Brand: Amaron
Filled Weight: 30.0 kg
Dimensions: 483x171x220 mm
Battery Voltage: 12 V
Item Code: 12AL120
Items in Pack: 1 Piece
Key Features:
Reliable power and long-lasting performance
Maintenance-free operation
Ideal for UPS and inverter applications
ECO Friendly
Advanced AGM Valve Regulated technology
Lowest carbon footprint
Suitable for Fast charging
Sealed maintenance-free battery
Standby Use and Cyclic Use:
Standby Use: Charging Voltage 13.5V/Battery
Cyclic Use: Charging Voltage 13.8V/Battery
Warranty:
Warranty Period: 24 months
Warranty Details: 24 months manufacturing warranty applicable
Amaron Quanta 12V 120Ah SMF battery In Sector 3 Bawal
The Amaron Quanta 12V 65Ah SMF battery is a Sealed Maintenance Free (SMF) VRLA battery designed for UPS applications. It has a nominal voltage of 12 volts and a rated capacity of 65 Ah .
Product Details:
Capacity: 12V 65Ah
Battery Type: SMF (Sealed Maintenance Free)
Brand: Amaron
Filled Weight: 20.0 kg
Dimensions: 351x167x175 mm
Battery Voltage: 12 V
Item Code: 12AL065
Items in Pack: 1 Piece
Key Features:
Reliable power and long-lasting performance
Maintenance-free operation
Ideal for UPS and inverter applications
ECO Friendly
Advanced AGM Valve Regulated technology
Lowest carbon footprint
Suitable for Fast charging
Sealed maintenance-free battery
Standby Use and Cyclic Use:
Standby Use: Charging Voltage 13.5V/Battery
Cyclic Use: Charging Voltage 13.8V/Battery
Warranty:
Warranty Period: 24 months
Warranty Details: 24 months manufacturing warranty applicable
Amaron Quanta 12V 65Ah SMF battery In Alwar Road Bhiwadi
The Amaron Quanta 12V 42Ah SMF battery is a Sealed Maintenance Free (SMF) VRLA battery designed for UPS applications. It has a nominal voltage of 12 volts and a rated capacity of 42 Ah .
Product Details:
Capacity: 12V 42Ah
Battery Type: SMF (Sealed Maintenance Free)
Brand: Amaron
Filled Weight: 14 kg
Dimensions: 199x167x175 mm
Battery Voltage: 12 V
Item Code: 12AL042
Items in Pack: 1 Piece
Key Features:
Reliable power and long-lasting performance
Maintenance-free operation
Ideal for UPS and inverter applications
ECO Friendly
Advanced AGM Valve Regulated technology
Lowest carbon footprint
Suitable for Fast charging
Sealed maintenance-free battery
Standby Use and Cyclic Use:
Standby Use: Charging Voltage 13.5V/Battery
Cyclic Use: Charging Voltage 13.8V/Battery
Amaron Quanta 12V 42Ah SMF battery In Ghazipur Faridabad
The Amaron Quanta 12V 9Ah SMF battery is a Sealed Maintenance Free (SMF) VRLA battery designed for UPS applications. It has a nominal voltage of 12 volts and a rated capacity of 9 Ah .
Product Details:
Capacity: 12V 9Ah
Battery Type: SMF (Sealed Maintenance Free)
Brand: Amaron
Filled Weight: 1.5 kg
Warranty: 12 months offsite warranty
Country of Origin: Made in India
Dimensions: 15.1 x 6.5 x 10.1 cm
Battery Voltage: 12 V
Item Code: 12AVL009
Items in Pack: 1 Piece
Key Features:
Reliable power and long-lasting performance
Maintenance-free operation
Ideal for UPS and inverter applications
ECO Friendly
Advanced AGM Valve Regulated technology
Lowest carbon footprint
Suitable for Fast charging
Sealed maintenance-free battery
Other Options:
Amaron Quanta 12V 7Ah SMF battery: This battery has a lower capacity of 7Ah and is also suitable for UPS and inverter applications.
Amaron Quanta 12V 18Ah SMF battery: This battery has a higher capacity of 18Ah and is also suitable for UPS and inverter applications.
Other capacities and types of Amaron Quanta batteries are also available.
Please note that the exact specifications and features of the Amaron Quanta 12V 9Ah SMF battery may vary depending on the supplier and the specific product.
Amaron Quanta 12V 9Ah SMF battery In Sector 102 Noida
The Amaron Quanta 12V 28Ah SMF battery is a Sealed Maintenance Free (SMF) VRLA battery designed for UPS applications. It has a nominal voltage of 12 volts and a rated capacity of 28 Ah .
Product Details:
Capacity: 12V 28Ah
Battery Type: SMF (Sealed Maintenance Free)
Brand: Amaron
Filled Weight: Not specified
Warranty: Not specified
Country of Origin: Made in India
Key Features:
Reliable power and long-lasting performance
Maintenance-free operation
Ideal for UPS and inverter applications
Other Options:
Amaron Quanta 12V 65Ah SMF battery: This battery has a higher capacity of 65Ah and is also suitable for UPS and inverter applications.
Other capacities and types of Amaron Quanta batteries are also available, including 100Ah and 150Ah options.
Please note that the exact specifications and features of the Amaron Quanta 12V 28Ah SMF battery may vary depending on the supplier and the specific product.
Amaron Quanta 12V 28Ah SMF Battery In Sultanpur Gurgaon
Here\\\\'s a comprehensive guide to repairing Vertiv and Liebert online UPS systems:
Preparation
Before starting the repair process, ensure you have the necessary tools, documentation, and safety precautions in place. Familiarize yourself with the UPS system\\\\'s electrical and mechanical components.
Tools and Equipment
Multimeter
Screwdrivers (flathead and Phillips)
Torx driver (for some models)
Wire strippers
Pliers and wrenches
Safety glasses and gloves
Anti-static wrist strap or mat
Safety Precautions
Ensure the UPS system is turned off and unplugged from the power source.
Verify the system is properly grounded.
Wear protective gear, including safety glasses and gloves.
Avoid touching electrical components or wires.
Common Faults and Repairs
Faulty Battery
Symptoms: UPS not holding charge, frequent shutdowns, or battery failure.
Repair: Replace the faulty battery with a new one of the same type and rating.
Power Module Failure
Symptoms: UPS not functioning, error messages, or overheating.
Repair: Replace the faulty power module with a new one of the same type and rating.
Control Board Failure
Symptoms: UPS not functioning, error messages, or erratic behavior.
Repair: Replace the faulty control board with a new one of the same type and rating.
Fan Failure
Symptoms: Overheating, noise, or reduced airflow.
Repair: Replace the faulty fan with a new one of the same type and rating.
Capacitor Failure
Symptoms: UPS not functioning, error messages, or overheating.
Repair: Replace the faulty capacitor with a new one of the same type and rating.
Repair Procedures
Disassembly
Remove the UPS system\\\\'s outer casing and any internal components to access the faulty part.
Document the wiring and connections before disconnecting them.
Component Replacement
Remove the faulty component and replace it with a new one of the same type and rating.
Ensure proper connections and wiring.
Reassembly
Reassemble the UPS system in the reverse order of disassembly.
Ensure all connections and wiring are secure.
Testing and Verification
Visual Inspection
Verify all components are properly installed and connected.
Check for any signs of physical damage or wear.
Functional Testing
Turn on the UPS system and verify it\\\\'s functioning correctly.
Test the system under various load conditions.
Performance Verification
Verify the UPS system\\\\'s performance meets the manufacturer\\\\'s specifications.
Check for any error messages or alarms.
Documentation and Record-Keeping
Repair Log
Document the repair process, including the faulty component, replacement part, and any challenges encountered.
Include before-and-after photos or videos.
System Configuration
Update the UPS system\\\\'s configuration and settings, if necessary.
Verify the system is properly configured and functioning correctly.
Additional Tips and Recommendations
Manufacturer\\\\'s Documentation
Consult the manufacturer\\\\'s documentation and repair guides for specific instructions and recommendations.
Training and Certification
Consider obtaining training and certification from the manufacturer or a reputable third-party organization.
Preventive Maintenance
Regularly perform preventive maintenance tasks to minimize the risk of future repairs.
By following this guide, you\\\\'ll be able to repair your Vertiv or Liebert online UPS system efficiently and effectively. Remember to always follow safety precautions and manufacturer\\\\'s recommendations to ensure a successful repair.