AMARON QUANTA 12V 200Ah BATTERY

The Amaron 12V 200Ah battery, specifically the Quanta series, is a sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery designed for various applications, including UPS systems. It has a nominal voltage of 12V, a rated capacity of 200Ah, and dimensions of approximately 556mm x 186mm x 263mm, weighing around 62kg. Key Features Sealed Maintenance-Free (SMF) Technology: Eliminates the need for regular maintenance, ensuring hassle-free operation. Durability: Engineered for exceptional durability and longevity, making it suitable for diverse operational environments. Advanced Safety Features: Includes flame-retardant components and enhanced thermal management for increased safety. Compact Design: Facilitates easy installation, ideal for both standalone and rack-mounted configurations. High Discharge Performance: Lower internal resistance allows for superior high-discharge performance. Fast Charging: Instacharge technology provides excellent charge acceptance for quick recharging. Corrosion-Resistant Alloy: Unique heavy-duty alloy for positive grids enhances cyclic life, especially in tropical environments. PPCP Containers: Low permeability design prevents water loss, ensuring optimal performance. Specifications Brand: Amaron Quanta Model: 12AL200 Voltage: 12V Capacity: 200Ah Weight: Approximately 62kg Dimensions: 556mm (L) x 186mm (W) x 263mm (H) Battery Type: SMF (Sealed Maintenance Free) Technology: AGM (Absorbed Glass Mat) Applications UPS Systems: Ideal for uninterruptible power supply systems. Telecommunications: Suitable for backup power in telecom applications. Renewable Energy Systems: Can be used in solar power setups. Industrial Applications: Provides reliable power for various industrial needs. Warranty: Typically comes with a manufacturer's warranty, ensuring reliability and support. User Reviews Generally positive feedback, highlighting the battery's performance, reliability, and value for money. Users have reported satisfaction with its longevity and maintenance-free operation.

Send Message
product image
5SC UPS

The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports. Key Specifications: Power Ratings: 500 VA to 1500 VA Output: Pure sine wave Connectivity: USB, serial, and relay Battery Type: Sealed lead-acid, maintenance-free Dimensions: Varies by model Weight: Approximately 34 lbs to 50 lbs depending on the model For more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices. Key Features: Power Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA Output Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems Battery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50% Connectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux) Display: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode Design: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR) Performance and Reliability: Run Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads Warranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment Noise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit User Experience: Setup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface Software: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead Customer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation

Send Message
product image
12V 150Ah

The Amaron Quanta 12V 150Ah battery is a sealed maintenance-free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for various applications, including UPS systems and renewable energy storage. Here are the key details: Voltage: 12V Capacity: 150Ah Type: Sealed Maintenance-Free (SMF) VRLA Dimensions: Typically larger than smaller batteries, suitable for various applications (exact dimensions may vary by model) Weight: Heavier due to higher capacity (exact weight may vary) Warranty: Generally comes with a warranty period of around 24 months Applications: Ideal for UPS systems, inverters, solar energy storage, and other backup power solutions Features: Low self-discharge rate High cycle life Excellent performance in high-temperature conditions Vibration-resistant design Fully sealed to prevent leakage Customer Reviews: Average rating based on user feedback is positive, highlighting good value for money and satisfactory service. Contact Information: For inquiries, you can reach out via: Email:info@universalpower.co.in Call or WhatsApp: 8744823336 For more specific details, you may want to check the product listings on the respective websites or contact the suppliers directly.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
Vertiv 500 kva Ups

The Vertiv 500 kVA UPS (Uninterruptible Power Supply) is a high-capacity power protection solution designed for industrial applications, data centers, and critical infrastructure. Here’s a detailed overview of its features, specifications, benefits, and maintenance practices. Vertiv 500 kVA UPS Overview Key Features High Power Capacity: Provides 500 kVA of power, suitable for large-scale applications requiring substantial backup power. Topologies: Online Double-Conversion: This design ensures continuous, clean, and stable power by converting incoming AC to DC and then back to AC, offering maximum protection against power disturbances. High Efficiency: Typically achieves efficiencies of 95% or higher, reducing energy consumption and operational costs. Scalability: Supports parallel operation with multiple units for increased redundancy and power capacity as your needs grow. Advanced Battery Management: Features for optimizing battery performance, including temperature monitoring, state of charge, and predictive diagnostics. User-Friendly Interface: LCD or LED displays provide real-time monitoring of power status, battery health, and load levels. Network Management Capabilities: Integration with network management systems for remote monitoring and control, often through SNMP or web interfaces. Vibration and Shock Resistance: Designed to withstand industrial environments, making it reliable for mission-critical applications. Multiple Input/Output Options: Flexible configurations to match various voltage and phase requirements. Specifications (Typical) Input Voltage: 380/400/415 V (Three-phase) Output Voltage: 380/400/415 V (Three-phase) Output Frequency: 50/60 Hz (auto-sensing) Efficiency: Up to 98% in eco mode. Dimensions: Varies by model; typically designed for rack or floor mounting. Weight: Can exceed 1000 kg, depending on configuration and battery type. Battery Types: Can support various battery technologies, including lead-acid and lithium-ion. Benefits Reliability: Ensures uninterrupted power supply and protects critical loads from power disturbances. Cost Savings: High efficiency leads to lower energy costs, while predictive maintenance helps avoid expensive downtimes. Enhanced Performance: Maintains stable output voltage and frequency, protecting sensitive equipment. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime and reliability. Robust Design: Built to withstand harsh industrial conditions, ensuring longevity and performance. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts as needed. Battery Management: Monitor battery health, perform load tests, and replace batteries according to manufacturer guidelines. Documentation: Keep detailed records of maintenance, inspections, and performance metrics. Emergency Support: Engage professional services for emergency repairs and technical support when needed. Conclusion The Vertiv 500 kVA UPS is a robust solution designed for high-demand environments, ensuring reliable power protection for critical applications. With its advanced features and capabilities, it is ideal for data centers, industrial applications, and other mission-critical settings. Proper maintenance and proactive management can further enhance its performance and longevity. If you have specific questions or need additional details, feel free to ask!

Send Message
product image
Ups And Batteries

Vertiv offers a range of UPS solutions tailored for different applications, including data centers, telecommunications, industrial environments, and more. Their systems are known for reliability, efficiency, and advanced features. Key Features of Vertiv UPS Systems Power Capacity: Various models available, ranging from small single-phase UPS (1 kVA) to large three-phase systems (up to 500 kVA or more). Topologies: Online Double-Conversion: Provides the highest level of protection by converting incoming AC to DC and then back to AC, ensuring clean and stable power. Line-Interactive: Adjusts voltage fluctuations without switching to battery, suitable for less critical applications. High Efficiency: Many models boast high efficiency ratings, often exceeding 95%, which reduces operational costs. Battery Options: Lead-Acid Batteries: Common and cost-effective, but heavier and shorter lifespan. Lithium-Ion Batteries: Increasingly available, offering longer life, lower weight, and higher efficiency. Modular Design: Some models are modular, allowing for scalable configurations that can grow with your power needs. Advanced Battery Management: Features to enhance battery lifespan, including temperature monitoring, equalization charging, and smart diagnostics. User-Friendly Interface: Intuitive LCD or LED displays for easy monitoring of power status, battery health, and load levels. Network Management: Options for SNMP or web-based monitoring allow for remote management of UPS performance. Parallel Operation: Supports parallel operation for redundancy and increased capacity. Battery Systems Types of Batteries Used: Lead-Acid Batteries: Sealed Lead Acid (SLA): Maintenance-free and widely used; available in various configurations. Valve-Regulated Lead Acid (VRLA): Designed to be more durable and safe. Lithium-Ion Batteries: Offer longer cycle life, lower weight, and better energy density. Can provide up to 10 years of life or more, depending on usage. Typical Specifications (Examples) Input Voltage: 380/400/415 V (three-phase). Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Efficiency: Up to 98% in eco-mode for certain models. Form Factor: Tower or rack-mounted options, based on the model. Benefits of Vertiv UPS with Batteries Reliability: Ensures uninterrupted power supply, crucial for mission-critical operations. Scalability: Easily expand capacity by adding additional UPS units or modules. Cost-Effectiveness: High efficiency leads to lower energy costs; predictive maintenance can help avoid costly downtime. Enhanced Protection: Maintains stable power output, protecting sensitive equipment from surges and outages. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime. Maintenance and Support Annual Maintenance Contracts (AMC): Regular inspections, preventive maintenance, and support services ensure optimal performance. Battery Replacement Services: Timely replacement of batteries as per usage and manufacturer recommendations is critical for maintaining efficiency and reliability. Conclusion Vertiv UPS systems paired with appropriate battery solutions provide a robust and efficient power protection strategy for various applications. With their focus on reliability, efficiency, and advanced features, Vertiv UPS systems are well-suited for mission-critical environments. If you need more specific information about particular models or configurations, feel free to ask!

Send Message
product image
Exide Bike Battery In Bhiwadi

Exide bike batteries are designed for high performance and durability in two-wheelers. Here are key details: Type: VRLA (Valve Regulated Lead Acid) and conventional flooded batteries, suitable for different bike models. Features: Maintenance-free, spill-proof, vibration-resistant, and designed for quick starting power. Applications: Used in motorcycles, scooters, and other two-wheelers for reliable starting and backup power. Durability: High resistance to extreme temperatures and rough road conditions. Maintenance: Low maintenance with easy water level checks (for conventional types). Exide is a trusted brand for two-wheeler batteries, known for its long-lasting performance and reliability.

Send Message
product image
Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.