Battery

The Amaron Quanta 12V 7Ah is a sealed lead-acid (SLA) battery commonly used in applications such as backup power systems, uninterruptible power supplies (UPS), security systems, and various other low-power applications. Here\'s a breakdown of its details: Key Specifications: Nominal Voltage: 12 Volts (V) Capacity: 7 Ampere-hours (Ah) at a rate of 20 hours (i.e., the battery can provide 0.35A of current for 20 hours). This is typical for deep-cycle applications, providing reliable performance over an extended period. Battery Type: Sealed Lead-Acid (SLA): Maintenance-free design. Can be installed in any orientation, though upright is recommended for optimal performance. Suitable for both float and cyclic applications. Dimensions: Length: 151 mm (5.94 inches) Width: 65 mm (2.56 inches) Height: 95 mm (3.74 inches) Weight: Approx. 2.3 kg (5.07 lbs) Terminal Type: F1 Faston connectors (0.187” wide), which are commonly used for quick connections. Operating Temperature: Discharge: -15°C to +50°C (5°F to 122°F) Charge: 0°C to +40°C (32°F to 104°F) Float Life: Typically 3-5 years in float (backup power) applications. Self-Discharge: SLA batteries typically have a low self-discharge rate of about 3-5% per month at 25°C, meaning they retain their charge relatively well when not in use for extended periods. Charge Voltage: Standard Charging Voltage: 13.5 to 13.8V (constant voltage charging) Maximum Charging Voltage: 14.4V Recommended Float Charging Voltage: 13.5V Cycle Life: Typically offers about 200-300 cycles at 100% discharge. The cycle life increases with lower depth of discharge (DoD). Applications: UPS Systems: To provide backup power for computers, networking equipment, and other devices. Solar Power Systems: As a small energy storage option in off-grid or backup solar systems. Alarm Systems: For providing power in case of a mains failure. Electric Vehicles & Mobility Scooters: In some cases for small EVs or battery-powered mobility solutions. Power Tools & Other Low Power Systems: To provide compact, reliable energy for tools and other devices. Safety & Maintenance: Maintenance-Free: No need to add water or maintain the electrolyte levels, as the battery is sealed. Overcharge Protection: Built-in mechanisms to prevent overcharging that could lead to damage or overheating. Overcurrent Protection: Built-in to prevent damage due to short circuits or excessive current. Warranty: Typically 1-2 years depending on the brand and country of purchase. Storage & Handling: Storage Temperature: Store in a cool, dry place, ideally between 15°C and 25°C. Do not store in a fully discharged state, as this can significantly reduce the lifespan of the battery. Regular Maintenance: If not in use for extended periods, check the battery voltage periodically and recharge it if necessary. The Amaron Quanta 12V 7Ah battery is designed for reliability and versatility, suitable for a variety of applications that require backup power or a small energy storage solution.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
solar panel

A solar panel is a device that converts sunlight into electricity using photovoltaic (PV) cells. Here's a quick summary: Types: Monocrystalline: High efficiency, long lifespan, more expensive. Polycrystalline: Lower efficiency, cheaper. Thin-film: Lightweight, flexible, lower efficiency, cheaper. How It Works: Sunlight hits the PV cells, generating electrical current (DC), which is converted into AC power by an inverter for household use. Benefits: Renewable energy source. Reduces electricity bills. Environmentally friendly (low carbon footprint). Low maintenance. Can be paired with battery storage for energy independence. Lifespan: Most panels last 25-30 years with minimal maintenance. Efficiency: Varies from 10% to 22%, with monocrystalline being the most efficient. Installation: Requires site assessment, permits, and professional installation.

Send Message
product image
Amaron Quanta 12V 18Ah Battery

The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features: 1. General Overview Brand: Amaron Quanta Battery Type: Sealed Lead-Acid (SLA) Battery Voltage: 12 Volts (V) Capacity: 18 Ampere-Hours (Ah) 2. Key Features Longer Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD). Maintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water). Vibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems. Wide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates. 3. Technical Specifications Voltage: 12V (Nominal) Capacity: 18Ah (Ampere-Hours) Dimensions: Length: 181 mm Width: 77 mm Height: 167 mm Weight: Around 5.2 to 5.5 kg (varies slightly based on exact model) Charge Voltage: 14.4V to 15.0V (during charging) Discharge Voltage: Typically 10.5V to 11.0V for complete discharge Self-discharge: Less than 3% per month at 25°C 4. Applications UPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics. Inverters: It can also be used in small-scale inverters to provide backup power to homes or offices. Telecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment. Solar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours. 5. Battery Design Features Valve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure. Deep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge. Absorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof. 6. Charge/Discharge Characteristics Charging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V. Discharge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan. 7. Advantages Longer Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use. Reliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments. Environmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills. 8. Maintenance Maintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended. Charging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan. 9. Warranty Amaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms. 10. Compatibility Compatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required. Charging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries. Conclusion The Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.

Send Message
product image
Amaron Quanta 12V 200Ah battery

The Amaron Quanta 12V 200Ah battery is a sealed maintenance-free (SMF) VRLA battery designed for high performance. It features a nominal voltage of 12 volts, a rated capacity of 200 ampere-hours, and dimensions of approximately 541 x 232 x 208 mm, weighing around 62 kg. Specifications Brand: Amaron Quanta Model: 12AL200 Battery Type: Sealed Maintenance Free (SMF) Voltage: 12V Capacity: 200Ah Dimensions: 556 x 186 x 263 mm Weight: 62 kg (± 5%) Key Features AGM Technology: Utilizes Absorbed Glass Mat technology for low maintenance and high reliability. Spill-Proof Design: Can be installed in any position without risk of leakage. High Discharge Performance: Lower internal resistance for superior performance during high discharge rates. Fast Charging: Instacharge technology allows for excellent charge acceptance. Durability: Designed to withstand tropical environments and heavy usage. Safety Features: Includes a one-way self-resealing safety vent and flame-retardant components. Applications

Send Message
product image
10 kW solar system installed at M3M

Universal Power team has installed a 10 kW solar system 18 panel at M3M Key Details of the Installation: Solar System Size: 10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions. Number of Panels: 18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\'s total capacity by the number of panels. 10 kW / 18 panels = approximately 555 watts per panel. This indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems. Location – M3M: M3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint. Energy Production: The energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions. In an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity. Purpose: The solar power system could be installed for various reasons: To reduce energy bills by using clean solar energy. To support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient. To provide backup power or support the grid, especially in commercial or industrial settings. Benefits of a 10 kW Solar System: Reduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time. Environmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels. Increased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs. Government Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.

Send Message
product image
Amaron Quanta 12V 130Ah Battery In Bhiwadi

The Amaron Quanta 12V 130Ah batteries are lead-acid batteries typically used for solar power storage, backup power systems, and other applications that require reliable energy storage. Here's a detailed overview of this battery: Key Features of Amaron Quanta 12V 130Ah Battery: Battery Type: Lead-Acid: This is a type of flooded or sealed (VRLA) lead-acid battery, suitable for deep cycle applications. 12V System: Designed for systems that operate on a 12V DC supply, often used in small-scale solar energy systems, inverters, and backup power setups. Capacity: 130Ah (Ampere-hour): This indicates the battery’s storage capacity. It means the battery can deliver 130 amps for 1 hour or 1 amp for 130 hours at a nominal voltage of 12V. For example, if the system uses 1A of current, the battery will last for around 130 hours before needing a recharge. Applications: Solar Power Systems: To store energy generated by solar panels. UPS (Uninterruptible Power Supply): Provides backup during power outages. Off-Grid Systems: Stores energy for homes or businesses in remote areas. Electric Vehicles and RVs: Sometimes used for backup and auxiliary power. Charging and Discharging: Charging: The battery can be charged through solar panels, inverters, or a regular charger. It is recommended to avoid deep discharges to extend the battery life. Discharging: It should not be discharged fully for longevity. Typically, a depth of discharge (DoD) of 50% to 70% is ideal for long-term use. Battery Life: Cycle Life: Typically, a lead-acid battery like the Amaron Quanta 12V 130Ah can last around 3-5 years, depending on usage and maintenance. Proper charging and maintenance (like keeping the terminals clean and ensuring adequate ventilation) can improve the lifespan of the battery. Advantages: Reliable and Cost-Effective: Lead-acid batteries are typically less expensive than other types of batteries, like lithium-ion. Widely Available: Amaron is a well-known brand, and their batteries are widely available and easy to replace. Maintenance: Flooded Lead-Acid: If it’s a flooded type, you may need to periodically check the water levels and top up with distilled water. VRLA (Valve-Regulated Lead-Acid): If it's a sealed type, it requires less maintenance as it’s sealed and does not need water refills. Specifications: Voltage: 12V Capacity: 130Ah Weight: Around 40-45 kg (approx.), depending on the specific model and construction type. Dimensions: Varies by model, but typically it is about 410mm (L) x 175mm (W) x 240mm (H). Conclusion: The Amaron Quanta 12V 130Ah battery is a good choice for off-grid solar systems, backup power applications, or any system requiring long-lasting energy storage. It offers a solid balance of performance, cost-effectiveness, and reliability. Proper care and maintenance will ensure it provides reliable service for years to come.

Send Message
product image
10 kW solar system installed at Parashuram Eye Hospital

10 kW solar Universal Power team has installed a 10 kW solar system at Parashuram Eye Hospital. Key Details of the 10 kW Solar System Installation: Solar Power Generation: A 10 kW system typically generates about 40-50 kWh per day, depending on the location and weather conditions. This translates to 14,600 to 18,250 kWh annually, which will help the hospital meet a significant portion of its energy needs. System Components: Solar Panels: Around 25-30 panels, each with a capacity of 330W-400W. Inverter: A 10 kW inverter is used to convert the DC electricity from the panels into AC electricity for hospital use. Mounting System: Panels are mounted on the roof or ground depending on the hospital's infrastructure. Grid Connection: The system is connected to the grid, allowing the hospital to export excess energy to the grid through net metering. Benefits for Parashuram Eye Hospital: Cost Reduction: The solar system will reduce the hospital's dependence on grid electricity, leading to lower monthly electricity bills. Sustainability: The hospital will be contributing to environmental sustainability by utilizing renewable energy, which helps reduce its carbon footprint. Energy Independence: The system ensures a reliable power source, especially during peak hours or grid outages. Maintenance: Solar panels require minimal maintenance, with periodic cleaning to ensure maximum efficiency. Lifespan: Solar panels typically last 25-30 years, and the inverter may need replacement after 10-15 years. Conclusion: The installation of a 10 kW on-grid solar power system at Parashuram Eye Hospital by Universal Power Team will provide long-term benefits in terms of cost savings, energy independence, and environmental impact. It’s an excellent step towards sustainable energy usage for the hospital. If you need more specific details about this installation, it would be best to contact Universal Power Team or the hospital directly.

Send Message
product image
VERTIV ITA UPS

The Vertiv Liebert ITA 5kVA Online UPS is designed for small computer rooms and network equipment, offering reliable power protection. Key features include a compact design, high power factor, scalable battery runtimes, and options for rackmount or tower configurations. For detailed specifications, you can refer to the datasheets available online. ### Key Specifications Model: Vertiv Liebert ITA 5kVA Type: Online UPS Power Rating: 5 kVA Input Voltage Range: Wide input voltage range, ensuring immunity to grid interference Output Voltage: Typically 230V (single phase) Efficiency: High efficiency, contributing to lower operational costs Key Features Double Conversion Technology: Provides clean and consistent power, protecting sensitive equipment from power disturbances. Programmable Output: Features programmable output outlets with cascade protection for critical devices during heavy loads. Integrated Monitoring: Comes with an integrated Ethernet port for remote monitoring via HTTP protocol. User -Friendly Interface: Gravity sense LCD display for easy monitoring and management. Robust Design: Built with a cutting-edge channelized airflow design for optimal cooling and performance. Applications Data Centers: Ideal for protecting servers and networking equipment. Telecommunications: Suitable for telecom applications requiring uninterrupted power. Healthcare: Ensures reliable power for critical medical equipment. Conclusion The Vertiv Liebert ITA 5kVA Online UPS is a robust solution for various applications requiring reliable power protection. Its advanced features and high efficiency make it a suitable choice for businesses looking to safeguard their critical equipment against power interruptions. Always consult with suppliers for the latest pricing and availability.