Gurugram
+918076792323

'other power backup systems'

Items tagged with 'other power backup systems'

product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Microtek inverter In Bawal

Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points: Types: Available in pure sine wave, square wave, and modified sine wave models to suit different needs. Applications: Used for home, office, and industrial backup power systems. Features: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems. Compatibility: Works well with various battery types, including lead-acid and lithium-ion. Durability: Built to withstand power fluctuations and extreme conditions. Microtek is known for its durable and cost-effective inverters, widely used across India and other regions.

Send Message
product image
Amaron Tubular Battery In Faridabad

Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points: Design: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions. Applications: Commonly used in inverters, solar power systems, and other backup power solutions. Durability: Known for high resistance to corrosion and low maintenance requirements. Performance: Excellent charge retention and high power output, even in harsh conditions. Maintenance: Requires periodic checking of water levels and occasional equalization charging. Amaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Vertiv 5kVA UPS

The Vertiv 5kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power for critical equipment, protecting them from power outages, surges, and other electrical disturbances. Vertiv is known for providing high-quality power management solutions, and a 5kVA UPS typically serves small to medium-sized applications such as: Server rooms Small data centers Telecommunication equipment Networking devices Medical equipment Key Features of a Vertiv 5kVA UPS: Power Capacity: 5kVA (Kilovolt-Ampere) translates to 5000 Volt-Amperes. This is roughly equivalent to 4000 watts, but the exact power capacity depends on the power factor (typically around 0.8 for UPS systems). Battery Backup: Ensures that connected equipment continues to run during power outages. The runtime depends on the load being connected and the battery capacity. Surge Protection: Provides protection against voltage spikes and surges, which can damage sensitive equipment. Voltage Regulation: The UPS can regulate incoming voltage to ensure connected devices receive consistent, safe power even if the input voltage fluctuates. Compact Design: These units are usually compact and designed to fit into standard server racks or other equipment areas. Advanced Features: Some Vertiv 5kVA models come with monitoring and management capabilities via network cards, allowing you to check the status, set alarms, or configure settings remotely. Scalability: Many Vertiv UPS systems are modular and can be expanded with additional battery packs or additional units if needed. Maintenance Bypass: Ensures continuous operation and simplifies service and maintenance tasks.

Send Message
product image
HPL Lithium-Ion Battery Energy Storage System

The HPL Lithium-Ion Battery Energy Storage System is a type of energy storage technology that uses lithium-ion batteries to store and manage electrical energy. These systems are typically used to store excess energy generated from renewable sources like solar and wind or from the grid, and release it when needed to help stabilize energy supply and demand. Here’s a breakdown of the key components and features that are generally associated with Lithium-Ion Battery Energy Storage Systems (BESS), including those from HPL or similar manufacturers: Key Features: Lithium-Ion Technology: Lithium-ion batteries are favored for their high energy density, long cycle life, and efficient performance. They are commonly used in applications like electric vehicles, grid storage, and consumer electronics. Energy Storage: These systems store electrical energy in lithium-ion battery packs and release it during periods of high demand, or when renewable energy production is low (e.g., on cloudy days for solar energy systems). Efficiency: Lithium-ion batteries typically offer high efficiency in terms of energy conversion, with round-trip efficiencies often exceeding 90%. This means that most of the stored energy is usable when discharged. Modular Design: HPL and other manufacturers often design their battery systems with modularity in mind. This means that the system can be scaled to fit a variety of needs, from residential to commercial and industrial applications. Grid Integration: These energy storage systems are commonly integrated with the electrical grid. They can help balance grid frequency and voltage, provide backup power during outages, and support the integration of renewable energy sources by smoothing fluctuations in supply. Battery Management System (BMS): The BMS ensures the safety, performance, and longevity of the battery by monitoring the state of charge (SOC), temperature, and other critical parameters. It can also prevent overcharging, over-discharging, and overheating. Applications: Residential Use: Homeowners can use these systems to store solar energy for use during the night or power outages. Commercial & Industrial Use: Businesses can use these systems to reduce demand charges or to provide backup power. Grid-Scale: Large energy storage systems can be used to stabilize the grid and facilitate the integration of renewable energy at a larger scale. Advantages: Sustainability: By storing renewable energy, these systems contribute to reducing carbon footprints and dependence on fossil fuels. Flexibility: They can be used in a wide range of applications, including residential, commercial, and large-scale energy storage. Cost Savings: Especially in commercial applications, they can help reduce energy costs by managing peak demand and reducing reliance on expensive grid power during peak periods.

Send Message
product image
Amaron Quanta 12V 18Ah Battery

The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features: 1. General Overview Brand: Amaron Quanta Battery Type: Sealed Lead-Acid (SLA) Battery Voltage: 12 Volts (V) Capacity: 18 Ampere-Hours (Ah) 2. Key Features Longer Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD). Maintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water). Vibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems. Wide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates. 3. Technical Specifications Voltage: 12V (Nominal) Capacity: 18Ah (Ampere-Hours) Dimensions: Length: 181 mm Width: 77 mm Height: 167 mm Weight: Around 5.2 to 5.5 kg (varies slightly based on exact model) Charge Voltage: 14.4V to 15.0V (during charging) Discharge Voltage: Typically 10.5V to 11.0V for complete discharge Self-discharge: Less than 3% per month at 25°C 4. Applications UPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics. Inverters: It can also be used in small-scale inverters to provide backup power to homes or offices. Telecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment. Solar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours. 5. Battery Design Features Valve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure. Deep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge. Absorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof. 6. Charge/Discharge Characteristics Charging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V. Discharge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan. 7. Advantages Longer Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use. Reliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments. Environmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills. 8. Maintenance Maintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended. Charging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan. 9. Warranty Amaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms. 10. Compatibility Compatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required. Charging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries. Conclusion The Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.

Send Message
product image
Vertiv 10kVA UPS

A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers. Vertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances. Here are some key features you might find in a Vertiv 10kVA UPS: Power Capacity: 10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment. Efficiency: Many Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs. Battery Type: Typically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions. Form Factor: These systems may come in both rack-mounted or tower configurations, depending on space requirements. Scalability: Some Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity. Monitoring and Control: Advanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software. Surge Protection and Isolation: Protects your sensitive equipment from power surges, voltage spikes, and electrical noise. Maintenance Bypass: Many UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices. Vertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.

Send Message
product image
10 kW solar system installed at M3M

Universal Power team has installed a 10 kW solar system 18 panel at M3M Key Details of the Installation: Solar System Size: 10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions. Number of Panels: 18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\'s total capacity by the number of panels. 10 kW / 18 panels = approximately 555 watts per panel. This indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems. Location – M3M: M3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint. Energy Production: The energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions. In an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity. Purpose: The solar power system could be installed for various reasons: To reduce energy bills by using clean solar energy. To support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient. To provide backup power or support the grid, especially in commercial or industrial settings. Benefits of a 10 kW Solar System: Reduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time. Environmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels. Increased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs. Government Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.

Send Message

Still searching for
other power backup systems?