Gurugram
+918076792323

'power continuity'

Items tagged with 'power continuity'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Vertiv 20 Kva Ups

The Vertiv 20 kVA UPS is typically represented by models such as the Liebert GXT5. This UPS is designed for critical applications, providing reliable power protection and ensuring the continuity of operations in environments such as data centers, telecommunications, and industrial applications. Below are the key details and specifications for the Vertiv 20 kVA UPS: Key Features Double Conversion Technology: Provides a clean and stable output voltage, protecting connected equipment from power disturbances. High Efficiency: Offers efficiencies of up to 95% in double conversion mode and even higher in eco-mode, reducing energy costs. Scalability: Modular design allows for easy scalability to meet growing power needs. Flexible Configuration: Supports various input and output configurations, making it adaptable to different environments. Advanced Monitoring and Management: Equipped with an LCD display for real-time monitoring and management of UPS status and performance. Battery Management: Intelligent battery management features extend battery life and optimize performance. Compact Design: Space-saving design suitable for various installation environments. Technical Specifications Capacity: 20 kVA / 20 kW Input Voltage: Typically supports 208 V or 400 V three-phase systems Output Voltage: Configurable options, commonly 120 V or 208 V Form Factor: Tower or rack-mounted options available Battery Type: Sealed lead-acid or lithium-ion options, depending on the model Runtime: Configurable based on battery size and load; external battery cabinets can be added for extended runtime Communication Ports: USB, RS-232, and optional SNMP for network management Applications Data Centers: Protects critical IT infrastructure from power interruptions. Telecommunications: Ensures continuous operation of communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Conclusion The Vertiv 20 kVA UPS is a reliable solution for businesses that require uninterrupted power supply and high efficiency. Its advanced features and flexible configurations make it suitable for a wide range of applications, ensuring that critical systems remain operational during power disturbances. For specific model details, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
UPS

Vertiv offers the 30kVA UPS models designed for high availability and critical power applications. Here’s a detailed overview of the key features and specifications: Key Model: 1. Vertiv Liebert EXS UPS: Power Rating: 30kVA / 30k - Input/Output Voltage: 400V in / 400V out, three-phase Technology: Online double conversion for superior power quality Power Factor: High power factor (0.9) for efficient energy usage Form Factor: Rack-mounted or tower configuration Features: Modular Design: Allows for easy scalability and maintenance without downtime Advanced Monitoring: Integrated monitoring capabilities with the Vertiv monitoring platform for real-time insights Battery Management: Intelligent battery management system to optimize battery life and performance User -Friendly Interface: Touchscreen display for easy navigation and monitoring of UPS status Energy Efficiency: Designed to meet or exceed ENERGY STAR certification for energy savings Applications: Data Centers: Provides reliable power to critical IT infrastructure Healthcare Facilities: Ensures uninterrupted power for life-saving medical equipment Telecommunications: Supports network operations and communications during power failures Industrial Applications: Protects sensitive equipment and processes from power disturbances Technical Specifications: Input Connection Types: IEC 320 EN 60320 C19, IEC 60320 C13 Output Connection Types: 6 x IEC 60320 C19, 2 x IEC 60320 C13 Operating Environment: Suitable for both indoor and outdoor installations, with temperature and humidity controls Advantages: High Availability: Designed for maximum uptime and reliability in critical applications Flexible Configuration: Can be customized to meet specific power requirements and installation environments Robust Protection: Offers comprehensive protection against power anomalies, ensuring equipment safety Vertiv\'s 30kVA UPS solutions are engineered to deliver reliable power protection and management, ensuring operational continuity and efficiency in demanding environments.

Send Message
product image
ups

Vertiv offers several models of 10kVA Uninterruptible Power Supplies (UPS) designed for critical power applications. Here’s a comprehensive overview of the key models and their features: Key Models: 1. Vertiv Liebert GXT5 UPS: Power Rating: 10kVA / 10kW Input/Output Voltage: 230V in / 230V out, single-phase Technology: Online double conversion for continuous power conditioning Power Factor: Unity power factor (1.0) for efficient load management Form Factor: Tower/rack mount Features: Remote Monitoring: Built-in Vertiv RDU101 communications card for remote monitoring and management Software Integration: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Scalable Runtime: Options for external battery cabinets to extend runtime during outages Display: Intuitive gravity sensing full-color LCD display for easy status monitoring Energy Efficiency: ENERGY STAR 2.0 certified for reduced energy consumption Applications: Data Centers: Protects critical IT infrastructure from power disturbances Healthcare: Ensures reliable power for medical equipment Telecommunications: Supports network reliability during outages Industrial: Safeguards machinery and sensitive equipment Technical Specifications: Input Connection Types: IEC 320 EN 60320 C13, IEC 60320 C19 Output Connection Types: 4 x IEC 60320 C19 Operating Environment: Designed for both centralized and edge computing applications Advantages: High Efficiency: Reduces operational costs with high power efficiency Robust Protection: Protects against all types of power disturbances, extending battery life Flexible Deployment: Suitable for various installation environments, including rack and tower configurations Vertiv\'s 10kVA UPS solutions are engineered to provide reliable power protection and management for critical applications, ensuring operational continuity during power interruptions.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Amaron industrial batteries

Amaron industrial batteries are designed for heavy-duty applications and are known for their reliability, performance, and long service life. Here’s a detailed overview of their features, types, specifications, and applications: Key Features Robust Construction: Designed to withstand harsh industrial environments, these batteries are built to resist vibrations, shocks, and extreme temperatures. High Cycle Life: Amaron industrial batteries are engineered for deep cycling, offering excellent performance in frequent charge and discharge cycles. Maintenance-Free Options: Many models are sealed and maintenance-free, reducing the need for regular upkeep. Versatile Applications: Suitable for a variety of industrial uses, from backup power to specialized equipment. Efficiency: High charging efficiency allows for quicker recharge times and optimal energy utilization. Corrosion Resistance: Constructed with materials that resist corrosion, enhancing longevity and performance. Types of Amaron Industrial Batteries Amaron Quanta: Use: Ideal for industrial applications, including UPS systems, telecommunications, and other critical power needs. Features: Available in both 12V and 2V configurations, designed for high capacity and reliability. Amaron SMF (Sealed Maintenance-Free): Use: Suitable for various industrial applications where maintenance is challenging. Features: Provides reliable power with low self-discharge rates, ensuring long shelf life. Amaron AGM Batteries: Use: Ideal for high-performance applications, including industrial machinery and equipment. Features: Offers excellent power delivery and deep cycle capabilities. Specifications Voltage: Available in both 12V and 2V configurations. Capacity: Ranges from 100Ah to over 300Ah, depending on the specific model. Sizes: Various sizes are available to fit different industrial setups and requirements. Applications Uninterruptible Power Supply (UPS): Used in UPS systems for critical applications, ensuring power continuity. Telecommunications: Powers telecom equipment and towers, providing reliable backup. Material Handling Equipment: Suitable for forklifts, pallet jacks, and other industrial vehicles. Renewable Energy Systems: Can be used in conjunction with solar or wind energy systems for energy storage. Mining and Construction: Ideal for equipment used in harsh conditions and demanding environments. Conclusion Amaron industrial batteries are designed for performance and reliability in demanding applications, making them a preferred choice for various industries. For specific models, detailed specifications, or further information, it’s best to check the Amaron website or consult with local distributors. If you have specific questions or need more details about a particular model, feel free to ask!

Send Message
product image
Vertiv Data Center Ups

Vertiv is a well-known provider of critical digital infrastructure and continuity solutions, including uninterruptible power supplies (UPS) for data centers. They offer a variety of UPS systems designed to meet the needs of different types of data centers, from small edge installations to large enterprise facilities. Here are some of the main types of UPS systems offered by Vertiv: 1. Single-Phase UPS Vertiv Liebert GXT5: A compact UPS designed for small to medium data centers, offering high efficiency and power density. Vertiv Liebert PSI5: A line-interactive UPS that provides reliable power protection for small IT environments. 2. Three-Phase UPS Vertiv Liebert EXS: A modular UPS solution that offers scalability and flexibility for medium to large data centers. Vertiv Liebert APM: A highly efficient UPS designed for large enterprise environments, providing advanced features and high availability. Vertiv Liebert NXC: A robust UPS solution designed for mission-critical applications, offering high efficiency and reliability. 3. Modular UPS Vertiv Liebert DPA: A modular UPS system that allows for incremental capacity upgrades, making it ideal for growing data centers. 4. Flywheel UPS Vertiv Liebert FPC: A flywheel energy storage system that provides short-term backup power and is often used in conjunction with traditional UPS systems for enhanced reliability. 5. Lithium-Ion UPS Vertiv Liebert APS: A UPS system that utilizes lithium-ion battery technology for longer life and reduced maintenance compared to traditional lead-acid batteries. 6. Eco-Friendly Solutions Vertiv also focuses on energy-efficient and environmentally friendly solutions, such as systems that comply with various sustainability standards and regulations. Key Features Scalability: Many Vertiv UPS systems are designed to be modular, allowing for easy expansion as data center needs grow. Efficiency: High-efficiency designs help reduce energy costs and improve overall sustainability. Advanced Monitoring: Vertiv offers solutions with integrated monitoring capabilities, allowing for real-time performance tracking and proactive maintenance alerts. Redundancy Options: Many systems support N+1 or 2N configurations for enhanced reliability. Applications Enterprise Data Centers: Large facilities requiring high availability and redundancy. Edge Computing: Solutions designed for smaller, distributed data centers. Telecommunications: Power protection for critical telecom infrastructure. Healthcare: Ensuring uptime for critical medical equipment and data. When choosing a UPS system, it's essential to consider factors such as load requirements, runtime needs, efficiency, and the specific environment in which the UPS will operate. For the most accurate and tailored solutions, it's advisable to consult with a Vertiv representative or a certified distributor.

Send Message

Still searching for
power continuity?