Gurugram
+918076792323

'other edge'

Items tagged with 'other edge'

product image
6 KVA UPS

The Vertiv 6kVA UPS models, including the Liebert GXT5 and GXT MTX+, feature specifications such as a power capacity of 6000 VA, double conversion efficiency, and a wide input voltage range. They are designed for critical power applications, ensuring reliable performance and advanced monitoring capabilities. Vertiv 6kVA UPS Overview Model Variants: The primary models include the Liebert GXT5 and GXT MTX+. Power Capacity: Each model provides a power capacity of 6000 VA (6kW), suitable for various critical applications. Technology: Utilizes online double conversion technology, ensuring continuous power conditioning and protection against power disturbances. Power Factor: Features a unity power factor (1.0), allowing for maximum efficiency and more connected loads. Design: Compact and versatile, these UPS units can be configured for both rack and tower installations. Monitoring: Equipped with built-in communication cards for remote monitoring, enabling users to manage and monitor UPS status effectively. Runtime Options: Offers scalable runtime options with external battery cabinets, providing extended backup during outages. Certification: ENERGY STAR 2.0 certified, indicating energy efficiency and reduced operational costs. Display: Intuitive full-color LCD display for easy monitoring and management of UPS functions. Warranty: Typically comes with a 3-year warranty, ensuring reliability and support. Applications Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply. Suitable for both centralized and edge computing environments, providing flexibility in deployment. Additional Features Software Integration: Compatible with Vertiv Power Insight software for consolidated monitoring of multiple UPS units. Protection Plans: Extended and accidental damage protection plans are available for added security. Shipping and Packaging: Usually packaged as a single unit, with shipping calculations available upon request.

Send Message
product image
5kva

The Vertiv Liebert GXT5 5kVA UPS is an online double-conversion uninterruptible power supply designed for critical infrastructure protection. It operates at 5kVA/5kW with user-selectable output voltages of 208V and 120V. This UPS features continuous power conditioning, ensuring that connected equipment is safeguarded against power disturbances and outages. Here are the key details: Key Features Power Rating: 5kVA / 5kW Input/Output Voltage: 208V in / 208V out (also supports 120V out) Power Factor: High power factor (0.9-1.0) allows for more connected loads, optimizing space and cost Design: Tower/rack mountable for flexible installation Remote Monitoring: Equipped with a built-in Vertiv RDU101 communications card for remote monitoring Software Support: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Runtime Options: Scalable runtime with external battery cabinets for extended backup during outages Certification: ENERGY STAR 2.0 certified for energy efficiency Display: Intuitive gravity-sensing full-color LCD display for easy status monitoring Additional Information Applications: Suitable for both centralized and edge locations, protecting critical equipment in various environments Warranty and Support: On-site service and advanced exchange service options available after remote diagnosis, ensuring quick resolution of issues Conclusion The Vertiv Liebert GXT5 5kVA UPS is a robust solution for ensuring continuous power supply and protection for critical systems, making it ideal for data centers, IT infrastructure, and other sensitive applications.

Send Message
product image
6 kva ups

The Vertiv 6 kVA UPS models, such as the Liebert GXT5 and Liebert GXT MTX+, offer robust power protection for critical equipment. Here are the key specifications and details: Vertiv Liebert GXT5 6 kVA/6 kW Model: Liebert GXT5 Capacity: 6 kVA / 6 kW Input Voltage: 208/120V Output Power Factor: 1.0 (Unity) Form Factor: Rack/Tower Dimensions: Depth: 25.6 inches Rack Height: 4U Weight: Approximately 125.60 lbs Backup/Run Time: Half Load: 9.50 minutes Full Load: 3.50 minutes Transfer Time: 0 ns (no break) Receptacle Type: Hardwired Bypass Switch: Automatic & Manual; Internal Emergency Power OFF: Yes Audible Noise: Less than 55 dBA at 1 meter Vertiv Liebert GXT MTX+ 6 kVA Model: Liebert GXT MTX+ Output Power Factor: 0.8 Input Voltage Range: 110 — 300 Vac Charging Design: 4 Stage Extendable Charging for optimized battery performance Adjustable Battery Charging Current: 1/2/4/6 Amps based on battery capacity Compact Design: Best-in-class online UPS system General Features Type: Online Double Conversion UPS Protection: Protects against outages and all types of power disturbances Applications: Suitable for centralized and edge locations, ideal for critical equipment These UPS systems are designed to ensure reliable power supply and protect sensitive electronic equipment from power disturbances, making them essential for data centers, telecommunications, and other critical applications.

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
Exide Bike Battery In Bhiwadi

Exide bike batteries are designed for high performance and durability in two-wheelers. Here are key details: Type: VRLA (Valve Regulated Lead Acid) and conventional flooded batteries, suitable for different bike models. Features: Maintenance-free, spill-proof, vibration-resistant, and designed for quick starting power. Applications: Used in motorcycles, scooters, and other two-wheelers for reliable starting and backup power. Durability: High resistance to extreme temperatures and rough road conditions. Maintenance: Low maintenance with easy water level checks (for conventional types). Exide is a trusted brand for two-wheeler batteries, known for its long-lasting performance and reliability.

Send Message
product image
Microtek inverter In Bawal

Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points: Types: Available in pure sine wave, square wave, and modified sine wave models to suit different needs. Applications: Used for home, office, and industrial backup power systems. Features: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems. Compatibility: Works well with various battery types, including lead-acid and lithium-ion. Durability: Built to withstand power fluctuations and extreme conditions. Microtek is known for its durable and cost-effective inverters, widely used across India and other regions.

Send Message

Still searching for
other edge?