10 kW solar system installed at M3M

Universal Power team has installed a 10 kW solar system 18 panel at M3M Key Details of the Installation: Solar System Size: 10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions. Number of Panels: 18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\'s total capacity by the number of panels. 10 kW / 18 panels = approximately 555 watts per panel. This indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems. Location – M3M: M3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint. Energy Production: The energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions. In an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity. Purpose: The solar power system could be installed for various reasons: To reduce energy bills by using clean solar energy. To support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient. To provide backup power or support the grid, especially in commercial or industrial settings. Benefits of a 10 kW Solar System: Reduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time. Environmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels. Increased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs. Government Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.

Send Message
product image
solar panel

A solar panel is a device that converts sunlight into electricity using photovoltaic (PV) cells. Here's a quick summary: Types: Monocrystalline: High efficiency, long lifespan, more expensive. Polycrystalline: Lower efficiency, cheaper. Thin-film: Lightweight, flexible, lower efficiency, cheaper. How It Works: Sunlight hits the PV cells, generating electrical current (DC), which is converted into AC power by an inverter for household use. Benefits: Renewable energy source. Reduces electricity bills. Environmentally friendly (low carbon footprint). Low maintenance. Can be paired with battery storage for energy independence. Lifespan: Most panels last 25-30 years with minimal maintenance. Efficiency: Varies from 10% to 22%, with monocrystalline being the most efficient. Installation: Requires site assessment, permits, and professional installation.

Send Message
product image
5 kW solar system installed at nooh school

Universal Power team has installed a 5 kW solar system at nooh school Key Details of the 5 kW Solar System Installation at Nooh School: Solar Power Generation: A 5 kW system typically generates around 20-25 kWh per day depending on sunlight hours and weather conditions. Annual Energy Production: The system could produce around 7, 300 to 9, 125 kWh annually, which can cover a significant portion of the school\'s energy needs. System Components: Solar Panels: Typically, 15-20 panels with a capacity of around 250W-330W each. Inverter: A 5 kW inverter is used to convert the DC power produced by the panels into AC power. Mounting Structure: The solar panels are mounted on the roof or ground, depending on the school\'s infrastructure. Grid Connection: The system is likely connected to the grid, allowing excess energy to be fed back into the grid via net metering, helping reduce electricity costs for the school. Benefits for Nooh School: Cost Savings: The school will benefit from reduced electricity bills by offsetting its grid power usage with solar energy. Sustainability: The system will contribute to a reduction in carbon emissions, helping the school be more environmentally responsible. Educational Opportunity: The solar installation can serve as a live example for students, providing them with a practical demonstration of renewable energy technology. Maintenance: The system requires minimal maintenance, with occasional cleaning of the panels to ensure optimal performance. Panel Lifespan: Solar panels generally last around 25-30 years, with a slight decline in efficiency over time. Inverter Lifespan: Inverters typically last around 10-15 years before needing replacement. Conclusion: The 5 kW solar system installed by Universal Power Team at Nooh School will provide long-term benefits, including reduced electricity costs, environmental sustainability, and educational opportunities for students to learn about solar energy. If more detailed information is needed, contacting Universal Power Team or the school would provide the specifics of the installation.

Send Message
product image
10 kW solar system installed at Parashuram Eye Hospital

10 kW solar Universal Power team has installed a 10 kW solar system at Parashuram Eye Hospital. Key Details of the 10 kW Solar System Installation: Solar Power Generation: A 10 kW system typically generates about 40-50 kWh per day, depending on the location and weather conditions. This translates to 14,600 to 18,250 kWh annually, which will help the hospital meet a significant portion of its energy needs. System Components: Solar Panels: Around 25-30 panels, each with a capacity of 330W-400W. Inverter: A 10 kW inverter is used to convert the DC electricity from the panels into AC electricity for hospital use. Mounting System: Panels are mounted on the roof or ground depending on the hospital's infrastructure. Grid Connection: The system is connected to the grid, allowing the hospital to export excess energy to the grid through net metering. Benefits for Parashuram Eye Hospital: Cost Reduction: The solar system will reduce the hospital's dependence on grid electricity, leading to lower monthly electricity bills. Sustainability: The hospital will be contributing to environmental sustainability by utilizing renewable energy, which helps reduce its carbon footprint. Energy Independence: The system ensures a reliable power source, especially during peak hours or grid outages. Maintenance: Solar panels require minimal maintenance, with periodic cleaning to ensure maximum efficiency. Lifespan: Solar panels typically last 25-30 years, and the inverter may need replacement after 10-15 years. Conclusion: The installation of a 10 kW on-grid solar power system at Parashuram Eye Hospital by Universal Power Team will provide long-term benefits in terms of cost savings, energy independence, and environmental impact. It’s an excellent step towards sustainable energy usage for the hospital. If you need more specific details about this installation, it would be best to contact Universal Power Team or the hospital directly.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
10KVA UPS

The Vertiv™ Liebert® GXE 6000-10000VA UPS is part of the Liebert GXE Series, which provides line-interactive power protection with advanced features, making it an ideal solution for small and medium-sized businesses, IT infrastructure, and critical equipment in need of reliable power backup. The Liebert GXE UPS offers features like Automatic Voltage Regulation (AVR), extended battery support, efficient performance, and compact design. Here are all the key details and specifications for the Vertiv™ Liebert® GXE 6000-10000VA UPS: Vertiv Liebert GXE 10000VA UPS (10kVA) Power Rating: 10kVA / 10000VA Output Power: 6000W to 8000W Input Voltage: 170V - 280V Output Voltage: 230V ± 10% Waveform: Simulated Sinewave (or Pure Sinewave for specific models) Battery Type: Sealed Lead-Acid (SLA) / VRLA Battery Capacity: Typically 12V, 18Ah or 24Ah (with external battery options) Charging Time: 4-6 hours for a full recharge Backup Time: 10-40 minutes depending on load and battery configuration Form Factor: Tower or Rackmount Interfaces: USB/Serial, SNMP (optional) Additional Features: AVR, Smart Battery Management, LCD Display, Overload Protection, Alarms, External Battery Support Key Features: Topology: Line-Interactive – This topology offers good protection and ensures that your equipment receives stable power during fluctuations, such as brownouts or overvoltages, without using battery power unnecessarily. Power Rating: 6kVA to 10kVA (6000VA to 10000VA) – Suitable for medium to large-sized IT infrastructure, servers, networking equipment, and other critical applications that need consistent and reliable power. Output Power: 6kVA (6000VA) models typically provide 3600W - 4800W of output power. 10kVA (10000VA) models provide 6000W - 8000W of output power, depending on the specific model and configuration. Input Voltage Range: 170V - 280V (wide input voltage range) – Provides protection from both high and low voltage fluctuations. Output Voltage: 230V ± 10% – Standard output voltage suitable for most business and IT applications. Waveform Type: Simulated Sinewave – In line-interactive mode, the output waveform is simulated sinewave. However, the UPS is designed to handle sensitive loads well. Automatic Voltage Regulation (AVR): The Liebert GXE UPS comes with AVR that corrects voltage fluctuations without switching to battery power, reducing battery wear and extending the overall life of the system. Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries – Commonly used for UPS systems due to their reliability and low maintenance. Battery Capacity: 12V batteries, with 18Ah, 24Ah, or higher capacity depending on the model and configuration. Extended Battery Support: The UPS can be connected to additional battery packs for longer backup runtimes if needed. Charging Time: Typically, the battery recharge time is around 4-6 hours for a full charge from a discharged state. Backup Time (Runtime): Backup time varies depending on load. For example: At 50% load, the runtime could range from 30 minutes to 1 hour. At full load, the backup time may range from 10-20 minutes, depending on the model and load. External Battery Packs can extend runtime significantly for longer power outages. Form Factor: Tower or Rackmount options are available, making the Liebert GXE adaptable for different environments, such as server rooms or small data centers. Rackmount models are designed for 19-inch racks and are ideal for installations in IT environments. Cooling: Fan-assisted cooling for efficient thermal management. Interfaces & Monitoring: USB/Serial Communication Ports for connection with monitoring and management software. SNMP Slot: Provides optional SNMP (Simple Network Management Protocol) support for remote monitoring and management. LCD Display: Many models include an LCD screen that shows real-time UPS status, load, battery condition, input/output voltage, and other important information. Smart Battery Management: Ensures that the batteries are efficiently charged and maintained, extending the life of the battery bank. Advanced battery diagnostics can help predict failures and improve overall UPS reliability. Overload Protection: Provides protection against equipment overload and ensures that the system shuts down or enters bypass mode in the event of a fault condition. Audible Alarms: Alarms provide real-time alerts for conditions like battery low, overload, fault conditions, and input/output abnormalities. Green Features: Energy-Efficient: Offers high energy efficiency to reduce operational costs. ECO Mode: In certain conditions, the system can operate in ECO mode to provide further energy savings, reducing electricity consumption.

Send Message
product image
1 KVA UPS

VERTIV 1kVA UPS SB MODEL & LB MODEL The Vertiv 1kVA UPS comes in various models, with common models being the SB (Standby) and LB (Line-Interactive) series. These are uninterruptible power supplies designed to provide backup power and protection for critical equipment like servers, networking devices, and other sensitive electronic systems. Let’s break down the general features and details of both SB and LB models in the 1kVA range. 1. Vertiv 1kVA SB (Standby) Series UPS The SB Series is typically a basic Standby UPS designed to offer essential protection for home office and small business applications. The main purpose of the SB UPS is to provide basic surge protection and power backup during outages. Key Features: Topology: Standby Power Rating: 1kVA / 1000VA Output Power: 600W - 800W (varies by specific model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (for typical models) Waveform Type: Simulated Sinewave (basic sinewave approximation) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries Battery Capacity: 12V, 7Ah or 9Ah (depending on model) Charging Time: Typically 4-8 hours to fully charge the battery Run Time: Provides backup power for 5-15 minutes depending on the load Interfaces: Often includes USB or serial ports for monitoring (depending on model) Form Factor: Tower type, compact design Additional Features: Surge protection Automatic voltage regulation (AVR) Overload and short-circuit protection Low battery and overload indicators Fan-assisted cooling for efficient operation Ideal Use Case: Small offices, home offices, and workstations Network routers, modems, and smaller networking equipment Low power devices and equipment 2. Vertiv 1kVA LB (Line-Interactive) Series UPS The LB Series is a more advanced line-interactive UPS system, designed for more demanding applications that require better efficiency and more consistent power quality. Key Features: Topology: Line-Interactive Power Rating: 1kVA / 1000VA Output Power: 800W - 900W (varies by specific model) Input Voltage: 140V - 300V (wider input range compared to SB) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave or Pure Sinewave (depending on the model and configuration) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 7Ah or 9Ah Charging Time: Around 4-6 hours for full charge Run Time: Offers longer backup time, depending on load (usually 10-20 minutes for 50-75% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB/Serial ports for monitoring, sometimes includes software for automatic shutdown Additional Features: Automatic Voltage Regulation (AVR) for stabilizing voltage fluctuations Enhanced battery management to extend battery life Cold start capability (UPS can start without mains power) Overload protection LCD display for real-time status monitoring (on some models) Audible alarms for low battery, overload, and fault conditions Ideal Use Case: Small to medium-sized servers, workstations, and critical network equipment Sensitive medical equipment Point-of-sale (POS) systems Small business IT infrastructure

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
amc

To provide you with details about UPS (Uninterruptible Power Supply) and batteries, particularly in the context of AMC (Annual Maintenance Contract), here’s a comprehensive overview: UPS (Uninterruptible Power Supply) Purpose: A UPS provides backup power during outages and protects against power surges, ensuring that electronic equipment remains operational. Types of UPS: Offline/Standby UPS: Activates during power failure. Suitable for personal computers and basic electronic equipment. Line-Interactive UPS: Adjusts voltage fluctuations without switching to battery. Good for small to medium-sized businesses. Online UPS: Continuously provides power from the battery, even during normal operation. Ideal for critical applications requiring consistent power. Components: Batteries: Store energy to provide backup. Inverter: Converts DC from batteries to AC for equipment. Charger: Maintains battery charge. Control Circuit: Manages the UPS operations. Batteries Types Used in UPS: Lead-Acid Batteries: Common in UPS systems. Cost-effective, but heavier and have a shorter lifespan. Lithium-Ion Batteries: Increasingly popular due to longer life and lower weight. More expensive but offer better efficiency. Annual Maintenance Contract (AMC) Purpose of AMC: An AMC ensures regular maintenance, reducing the risk of system failures and prolonging the lifespan of the UPS and batteries. Key Components of AMC: Regular Inspections: Scheduled checks to assess the condition of UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts. Emergency Support: Availability of technical support in case of a failure. Replacement Services: Agreement on the replacement of batteries and components when necessary. Performance Monitoring: Tracking the UPS performance metrics to ensure efficiency. Choosing an AMC Provider Considerations: Reputation: Look for providers with good reviews and experience. Service Level Agreement (SLA): Ensure clear terms regarding response times and services offered. Expertise: Check for qualified technicians with experience in your specific UPS model. Cost: Compare costs while considering the level of service provided. Conclusion An AMC for your UPS system is crucial for maintaining reliability and performance, especially for critical operations. Regular maintenance helps prevent unexpected downtime and extends the life of both the UPS and its batteries. If you need specific recommendations or details about AMC providers in your area, let me know!