DELTA HPH Series, Three Phase, 20/30/40/60/80/100/120 kW
Best-in-class power protection with maximum power and cost efficiency
The Ultron HPH is a true online double-conversion UPS offering the best-in-class combination of maximum available power, unbeatable energy efficiency and superior power performance for small data centers and other mission critical applications. With fully rated power (kVA=kW), the Ultron HPH provides maximum available power without de-rating the UPS. Thanks to the three level IGBT topology for both PFC (power factor correction) and inverter, the Ultron HPH features up to 96% AC-AC efficiency. Delta’s advanced digital PFC control also contributes low iTHD < 3% and high input power factor > 0.99 resulting in significant TCO (Total Cost of Ownership) savings. Facilitating increased availability and power performance, the Ultron HPH is an ideal solution for protecting your mission critical operations.
Features & Benefits
Best-in-Class Power Performance and Efficiency
Fully rated power (kVA=kW) for maximum power availability
Leading AC-AC efficiency up to 96% saves energy costs
Low harmonic pollution (iTHD<3%) & high input power factor (>0.99) reduce upstream investment costs
Assured Reliability
Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
DSP based technology enables reduction in the number of electronic components to lower failure rate
Redundant auxiliary power and fan design* enhance system reliabil
* Applied for models HPH-60/80/100/120K
Watch-dog design of dual auxiliary power circuit to eliminate single-point failure to ensure reliability
Built-in manual bypass ensures continuous power to the load even if the UPS is under maintenance
Greater Flexibility
A wide choice of configurations, such as N+X redundancy, and hot stand-by
Adjustable charging current and battery voltage meet different battery configuration requirements
Flexible battery configuration optimizes battery investment
Superior Serviceability and Management
Swappable interior architecture and front access servicing enables quick and easy maintenance*
* Applied for models HPH-60/80/100/120K
Multi-connectivity interface supports remote UPS monitoring and management*
Specifications
Model
HPH-20K, HPH-30K, HPH-40K,
HPH-60K, HPH-80K, HPH-100K, HPH-120K
HPH-20K-BN/B, HPH-30K-BN/B, HPH-40K-BN/B
Power Rating
HPH-20K : 20 kVA/kW
HPH-30K : 30 kVA/kW
HPH-40K : 40 kVA/kW
HPH-60K : 60 kVA/kW
HPH-80K : 80 kVA/kW
HPH-100K : 100 kVA/kW
HPH-120K : 120 kVA/kW
Input
Nominal Voltage : 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
Voltage Range
HPH-20~40K : 300~477 Vac (full load), 228~300 Vac (70%~100% load)
HPH-60~120K : 332~477 Vac (full load), 228~332 Vac (63%~100% load)
Frequency : 40~70Hz
Power Factor : > 0.99 (full load)
Current Harmonic Distortion : < 3%
Output
Voltage : 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
Voltage Regulation : ± 1 %
Voltage Harmonic Distortion
HPH-20~40K : < 1.5% (linear load)
HPH-60~120K : <2% (linear load)
Overload Capability
≤105 %: continuous
106% ~ ≤125%: 10 minutes
126% ~ ≤150%: 1 minute
>150%: 1 second
Output Power Factor : 1
Frequency : 50/60Hz +/- 0.05Hz
Battery
Battery Voltage : 240Vdc
Type : Support SMF/VRLA/Tubular/Ni-Cd
Quantity
HPH-20~40K : 32-50 pcs
HPH-60~120K : 32-46 pcs***
Charge Current (Max.) Built-in
HPH-20K : 5A
HPH-30/40K : 9A
HPH-60K : 10A
HPH-80K : 15A
HPH-100/120K : 20A
Typical Backup Time**
HPH-20K-BN/B : 15 min
HPH-30K-BN/B : 10 min
HPH-40K-BN/B : 9.5 min
Communication Interfaces
SMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1, REPO Port x 1, Charger Detection Port x 1, Input Dry Contact x 2, Output Dry Contact x 6, USB Port x 1*
Conformance
Safety : CE, RCM
UPS Classification According to IEC 62040-3 : VFI-SS-111
Other Features
Parallel Redundancy : Up to 4 units
Emergency Power Off : Yes (local and remote)
Maintenance Bypass Switch : Yes
Keywords
120 kW
10 min
15 min
USB Port
kW Input
low iTHD
100% load
full load
MINI Slot
hot stand
REPO Port
32-46 pcs
models HPH
SMART Slot
fan design
RS232 Port
228~332 Vac
332~477 Vac
228~300 Vac
300~477 Vac
linear load
240Vdc Type
Three Phase
wide choice
failure rate
battery life
energy costs
Parallel Port
manual bypass
32-50 pcs HPH
Up to 4 units
N+X redundancy
ideal solution
Other Features
Charge Current
Output Voltage
The Ultron HPH
significant TCO
cost efficiency
Nominal Voltage
battery voltage
Emergency Power
15A HPH-100/120K
easy maintenance
Watch-dog design
continuous power
DELTA HPH Series
Fully rated power
70Hz Power Factor
Input Dry Contact
Conformance Safety
Ownership) savings
Voltage Regulation
battery investment
Output Dry Contact
small data centers
Parallel Redundancy
Overload Capability
Greater Flexibility
Output Power Factor
Typical Backup Time
single-point failure
96% AC-AC efficiency
DSP based technology
electronic components
remote UPS monitoring
increased availability
RCM UPS Classification
class power protection
Charger Detection Port
Low harmonic pollution
front access servicing
Superior Serviceability
Class Power Performance
maximum available power
power factor correction
high input power factor
Leading AC-AC efficiency
Wide input voltage range
Maintenance Bypass Switch
HPH-40K-BN/B Power Rating
upstream investment costs
Redundant auxiliary power
three level IGBT topology
superior power performance
maximum power availability
Voltage Harmonic Distortion
Current Harmonic Distortion
Adjustable charging current
mission critical operations
Multi-connectivity interface
Specifications Model HPH-20K
unbeatable energy efficiency
dual auxiliary power circuit
advanced digital PFC control
harsh electrical environments
Flexible battery configuration
Swappable interior architecture
9.5 min Communication Interfaces
true online double-conversion UPS
other mission critical applications
Support SMF/VRLA/Tubular/Ni-Cd Quantity HPH
different battery configuration requirements