Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
Emerson 40kVA Online UPS

The Emerson 40kVA Online UPS is a high-capacity uninterruptible power supply designed for critical applications where power reliability is essential. Here are the detailed specifications and features typically associated with this UPS model: Specifications Capacity: 40 kVA (kilovolt-amps) Input Voltage: Typically operates within a range of 380V to 480V AC. Output Voltage: Provides stable output, usually around 400V or 415V AC. Output Waveform: Pure sine wave output to ensure compatibility with sensitive electronic equipment. Input Frequency: Generally supports 50/60 Hz auto-sensing. Features Online Double-Conversion Technology: Ensures continuous power supply by converting incoming AC to DC and then back to AC, effectively isolating the load from power disturbances. LCD Display: Provides real-time information on operational status, including input/output voltage, battery status, and load percentage. Battery Type: Usually uses sealed lead-acid or lithium-ion batteries, depending on the specific model configuration. Charging Time: Full charge time can range from 4 to 8 hours, depending on battery type and condition. Runtime: Varies based on load; configurations can provide backup for several minutes to hours. Protection Features Overload Protection: Automatically shuts down the UPS to prevent damage if the load exceeds the rated capacity. Short-Circuit Protection: Protects against potential damage due to short circuits. Surge Protection: Guards connected equipment from voltage spikes and transients. Thermal Management: Equipped with fans and temperature sensors to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices, often including hardwired connections. Communication Ports: USB, RS232, and SNMP options for remote monitoring and management. Parallel Operation: Supports multiple UPS units to work together for enhanced capacity and redundancy. Applications Suitable for: Data centers Telecommunications Industrial applications Medical equipment Critical IT infrastructure Installation & Maintenance Installation: Typically requires professional installation due to its size and complexity. Maintenance: Regular maintenance checks are essential for battery health and overall system performance. Warranty Often includes a manufacturer’s warranty, typically ranging from 1 to 3 years, depending on the model and specific terms.

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
4 kva ups

The Luminous Cruze+ 4kVA is a high-performance online UPS that provides uninterrupted power for residential, commercial, and IT applications. Being an online UPS, it offers continuous, stable power with zero transfer time, making it ideal for sensitive equipment such as computers, servers, medical devices, and industrial systems. Key Features of Luminous Cruze+ 4kVA UPS Online Double-Conversion Technology: The Cruze+ 4kVA uses true online double-conversion technology, which ensures that your devices get clean, continuous, and regulated power without interruptions. In case of any fluctuations in the input voltage, the UPS immediately corrects it and ensures stable output voltage. Pure Sine Wave Output: The UPS provides pure sine wave output, which is ideal for sensitive devices, as it ensures minimal distortion and avoids any damage to electronic equipment, unlike square wave UPS systems that can harm certain types of equipment. High Efficiency: With a high conversion efficiency, the Cruze+ 4kVA reduces energy consumption and operational costs. This makes it not only a reliable backup solution but also energy-efficient. Wide Input Voltage Range: The Cruze+ UPS is designed to handle a wide input voltage range, which ensures that the system performs well even in areas with frequent voltage fluctuations, thereby reducing wear and tear on both the UPS and connected devices. Long Battery Life: Equipped with advanced battery management features, this UPS helps in optimizing the battery life, offering extended service periods even with frequent use. LCD/LED Display: The LCD display shows real-time status of the UPS, including input/output voltage, battery charge status, load percentage, and any faults. The LED indicators make it easier to monitor and understand the operational status at a glance. Battery Charging: The Cruze+ 4kVA UPS can handle multiple battery types, including lead-acid and VRLA batteries. It is equipped with an intelligent charging system that ensures batteries are charged efficiently without overcharging. Overload and Short Circuit Protection: Provides overload protection and short-circuit protection, ensuring that the system is safe from potential damage during power surges or faults. Battery Bank Options: The Cruze+ 4kVA is typically paired with a separate battery bank that provides the backup power. This can include Exide tubular batteries or Luminous batteries for optimal performance. Applications Residential: For powering sensitive equipment like computers, medical devices, and other electronics. Commercial: Protects servers, networking equipment, and office devices. Industrial: Suitable for critical industrial machines, automation systems, and control panels. Technical Specifications Capacity: 4kVA (4000 VA) Input Voltage: 140V - 300V (Wide input voltage range) Output Voltage: 220V / 230V (Pure sine wave) Output Frequency: 50 Hz ± 0.2 Hz Battery Charging Current: Adjustable (Typically 5-10A) Battery Type: Compatible with VRLA, Lead-Acid, and Tubular Batteries Backup Time: Depends on the battery capacity (typically, it can provide backup for 2-4 hours depending on the load and battery bank size). Dimensions (LxWxH): 465mm x 310mm x 115mm Weight: Around 15-18 kg (excluding battery) Warranty: 2 years on the UPS (can vary based on the model or region)

Send Message
product image
2 KVA UPS

Vertiv 2kVA UPS SB MODEL & LB MODEL The Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range: 1. Vertiv 2kVA SB (Standby) Series UPS The SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices. Key Features: Topology: Standby (Off-line) Power Rating: 2kVA / 2000VA Output Power: 1200W - 1600W (depending on model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Approximately 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB or serial ports for monitoring (depending on model) Form Factor: Typically Tower Additional Features: Surge protection Overload and short-circuit protection Low battery, overload, and fault indicators Automatic shutdown feature with optional software Audible alarms for power events (e.g., overload, low battery, fault) Compact design for easier placement in home office or small business environments Ideal Use Case: Home offices and small businesses Workstations, point-of-sale (POS) systems, and network equipment Consumer electronics that need surge protection and limited backup time 2. Vertiv 2kVA LB (Line-Interactive) Series UPS The LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology. Key Features: Topology: Line-Interactive Power Rating: 2kVA / 2000VA Output Power: 1400W - 1800W (varies by model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Around 4-6 hours to fully charge the battery Backup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown) Additional Features: Automatic Voltage Regulation (AVR) to correct voltage fluctuations Cold Start: Can be turned on without mains power (useful in power failure situations) Overload, short-circuit, and low battery protection LCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc. Enhanced battery management and energy-saving features to extend battery lifespan Audio and visual alerts for power failures, overloads, and battery issues Smart monitoring and management with optional software for power event logging and automatic shutdown Ideal Use Case: Small to medium-sized servers, workstations, and network equipment Sensitive equipment needing more precise power regulation IT infrastructures that require more consistent and reliable power protection Critical devices where frequent voltage fluctuations or outages could damage equipment Conclusion: SB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority. LB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.

Send Message
product image
Battery

The Amaron Quanta 12V 7Ah is a sealed lead-acid (SLA) battery commonly used in applications such as backup power systems, uninterruptible power supplies (UPS), security systems, and various other low-power applications. Here\'s a breakdown of its details: Key Specifications: Nominal Voltage: 12 Volts (V) Capacity: 7 Ampere-hours (Ah) at a rate of 20 hours (i.e., the battery can provide 0.35A of current for 20 hours). This is typical for deep-cycle applications, providing reliable performance over an extended period. Battery Type: Sealed Lead-Acid (SLA): Maintenance-free design. Can be installed in any orientation, though upright is recommended for optimal performance. Suitable for both float and cyclic applications. Dimensions: Length: 151 mm (5.94 inches) Width: 65 mm (2.56 inches) Height: 95 mm (3.74 inches) Weight: Approx. 2.3 kg (5.07 lbs) Terminal Type: F1 Faston connectors (0.187” wide), which are commonly used for quick connections. Operating Temperature: Discharge: -15°C to +50°C (5°F to 122°F) Charge: 0°C to +40°C (32°F to 104°F) Float Life: Typically 3-5 years in float (backup power) applications. Self-Discharge: SLA batteries typically have a low self-discharge rate of about 3-5% per month at 25°C, meaning they retain their charge relatively well when not in use for extended periods. Charge Voltage: Standard Charging Voltage: 13.5 to 13.8V (constant voltage charging) Maximum Charging Voltage: 14.4V Recommended Float Charging Voltage: 13.5V Cycle Life: Typically offers about 200-300 cycles at 100% discharge. The cycle life increases with lower depth of discharge (DoD). Applications: UPS Systems: To provide backup power for computers, networking equipment, and other devices. Solar Power Systems: As a small energy storage option in off-grid or backup solar systems. Alarm Systems: For providing power in case of a mains failure. Electric Vehicles & Mobility Scooters: In some cases for small EVs or battery-powered mobility solutions. Power Tools & Other Low Power Systems: To provide compact, reliable energy for tools and other devices. Safety & Maintenance: Maintenance-Free: No need to add water or maintain the electrolyte levels, as the battery is sealed. Overcharge Protection: Built-in mechanisms to prevent overcharging that could lead to damage or overheating. Overcurrent Protection: Built-in to prevent damage due to short circuits or excessive current. Warranty: Typically 1-2 years depending on the brand and country of purchase. Storage & Handling: Storage Temperature: Store in a cool, dry place, ideally between 15°C and 25°C. Do not store in a fully discharged state, as this can significantly reduce the lifespan of the battery. Regular Maintenance: If not in use for extended periods, check the battery voltage periodically and recharge it if necessary. The Amaron Quanta 12V 7Ah battery is designed for reliability and versatility, suitable for a variety of applications that require backup power or a small energy storage solution.

Send Message