Gurugram
+918076792323

'many systems'

Items tagged with 'many systems'

product image
Vertiv 5kVA UPS

The Vertiv 5kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power for critical equipment, protecting them from power outages, surges, and other electrical disturbances. Vertiv is known for providing high-quality power management solutions, and a 5kVA UPS typically serves small to medium-sized applications such as: Server rooms Small data centers Telecommunication equipment Networking devices Medical equipment Key Features of a Vertiv 5kVA UPS: Power Capacity: 5kVA (Kilovolt-Ampere) translates to 5000 Volt-Amperes. This is roughly equivalent to 4000 watts, but the exact power capacity depends on the power factor (typically around 0.8 for UPS systems). Battery Backup: Ensures that connected equipment continues to run during power outages. The runtime depends on the load being connected and the battery capacity. Surge Protection: Provides protection against voltage spikes and surges, which can damage sensitive equipment. Voltage Regulation: The UPS can regulate incoming voltage to ensure connected devices receive consistent, safe power even if the input voltage fluctuates. Compact Design: These units are usually compact and designed to fit into standard server racks or other equipment areas. Advanced Features: Some Vertiv 5kVA models come with monitoring and management capabilities via network cards, allowing you to check the status, set alarms, or configure settings remotely. Scalability: Many Vertiv UPS systems are modular and can be expanded with additional battery packs or additional units if needed. Maintenance Bypass: Ensures continuous operation and simplifies service and maintenance tasks.

Send Message
product image
Vertiv 60 kVA UPS

The Vertiv 60 kVA Online UPS is an uninterruptible power supply (UPS) designed to provide reliable and continuous power to critical equipment in case of power interruptions. Here are some key details and features typically associated with this kind of UPS: Key Features: Online UPS Technology: The Vertiv 60 kVA UPS uses online double-conversion technology, meaning it provides constant, clean, and stable power to connected equipment by continuously converting incoming AC power to DC and then back to AC. High Capacity: With a capacity of 60 kVA (kilo volt-amperes), this UPS is ideal for medium to large-sized businesses or industrial applications that require a significant amount of power protection, such as data centers, manufacturing equipment, or IT infrastructure. Energy Efficiency: These systems are typically designed to offer high efficiency, reducing operational costs while maintaining reliable performance. Some models offer "eco-mode" functionality to optimize efficiency during non-critical times. Battery Management: Vertiv UPS units generally feature advanced battery management technology that ensures longer battery life, more efficient charging, and optimal performance. The batteries are usually hot-swappable, allowing for maintenance without shutting down the system. Compact Design: Despite its high capacity, the Vertiv 60 kVA Online UPS is designed to have a relatively compact form factor, making it easier to integrate into limited spaces in data centers or industrial settings. Communication and Monitoring: Many Vertiv UPS systems come equipped with intelligent monitoring systems that allow users to track performance, status, and any faults. This can often be done remotely through a web interface or software. Bypass Capability: Some models offer an internal bypass, which allows the load to continue operating even during maintenance or if the UPS needs to be shut down for any reason. Typical Applications: Data Centers: Ensuring that critical server equipment continues running during power interruptions. Industrial Automation: Protecting machinery and control systems from voltage sags or outages. Healthcare: Protecting medical equipment that is sensitive to power fluctuations. Telecommunications: Ensuring consistent power supply to communication infrastructure. Advantages: Continuous Power Protection: Ideal for environments where power outages can cause data loss, downtime, or even equipment damage. Scalability: Can be paired with additional units or battery banks for higher power requirements. Reliability: The Vertiv brand is well-regarded in the power protection industry for producing durable and dependable UPS systems.

Send Message
product image
Vertiv 10kVA UPS

A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers. Vertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances. Here are some key features you might find in a Vertiv 10kVA UPS: Power Capacity: 10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment. Efficiency: Many Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs. Battery Type: Typically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions. Form Factor: These systems may come in both rack-mounted or tower configurations, depending on space requirements. Scalability: Some Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity. Monitoring and Control: Advanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software. Surge Protection and Isolation: Protects your sensitive equipment from power surges, voltage spikes, and electrical noise. Maintenance Bypass: Many UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices. Vertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.

Send Message
product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
5SC UPS

The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports. Key Specifications: Power Ratings: 500 VA to 1500 VA Output: Pure sine wave Connectivity: USB, serial, and relay Battery Type: Sealed lead-acid, maintenance-free Dimensions: Varies by model Weight: Approximately 34 lbs to 50 lbs depending on the model For more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices. Key Features: Power Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA Output Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems Battery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50% Connectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux) Display: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode Design: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR) Performance and Reliability: Run Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads Warranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment Noise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit User Experience: Setup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface Software: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead Customer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation

Send Message
product image
Vertiv Three Phase Online Ups

The Vertiv Online UPS systems offer a range of three-phase solutions designed for critical power applications. Here are some key models and their specifications: 1. Liebert EXS Power Rating: Up to 20 kVA Output Configuration: Configurable for three-phase (3/3) or single-phase (3/1) output Flexibility: On-site configuration allows adaptation to changing power needs Efficiency: High efficiency with double conversion technology Applications: Suitable for data centers and critical IT infrastructure 2. Liebert ITA2 Power Rating: Up to 10 kVA Design: Available in rackmount or tower configurations Reliability: Economical and efficient three-phase power for critical loads Features: High power factor and compact design 3. Liebert NX Power Rating: 40-200 kVA Scalability: Allows growth from 40 to 60 to 80 kVA, and from 80 to 100 to 120 kVA Parallel Operation: Can be paralleled for additional capacity or redundancy Efficiency: Designed for high efficiency and reliability 4. Vertiv Trinergy Power Rating: 1500-2500 kW Modular Design: High-capacity modular UPS for large applications Reliability: Maximized reliability with advanced features for critical systems 5. Liebert NXL Power Rating: Up to 800 kW Input Voltage: 480VAC, three-phase, three-wire Load Voltage: 480VAC, three-phase, three-wire in and out or four-wire in Applications: Ideal for large data centers and mission-critical environments General Features Across Models Double Conversion Technology: Ensures continuous power conditioning and protection against power disturbances High Efficiency: Designed to minimize energy costs while maximizing performance Advanced Monitoring: Many models include LCD displays for real-time monitoring and diagnostics Flexible Configurations: Options for tower or rackmount installations to suit various environments Conclusion Vertiv\'s three-phase UPS systems provide robust and reliable power protection for critical applications, ensuring the availability and integrity of essential systems in data centers and other mission-critical environments.

Send Message
product image
UPS

Emerson offers a variety of Uninterruptible Power Supply (UPS) systems designed to provide reliable power protection for critical applications. Here’s an overview of their offerings: General Specifications: Types: Modular, transformerless, and line-interactive UPS systems. Input Voltage Range: Typically - Input Voltage Range: Typically 100V to 240V depending on the model. Output Voltage: Pure sine wave output for compatibility with sensitive electronic equipment. Form Factor: Available in both tower and rack-mount configurations. Key Models: 1. Emerson Liebert GXT5 Series: Ideal For: Data centers and critical IT applications. Features: High efficiency with online double-conversion technology. LCD display for real-time monitoring and diagnostics. Scalable runtime with external battery cabinets. Models: GXT5-1000RT120: 1000VA/900W GXT5-1500RT120: 1500VA/1350W GXT5-3000RT120: 3000VA/2700W 2. Emerson Liebert PSI5 Series: Features: Compact design suitable for small to medium-sized applications. USB and serial communication ports for monitoring. Built-in battery management for extended life. Models: PSI5-1000RT120: 1000VA/800W PSI5-1500RT120: 1500VA/1200W 3. Emerson Liebert APM Series: Features: Modular design for scalability and redundancy. High efficiency and low total cost of ownership. Advanced monitoring and management capabilities. Models: APM-10K: 10kVA modular UPS. APM-20K: 20kVA modular UPS. Key Features Across Models: High Efficiency: Many models offer efficiencies of 95% or higher, reducing energy costs. Advanced Monitoring: Options for remote monitoring and management through software solutions. Flexible Configuration: Supports various installation environments and requirements. Applications: Data Centers: Protects critical servers and networking equipment. Healthcare: Ensures reliable power for medical devices and systems. Industrial: Supports machinery and equipment during power interruptions. Advantages: Robust Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Scalability: Modular options allow for future expansion as power needs grow. Emerson UPS systems are designed to deliver reliable power protection and management solutions tailored to the needs of various industries, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message

Still searching for
many systems?