AMARON BRUTE HI LIFE TRACTION BATTERIES

Amaron Sleek front terminal batteries are designed with True Front terminals and delivers optimal performance in high temperature conditions and deep cycle usage conditions. Manufactured in world's largest integrated MVRLA plant having state of the art manufacturing facilities, this range is designed to offer superior performance in all power backup requirements.Design Float life of 12+ years in accordance with Eurobat Classification of Long Life battery

Send Message
product image
HPL Lithium-Ion Battery Energy Storage System

The HPL Lithium-Ion Battery Energy Storage System is a type of energy storage technology that uses lithium-ion batteries to store and manage electrical energy. These systems are typically used to store excess energy generated from renewable sources like solar and wind or from the grid, and release it when needed to help stabilize energy supply and demand. Here’s a breakdown of the key components and features that are generally associated with Lithium-Ion Battery Energy Storage Systems (BESS), including those from HPL or similar manufacturers: Key Features: Lithium-Ion Technology: Lithium-ion batteries are favored for their high energy density, long cycle life, and efficient performance. They are commonly used in applications like electric vehicles, grid storage, and consumer electronics. Energy Storage: These systems store electrical energy in lithium-ion battery packs and release it during periods of high demand, or when renewable energy production is low (e.g., on cloudy days for solar energy systems). Efficiency: Lithium-ion batteries typically offer high efficiency in terms of energy conversion, with round-trip efficiencies often exceeding 90%. This means that most of the stored energy is usable when discharged. Modular Design: HPL and other manufacturers often design their battery systems with modularity in mind. This means that the system can be scaled to fit a variety of needs, from residential to commercial and industrial applications. Grid Integration: These energy storage systems are commonly integrated with the electrical grid. They can help balance grid frequency and voltage, provide backup power during outages, and support the integration of renewable energy sources by smoothing fluctuations in supply. Battery Management System (BMS): The BMS ensures the safety, performance, and longevity of the battery by monitoring the state of charge (SOC), temperature, and other critical parameters. It can also prevent overcharging, over-discharging, and overheating. Applications: Residential Use: Homeowners can use these systems to store solar energy for use during the night or power outages. Commercial & Industrial Use: Businesses can use these systems to reduce demand charges or to provide backup power. Grid-Scale: Large energy storage systems can be used to stabilize the grid and facilitate the integration of renewable energy at a larger scale. Advantages: Sustainability: By storing renewable energy, these systems contribute to reducing carbon footprints and dependence on fossil fuels. Flexibility: They can be used in a wide range of applications, including residential, commercial, and large-scale energy storage. Cost Savings: Especially in commercial applications, they can help reduce energy costs by managing peak demand and reducing reliance on expensive grid power during peak periods.

Send Message
product image
Amaron Quanta 12V 130Ah Battery In Bhiwadi

The Amaron Quanta 12V 130Ah batteries are lead-acid batteries typically used for solar power storage, backup power systems, and other applications that require reliable energy storage. Here's a detailed overview of this battery: Key Features of Amaron Quanta 12V 130Ah Battery: Battery Type: Lead-Acid: This is a type of flooded or sealed (VRLA) lead-acid battery, suitable for deep cycle applications. 12V System: Designed for systems that operate on a 12V DC supply, often used in small-scale solar energy systems, inverters, and backup power setups. Capacity: 130Ah (Ampere-hour): This indicates the battery’s storage capacity. It means the battery can deliver 130 amps for 1 hour or 1 amp for 130 hours at a nominal voltage of 12V. For example, if the system uses 1A of current, the battery will last for around 130 hours before needing a recharge. Applications: Solar Power Systems: To store energy generated by solar panels. UPS (Uninterruptible Power Supply): Provides backup during power outages. Off-Grid Systems: Stores energy for homes or businesses in remote areas. Electric Vehicles and RVs: Sometimes used for backup and auxiliary power. Charging and Discharging: Charging: The battery can be charged through solar panels, inverters, or a regular charger. It is recommended to avoid deep discharges to extend the battery life. Discharging: It should not be discharged fully for longevity. Typically, a depth of discharge (DoD) of 50% to 70% is ideal for long-term use. Battery Life: Cycle Life: Typically, a lead-acid battery like the Amaron Quanta 12V 130Ah can last around 3-5 years, depending on usage and maintenance. Proper charging and maintenance (like keeping the terminals clean and ensuring adequate ventilation) can improve the lifespan of the battery. Advantages: Reliable and Cost-Effective: Lead-acid batteries are typically less expensive than other types of batteries, like lithium-ion. Widely Available: Amaron is a well-known brand, and their batteries are widely available and easy to replace. Maintenance: Flooded Lead-Acid: If it’s a flooded type, you may need to periodically check the water levels and top up with distilled water. VRLA (Valve-Regulated Lead-Acid): If it's a sealed type, it requires less maintenance as it’s sealed and does not need water refills. Specifications: Voltage: 12V Capacity: 130Ah Weight: Around 40-45 kg (approx.), depending on the specific model and construction type. Dimensions: Varies by model, but typically it is about 410mm (L) x 175mm (W) x 240mm (H). Conclusion: The Amaron Quanta 12V 130Ah battery is a good choice for off-grid solar systems, backup power applications, or any system requiring long-lasting energy storage. It offers a solid balance of performance, cost-effectiveness, and reliability. Proper care and maintenance will ensure it provides reliable service for years to come.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
9PX Lithium-ion UPS

The Eaton 9PX Lithium-ion UPS is designed for mission-critical applications, offering an extended battery life of 8 to 10 years. It features power ratings from 1 to 6 kVA, advanced ABM technology for battery longevity, and flexible configurations for both rack and tower setups. Key Specifications: Power Ratings: 1 kVA to 6 kVA Battery Type: Lithium-ion with 8-10 years life expectancy Form Factor: Rackmount and tower options Connectivity: Multiple external battery module options Warranty: 5 years on electronics and internal batteries Key Features: ABM Technology: Extends battery service life by up to 50% Remote Management: Capable of remote monitoring and management Compact Design: Space-saving design suitable for various environments Output: Pure sine wave output for sensitive equipment Performance and Reliability: Run Time: Varies based on load; designed for high availability Noise Level: Operates quietly, suitable for office environments

Send Message
product image
20kva ups

The Vertiv ITA 20kVA UPS is a robust power protection solution designed for mission-critical applications. Here are the key details: Vertiv ITA 20kVA UPS Overview Type: True online, double conversion, three-phase UPS. **Power Rating - Capacity: 20 kVA / 20 kW. Input Voltage: Configurable for 380/400/415 VAC. Frequency: Operates at 50/60 Hz. Design Features Form Factor: Compact rack-tower design for installation flexibility. Dimensions: Designed to fit in standard server racks or as a standalone unit. Weight: Approximately 200 kg (varies by configuration). Performance Specifications Efficiency: High efficiency with a unity power factor, ensuring maximum power delivery. Output: Provides both three-phase and single-phase output options. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Battery and Backup Battery Type: Typically uses lead-acid batteries, with options for lithium-ion for longer life and reduced maintenance. Backup Time: Varies based on load; designed to provide extended backup for critical systems. Monitoring and Management Display: LCD screen for real-time monitoring of UPS status, battery health, and load levels. Communication: Equipped with SNMP/Web card for remote monitoring and management capabilities. Management Software: Compatible with Vertiv\'s monitoring solutions for enhanced management. Applications Ideal for small computer rooms, network equipment, and data centers requiring reliable power protection. Suitable for industries such as healthcare, finance, and telecommunications where uptime is critical. Conclusion The Vertiv ITA 20kVA UPS is a highly efficient and reliable power protection solution, designed to meet the demands of critical applications with its advanced features and robust performance.

Send Message
product image
Amaron Quanta 12V 42ah Smf Batteries With Vertiv 2Kva Ups

The Amaron 12V 42Ah battery is commonly used in various uninterruptible power supply (UPS) systems, including those from Vertiv. When paired with a Vertiv 2 kVA UPS, it provides reliable backup power for critical applications. Below are the details regarding both the Amaron battery and its application in a Vertiv 2 kVA UPS system. Amaron 12V 42Ah Battery Type: Sealed Lead Acid (SLA) battery, specifically designed for deep cycle applications. Voltage: Nominal Voltage: 12 Volts. Capacity: Ah Rating: 42 Ampere-hours (Ah), which indicates the battery's capacity to deliver a specific current for a certain period. Dimensions: Size: Typically around 9.5 x 5.5 x 8.5 inches (L x W x H), but this can vary by manufacturer. Weight: Approximately 30-35 lbs (13-16 kg), depending on the specific model and manufacturer. Construction: Maintenance-Free: The sealed design prevents leakage and reduces maintenance requirements. Durability: Designed to withstand vibrations and shocks, making it suitable for various environments. Discharge Characteristics: Cycle Life: Can typically provide around 300-500 cycles at 100% discharge, depending on usage and maintenance. Operating Temperature: Generally operates efficiently within a temperature range of -15°C to 50°C (5°F to 122°F). Vertiv 2 kVA UPS Power Rating: Capacity: 2 kVA (2000 VA) / typically around 1.6 kW output, depending on the power factor. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring maximum protection for connected equipment. Input Specifications: Input Voltage: Typically accepts 110-240 VAC. Input Frequency: 50/60 Hz (auto-sensing). Output Specifications: Output Voltage: Configurable, typically 220/230/240 VAC. Output Connections: Multiple IEC or NEMA outlets for connecting devices. Battery Compatibility: The 2 kVA UPS can be paired with multiple 12V batteries (like the Amaron 12V 42Ah) in series or parallel configurations to achieve the desired runtime and capacity. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 for management and monitoring. Some models may have SNMP options. Physical Dimensions: Size: Generally around 3U to 5U in height, depending on the specific model. Weight: Approximately 50-70 lbs (22-32 kg) for the UPS alone, excluding batteries. Applications The combination of the Amaron 12V 42Ah battery with a Vertiv 2 kVA UPS is ideal for protecting critical IT equipment, networking devices, and servers in small to medium-sized data centers, server rooms, and telecommunications environments. Summary The Amaron 12V 42Ah battery is a reliable choice for use in a Vertiv 2 kVA UPS, providing the necessary backup power to maintain operations during outages. The UPS offers advanced features like online double-conversion technology and real-time monitoring, ensuring that sensitive equipment remains protected. For the most accurate and specific details, including installation, configuration, and warranty information, it's advisable to refer to the official documentation from Vertiv and Amaron or consult with their respective representatives.

Send Message
product image
Amaron Batteries Vertiv Ups In Baghanki Manesar

Using Amaron batteries with Vertiv UPS (Uninterruptible Power Supply) systems can provide a reliable backup power solution for various applications. Here’s a comprehensive overview: Vertiv UPS Overview Purpose: Designed to ensure continuous power supply during outages, protect against power surges, and stabilize voltage fluctuations. Types: Includes models for home use, data centers, industrial applications, and more. Key Features: High Efficiency: Advanced technologies for reduced energy consumption. Modular Design: Some models allow for scalable capacity as needed. User-Friendly Interface: LCD displays show battery status, load information, and alerts. Amaron Batteries Overview Type: Generally lead-acid batteries (deep-cycle) or, in some cases, lithium-ion. Voltage Options: Commonly available in 12V, suitable for most Vertiv UPS systems. Capacity: Ranges from 46Ah to over 200Ah, depending on your backup needs. Compatibility Voltage Matching: Ensure the Amaron battery voltage (e.g., 12V) matches the UPS requirements. Capacity Selection: Choose a battery capacity that meets the total load and desired backup duration. Calculate based on the wattage of connected devices. Installation Connecting the Battery: Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal. Connect the negative (-) terminal to the UPS negative terminal. Ensure Secure Connections: Make sure all connections are tight to avoid arcing or power loss. Performance Benefits Extended Runtime: Higher capacity Amaron batteries can provide longer backup durations during outages. Deep Cycle Capability: Designed to handle regular deep discharges, making them ideal for UPS applications. Low Maintenance: Many Amaron batteries require minimal maintenance, offering convenience for users. Maintenance Regular Inspections: Periodically check for corrosion on terminals and ensure all connections are secure. Battery Monitoring: Use a multimeter or UPS diagnostics to check battery health and voltage levels. Signs of Replacement: Be aware of performance degradation, such as reduced backup time or inability to hold charge. Safety Precautions Adequate Ventilation: Ensure good airflow around the UPS and battery to prevent gas accumulation, especially with lead-acid batteries. Proper Charging Practices: Follow guidelines to prevent overcharging, which can damage the battery. Conclusion Pairing Amaron batteries with Vertiv UPS systems can create a robust and reliable backup power solution. This combination helps ensure your devices remain operational during power outages and protects against voltage irregularities. Always consult the user manuals for both the UPS and batteries to ensure proper installation and compatibility, maximizing the performance of your power backup system.

Send Message
product image
Vertiv 2 kVA UPS In Patel Nagar Gurgaon

The Vertiv 2 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protection for various electronic devices, making it suitable for both IT and industrial applications. Here are the key details: Specifications: Power Rating: 2 kVA (approximately 1600 watts, depending on the power factor) Input Voltage: Typically operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave for compatibility with sensitive equipment. Battery Type: Generally sealed lead-acid or lithium-ion (varies by model). Features: Automatic Voltage Regulation (AVR): Protects against voltage fluctuations by stabilizing the output. LCD Display: Provides real-time data on battery status, load level, and input/output voltage. Multiple Outlets: Usually includes several output sockets for connecting multiple devices. Communication Ports: USB, RS-232, or network management options for monitoring and management. Hot-Swappable Batteries: Enables battery replacement without shutting down the UPS. Applications: IT Infrastructure: Ideal for servers, networking equipment, and critical computing systems. Small to Medium Enterprises: Suitable for point-of-sale systems, office equipment, and telecommunications. Industrial Use: Can be used for powering essential equipment in various industrial settings. Advantages: Reliable Backup Power: Ensures continuity during power outages, preventing data loss and downtime. Compact and Efficient: Designed for easy installation and energy efficiency. Scalability: Can be used in conjunction with other UPS systems for larger setups. Considerations: Battery Runtime: Evaluate the expected runtime based on the connected load; larger loads will reduce runtime. Maintenance: Regular maintenance checks and timely battery replacements are essential for performance. Always consult the specific model’s user manual for detailed specifications, features, and installation instructions tailored to your needs.