Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
3kva ups

The Vertiv Liebert GXT MT+ 3KVA UPS is an online double-conversion uninterruptible power supply designed for reliable power protection. It features a compact tower design, a wide input voltage range, and an intuitive LCD display for easy monitoring. The UPS offers high efficiency, with double conversion efficiency up to 90%, ensuring optimal performance in various conditions. Here are the key details: Key Features Double Conversion Technology: Provides continuous power conditioning and protection against power disturbances. Input Voltage Range: Wide input voltage range allows for operation in diverse environments. LCD Display: New graphical LCD display provides real-time UPS data, alarms, and aids in fault diagnostics. Efficiency: High efficiency of up to 90% at full load, contributing to lower energy costs. Compact Design: Space-saving tower design suitable for various installations. Extended Runtime Options: Available models with extended runtime capabilities for critical applications. Automatic Frequency Detection: Automatically detects and adjusts to the input frequency. Input Circuit Breaker: Protects the UPS and connected equipment from overloads. Active Power Factor Correction: Enhances the input power factor, reducing energy consumption. Specifications Power Rating: 3KVA / 3000W Output Voltage: 230V or 208V options available Form Factor: Tower Weight: Varies by model, typically around 20-30 kg Dimensions: Compact dimensions for easy placement in IT environments Applications Ideal for IT infrastructure, data centers, and critical equipment requiring uninterrupted power supply. Suitable for environments with stringent power quality requirements. Conclusion The Vertiv Liebert GXT MT+ 3KVA UPS is a robust solution for ensuring the health and availability of critical systems, providing reliable power protection and efficient operation in various settings.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
10KVA UPS

The Vertiv™ Liebert® GXE 6000-10000VA UPS is part of the Liebert GXE Series, which provides line-interactive power protection with advanced features, making it an ideal solution for small and medium-sized businesses, IT infrastructure, and critical equipment in need of reliable power backup. The Liebert GXE UPS offers features like Automatic Voltage Regulation (AVR), extended battery support, efficient performance, and compact design. Here are all the key details and specifications for the Vertiv™ Liebert® GXE 6000-10000VA UPS: Vertiv Liebert GXE 10000VA UPS (10kVA) Power Rating: 10kVA / 10000VA Output Power: 6000W to 8000W Input Voltage: 170V - 280V Output Voltage: 230V ± 10% Waveform: Simulated Sinewave (or Pure Sinewave for specific models) Battery Type: Sealed Lead-Acid (SLA) / VRLA Battery Capacity: Typically 12V, 18Ah or 24Ah (with external battery options) Charging Time: 4-6 hours for a full recharge Backup Time: 10-40 minutes depending on load and battery configuration Form Factor: Tower or Rackmount Interfaces: USB/Serial, SNMP (optional) Additional Features: AVR, Smart Battery Management, LCD Display, Overload Protection, Alarms, External Battery Support Key Features: Topology: Line-Interactive – This topology offers good protection and ensures that your equipment receives stable power during fluctuations, such as brownouts or overvoltages, without using battery power unnecessarily. Power Rating: 6kVA to 10kVA (6000VA to 10000VA) – Suitable for medium to large-sized IT infrastructure, servers, networking equipment, and other critical applications that need consistent and reliable power. Output Power: 6kVA (6000VA) models typically provide 3600W - 4800W of output power. 10kVA (10000VA) models provide 6000W - 8000W of output power, depending on the specific model and configuration. Input Voltage Range: 170V - 280V (wide input voltage range) – Provides protection from both high and low voltage fluctuations. Output Voltage: 230V ± 10% – Standard output voltage suitable for most business and IT applications. Waveform Type: Simulated Sinewave – In line-interactive mode, the output waveform is simulated sinewave. However, the UPS is designed to handle sensitive loads well. Automatic Voltage Regulation (AVR): The Liebert GXE UPS comes with AVR that corrects voltage fluctuations without switching to battery power, reducing battery wear and extending the overall life of the system. Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries – Commonly used for UPS systems due to their reliability and low maintenance. Battery Capacity: 12V batteries, with 18Ah, 24Ah, or higher capacity depending on the model and configuration. Extended Battery Support: The UPS can be connected to additional battery packs for longer backup runtimes if needed. Charging Time: Typically, the battery recharge time is around 4-6 hours for a full charge from a discharged state. Backup Time (Runtime): Backup time varies depending on load. For example: At 50% load, the runtime could range from 30 minutes to 1 hour. At full load, the backup time may range from 10-20 minutes, depending on the model and load. External Battery Packs can extend runtime significantly for longer power outages. Form Factor: Tower or Rackmount options are available, making the Liebert GXE adaptable for different environments, such as server rooms or small data centers. Rackmount models are designed for 19-inch racks and are ideal for installations in IT environments. Cooling: Fan-assisted cooling for efficient thermal management. Interfaces & Monitoring: USB/Serial Communication Ports for connection with monitoring and management software. SNMP Slot: Provides optional SNMP (Simple Network Management Protocol) support for remote monitoring and management. LCD Display: Many models include an LCD screen that shows real-time UPS status, load, battery condition, input/output voltage, and other important information. Smart Battery Management: Ensures that the batteries are efficiently charged and maintained, extending the life of the battery bank. Advanced battery diagnostics can help predict failures and improve overall UPS reliability. Overload Protection: Provides protection against equipment overload and ensures that the system shuts down or enters bypass mode in the event of a fault condition. Audible Alarms: Alarms provide real-time alerts for conditions like battery low, overload, fault conditions, and input/output abnormalities. Green Features: Energy-Efficient: Offers high energy efficiency to reduce operational costs. ECO Mode: In certain conditions, the system can operate in ECO mode to provide further energy savings, reducing electricity consumption.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
Batteries Repairing & AMC Services in Delhi

Overview: We provide specialized repairing and Annual Maintenance Contract (AMC) services for batteries ranging from 7Ah to 280Ah. Our services are designed to extend battery life, ensure optimal performance, and reduce unexpected costs. Services Offered: Battery Repair Services: Diagnostics and Testing: Comprehensive testing to identify issues such as capacity loss, internal resistance, and short circuits. Reconditioning: Techniques to restore battery capacity, including desulfation and electrolyte replenishment. Cell Replacement: Replacement of faulty cells to improve overall battery health. Sealing and Maintenance: Sealing and maintenance of battery terminals to prevent corrosion. Annual Maintenance Contracts (AMC): Regular Inspections: Scheduled inspections to monitor battery health and performance. Preventive Maintenance: Cleaning and servicing to prevent issues before they arise. 24/7 Support: Round-the-clock assistance for any battery-related emergencies. Customized Plans: AMC plans tailored to individual requirements and usage patterns. Battery Capacity Focus: Range: 7Ah to 280Ah Small Batteries (7Ah - 40Ah): Ideal for UPS systems, alarms, and backup power solutions. Medium Batteries (40Ah - 120Ah): Used in telecommunications, solar applications, and larger UPS systems. Large Batteries (120Ah - 280Ah): Suitable for industrial applications, large UPS systems, and energy storage solutions. Benefits of Our Services: Extended Battery Life: Regular maintenance and timely repairs can significantly increase battery lifespan. Cost-Effective Solutions: AMC services help prevent unexpected expenses due to battery failures. Expert Technicians: Skilled professionals with experience in handling various battery types and brands. Quick Turnaround: Efficient service delivery to minimize downtime. Safety Assurance: Adherence to safety standards during repairs and maintenance. Contact Information: For inquiries or to schedule a service, please contact us: Phone: 8744823336 Email: info@universalpower.co.in Address: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001

Send Message
product image
Vertiv 20Kva 3x1 Online Ups

The Vertiv Liebert GXT MT+ 20KVA 3X1 Online UPS System is a high-quality online UPS system designed to provide reliable and efficient power backup for various applications. Key Features True online double conversion with DSP control technology for high performance and reliability IGBT based rectifier New graphical LCD Display provides UPS data, alarms, and helps in faults diagnostics and trouble shooting Double conversion efficiency up to 90% Active input power factor corrections 0.99 0.9 output power factor Wide input voltage window (110-280 Vac) for Indian environmental conditions and for optimized battery performance Configurable output voltage Generator compatible with wide input frequency range (40Hz – 70Hz) 4 stage extendable charging design for optimized battery performance Adjustable battery charging current up to 12A according to battery capacity and rating 50/60 Hz automatic frequency converter mode Specifications Brand: Vertiv Model & Series: GXT MT+ 20KVA (3X1) Type: Online UPS Wave form: Pure sine wave Rating in VA: 20KVA Battery module: External Battery module Battery Type: SMF – VRLA Warranty: 24 Months Dimensions (DWH) in mm: 592250826 in mm Weight in Kgs (approx.): 45 Kgs Supplier Details The supplier of the Vertiv Liebert GXT MT+ 20KVA 3X1 Online UPS System is Universal Power System, a wholesale trader with a wide range of products, including APC Online UPS, Online UPS, Microtek UPS, Exide UPS Battery, Quanta Batteries, and more. They are located in Gurgaon, India.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.