Gurugram
+918076792323

'initial phase'

Items tagged with 'initial phase'

product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Vertiv Three Phase Online Ups

The Vertiv Online UPS systems offer a range of three-phase solutions designed for critical power applications. Here are some key models and their specifications: 1. Liebert EXS Power Rating: Up to 20 kVA Output Configuration: Configurable for three-phase (3/3) or single-phase (3/1) output Flexibility: On-site configuration allows adaptation to changing power needs Efficiency: High efficiency with double conversion technology Applications: Suitable for data centers and critical IT infrastructure 2. Liebert ITA2 Power Rating: Up to 10 kVA Design: Available in rackmount or tower configurations Reliability: Economical and efficient three-phase power for critical loads Features: High power factor and compact design 3. Liebert NX Power Rating: 40-200 kVA Scalability: Allows growth from 40 to 60 to 80 kVA, and from 80 to 100 to 120 kVA Parallel Operation: Can be paralleled for additional capacity or redundancy Efficiency: Designed for high efficiency and reliability 4. Vertiv Trinergy Power Rating: 1500-2500 kW Modular Design: High-capacity modular UPS for large applications Reliability: Maximized reliability with advanced features for critical systems 5. Liebert NXL Power Rating: Up to 800 kW Input Voltage: 480VAC, three-phase, three-wire Load Voltage: 480VAC, three-phase, three-wire in and out or four-wire in Applications: Ideal for large data centers and mission-critical environments General Features Across Models Double Conversion Technology: Ensures continuous power conditioning and protection against power disturbances High Efficiency: Designed to minimize energy costs while maximizing performance Advanced Monitoring: Many models include LCD displays for real-time monitoring and diagnostics Flexible Configurations: Options for tower or rackmount installations to suit various environments Conclusion Vertiv\'s three-phase UPS systems provide robust and reliable power protection for critical applications, ensuring the availability and integrity of essential systems in data centers and other mission-critical environments.

Send Message
product image
UPS

Vertiv Liebert PSA - 1000VA Mini Tower UPS PSA1000MT3-230U Specifications and Details The Vertiv Liebert PSA PSA1000MT3-230U is a line-interactive uninterruptible power supply (UPS) designed to provide reliable power protection for small office computers and electronic equipment. Below are the detailed specifications and features of this UPS model. Key Specifications Model: Vertiv Liebert PSA PSA1000MT3-230U Capacity: VA: 1000 VA Watts: 600 Watts Form Factor: Mini Tower Phase: Single Phase (1:1) Battery Type: Lead Acid Run Time: Typical: 5 minutes (varies with load) Warranty: 2 years Physical Dimensions Height: 234 mm Width: 147 mm Depth: 360 mm Weight: 9.5 kg Features User -Friendly LED Display: Provides easy operation and monitoring of UPS status. Socket Configuration: Multiple battery-backed and surge-protected sockets to accommodate different types of loads. Includes a mix of battery-backed and surge-only sockets. USB Communication: Comes with USB communications/shutdown software and cable for plug-and-play use. User -Replaceable Batteries: Designed for easy battery replacement to maximize the initial investment. Data Line Protection: Protects data lines to ensure the safety of connected devices. Environmental Compliance: Fully RoHS compliant, ensuring it meets environmental standards. Additional Information Input Voltage: Typically operates at 230 VAC. Output Waveform: Simulated sine wave. Runtime Performance: Provides 5 or more minutes of battery backup depending on the load level. Conclusion The Vertiv Liebert PSA PSA1000MT3-230U is an efficient and cost-effective solution for power protection in small office environments. Its combination of features, including user-friendly interfaces, multiple socket options, and easy maintenance, makes it a reliable choice for safeguarding electronic equipment against power interruptions.

Send Message
product image
UPS

Emerson offers a range of three-phase industrial UPS systems designed to provide reliable power protection for critical applications. Here are some key details typically associated with Emerson's three-phase UPS solutions: Key Features Power Capacity: Models often range from 10 kVA to several hundred kVA, catering to different industrial requirements. Topology: Many models utilize an online double-conversion topology, which ensures continuous power supply and zero transfer time during outages. Efficiency: High-efficiency ratings (up to 96% or more) help reduce energy costs and heat generation. Modular Design: Many systems allow for modular configurations, enabling easy scalability and redundancy. Smart Battery Management: Advanced battery management systems extend battery life and enhance performance. User Interface: LCD screens or touchscreen interfaces for real-time monitoring, diagnostics, and control. Communication Protocols: Various options for remote monitoring and integration, including SNMP, Modbus, and other industry-standard protocols. Input/Output Configuration: Flexible I/O options for different electrical environments, often with customizable settings. Applications Data centers Industrial automation systems Telecommunications Manufacturing facilities Critical power applications in healthcare Considerations Installation: Requires professional installation to ensure compliance with local electrical codes and optimal performance. Maintenance: Regular maintenance checks are necessary for reliability; consider a service contract for ongoing support. Load Assessment: Properly assess total load requirements to select the appropriate UPS capacity. Environmental Conditions: Ensure the UPS is suitable for the operating environment (temperature, humidity, etc.). Popular Models Emerson has various models within its UPS lineup, including: Liebert APM: Modular UPS systems known for scalability and high efficiency. Liebert EXL S1: High-density UPS for critical loads, offering excellent performance and efficiency. Conclusion When considering an Emerson three-phase industrial UPS, it's essential to evaluate specific needs, including power requirements, space constraints, and operational conditions. For the most accurate and detailed information, including specifications and installation requirements, consult Emerson's official documentation or contact a local representative. If you have specific models or features in mind, let me know!

Send Message
product image
Vertiv 3 Kva Single Phase Ups

The Vertiv 3 kVA single-phase UPS is designed to provide reliable power protection for small to medium-sized applications, such as servers, telecommunications equipment, and sensitive electronic devices. Here’s a comprehensive overview of its key features, specifications, and applications: Key Features Reliable Power Protection: Offers stable and clean power to protect critical equipment from surges, sags, and outages. Compact Design: Ideal for environments with limited space, easily fitting into small racks or on desktops. High Efficiency: Many models boast efficiency ratings of over 90%, reducing energy costs. User-Friendly Interface: Often includes an LCD display for easy monitoring of battery status, load levels, and UPS health. Extended Battery Life: Intelligent battery management systems help prolong battery lifespan and optimize performance. Multiple Connectivity Options: Typically includes USB and RS-232 ports for monitoring and management. Specifications (Typical Vertiv 3 kVA Model) Power Rating: 3 kVA / 2.4 kW Input Voltage: 230V single-phase Output Voltage: 230V single-phase Input Frequency: 50/60 Hz (auto-sensing) Efficiency: Generally exceeds 90% in online mode Battery Type: Typically uses valve-regulated lead-acid (VRLA) or lithium-ion batteries Form Factor: Tower configuration for easy placement Communication Interfaces: USB, RS-232, with optional SNMP for network management Applications Small Business Environments: Provides backup power for computers, POS systems, and other critical devices. Home Offices: Protects home office equipment from power disruptions. Telecommunications: Ensures the reliability of communication devices and networks. Retail Applications: Supports electronic point-of-sale systems and other sensitive electronics. Conclusion The Vertiv 3 kVA single-phase UPS is designed for reliability and efficiency, making it an excellent choice for various small to medium-sized applications. For specific models and detailed technical specifications, it's advisable to refer to the Vertiv website or contact a local distributor. If you have specific questions about a particular model or need more details, feel free to ask!

Send Message
product image
Battery

Amaron batteries are well-known for their performance and reliability in various applications, including automotive, UPS systems, and renewable energy setups. Here’s a comprehensive overview of charging Amaron batteries, covering methods, parameters, and best practices. Charging Amaron Batteries 1. Charging Methods: Constant Current (CC) Charging: The charger supplies a constant current until the battery reaches a predefined voltage. Commonly used for lead-acid batteries, ensuring a safe and efficient charge. Constant Voltage (CV) Charging: After reaching the target voltage, the charger maintains that voltage while the current decreases. This method is suitable for maintaining battery charge without overcharging. Smart Chargers: These chargers automatically adjust voltage and current based on the battery's state. They often include features like temperature compensation and multi-stage charging. 2. Charging Parameters: Voltage: For lead-acid Amaron batteries, the charging voltage typically ranges from 2.25V to 2.40V per cell. For a 12V battery (6 cells), this translates to about 13.5V to 14.4V. Current: The charging current should be set to 10-30% of the battery's capacity (C-rate). For example, a 100Ah battery should be charged at 10A to 30A. Temperature Compensation: Adjust the charging voltage based on the ambient temperature to avoid damage. Generally, for every degree Celsius above 25°C, reduce the charging voltage by 0.005V per cell. 3. Charging Stages: Bulk Charge: The initial phase where maximum current is applied to quickly charge the battery. This stage continues until the battery reaches approximately 70-80% of its capacity. Absorption Charge: The charger maintains a constant voltage, allowing the current to taper off as the battery approaches full charge. This phase ensures the battery reaches full capacity without overcharging. Float Charge: A lower voltage is maintained to keep the battery fully charged without overcharging. This is essential for maintaining the battery in a ready state for immediate use. Best Practices for Charging Amaron Batteries: Use the Right Charger: Always use a charger specifically designed for the type of battery you are charging (lead-acid, AGM, etc.). Avoid Deep Discharge: Regularly charge the battery to prevent deep discharges, which can shorten battery life. Monitor Temperature: Ensure the charging environment is within the recommended temperature range (typically 15°C to 25°C). Regular Maintenance: Periodically check the battery's state of charge and electrolyte levels (if applicable). Clean terminals and connections to ensure efficient charging. Follow Manufacturer Guidelines: Always refer to the specific charging instructions provided by Amaron for the particular battery model. Conclusion Proper charging of Amaron batteries is vital for maximizing their lifespan and performance. By following the recommended charging methods, parameters, and best practices, users can ensure that their batteries operate efficiently and reliably. If you have specific models in mind or need further details, feel free to ask!

Send Message
product image
Vertiv PowerBank 600 kVA Online UPS

Vertiv PowerBank 600 kVA Online UPS The Vertiv PowerBank 600 kVA Online UPS is designed for critical power applications, particularly in data centers and industrial environments. Here’s a comprehensive overview of its specifications, features, benefits, and considerations: Overview The Vertiv PowerBank 600 kVA UPS provides robust, uninterrupted power supply with advanced features for high availability, power quality, and energy efficiency. Key Specifications Power Rating: 600 kVA Input Voltage: Typically 400/415V (three-phase) Output Voltage: 400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion Efficiency: Up to 95% in normal operation and can reach 98% in eco mode Total Harmonic Distortion (THD): Typically <5% at full load Battery and Runtime Battery Type: Usually utilizes VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Configuration: Configurable based on requirements, with options for extended runtime Charging Time: Typically 4-8 hours for a full charge, depending on the battery type Runtime: Customizable based on load; options available for longer runtimes (requires additional battery packs) Features Advanced Monitoring: LCD display for real-time monitoring of status, input/output voltage, load percentage, battery status, and alarms. Redundancy: N+1 configuration for enhanced reliability and availability. Scalability: Capable of parallel operation with multiple units for increased capacity and redundancy. Smart Communication: SNMP, USB, and RS232 interfaces for remote management and monitoring. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Hot-Swap Batteries: Some configurations allow for battery replacement without turning off the UPS. Physical Characteristics Dimensions: Varies by model; typically around 120-150 cm in width and depth. Weight: Approximately 600-800 kg, depending on the configuration and battery type. Cooling: Generally air-cooled; ensure proper ventilation in the installation area. Benefits Power Quality: Provides clean, stable, and regulated power to sensitive equipment. High Availability: Designed for critical loads requiring uninterrupted power supply. Energy Efficiency: High-efficiency modes help reduce operational costs. User-Friendly: Intuitive interface and comprehensive management software facilitate easy operation. Considerations Installation: Professional installation is recommended to optimize configuration and ensure compliance with electrical standards. Maintenance: Regular inspections and battery maintenance are crucial for ensuring reliability and longevity. Environmental Conditions: Requires proper ventilation and should be installed in a climate-controlled environment to avoid overheating. Cost: Initial investment can be substantial; consider the total cost of ownership, including maintenance and energy savings. Applications Data Centers Telecommunications Infrastructure Industrial Power Applications Medical Facilities Financial Institutions Conclusion The Vertiv PowerBank 600 kVA UPS is a powerful and reliable solution for ensuring continuous power supply and protecting critical infrastructure.

Send Message
product image
Vertiv 40Kva Online Ups In udhyog vihar Gurgaon

The Vertiv 40 kVA UPS is designed to provide robust power protection and management for critical infrastructure in data centers, IT rooms, and industrial applications. It ensures that sensitive equipment remains operational during power disturbances. Key Specifications Power Rating: 40 kVA Input Voltage: Typically 380/400/415V (three-phase) Output Voltage: 380/400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion or line-interactive Efficiency: Up to 96% in eco mode Total Harmonic Distortion (THD): <5% at full load Battery and Runtime Battery Type: Typically uses VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Capacity: Varies based on configuration; options for extended runtime Charging Time: Usually 4-8 hours for a full charge (depending on battery type) Runtime: Configurable based on load; options for longer runtimes available Features Redundancy: N+1 configuration allows for increased reliability. Scalability: Can be expanded with additional units for greater capacity or redundancy. Smart Monitoring: Advanced LCD display for real-time monitoring of UPS status, input/output voltage, load percentage, battery status, and alarms. Communication Options: SNMP, USB, RS232, and optional network management cards for remote management. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Physical Characteristics Dimensions: Varies by model; generally within 60-80 cm in width and depth Weight: Approximately 200-400 kg (depends on battery configuration) Cooling: Typically air-cooled; ensure adequate airflow in the installation environment. Benefits Power Quality: Provides clean and stable power to connected equipment. High Availability: Ensures uptime for critical loads. Flexibility: Suitable for a wide range of applications including data centers, telecommunications, and industrial systems. User-Friendly: Intuitive interface and management software for easy operation and monitoring. Considerations Installation: Professional installation recommended to ensure optimal configuration. Maintenance: Regular inspections and battery replacements are crucial for reliability. Environment: Needs proper ventilation; avoid humid or extreme temperature environments. Cost: Initial investment can be significant; consider total cost of ownership including maintenance and energy savings. Applications Data Centers IT Infrastructure Telecommunications Industrial Equipment Medical Equipment Conclusion The Vertiv 40 kVA UPS is a versatile and powerful solution for ensuring continuous power availability and protecting critical infrastructure.

Send Message
product image
Vertiv Three Phase Ups In Faridabad

Vertiv three phase UPS systems are designed to provide reliable and efficient power protection for critical applications. They are available in a range of capacities and configurations to suit different needs. Key Features: Three phase power protection High efficiency and reliability Scalable and flexible design Advanced monitoring and control capabilities Types of Vertiv Three Phase UPS: Liebert ITA2: A three phase UPS system designed for small to medium-sized data centers and other critical applications. Liebert EXS: A three phase UPS system designed for medium to large-sized data centers and other critical applications. Liebert EXM: A three phase UPS system designed for large data centers and other critical applications. Liebert EXL S1: A three phase UPS system designed for large data centers and other critical applications. Applications: Data centers Critical infrastructure Industrial applications Healthcare applications Technical Specifications: Capacity: 10-500 kVA Voltage: 208-480V Frequency: 50-60Hz Efficiency: Up to 96% Power factor: 0.9-1.0 Warranty: 2-5 year warranty depending on the model

Send Message

Still searching for
initial phase?