Gurugram
+918076792323

'power cuts'

Items tagged with 'power cuts'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Amaron Tubular Battery

Amaron is a well-known brand, and they manufacture various types of batteries, including tubular batteries. These batteries are primarily used for inverter applications (backup power for homes and businesses) and for solar energy systems. Key features of Amaron Tubular Batteries: Long Life: Tubular batteries are known for their long service life, and Amaron's version is no different. The tubular plates offer better performance and longer discharge cycles. Durability: Amaron batteries are designed to handle harsh conditions and provide consistent power over extended periods. Deep Discharge: Tubular batteries are ideal for deep discharge applications, which means they can be used for long durations without damaging the battery. Low Maintenance: Although they are flooded lead-acid batteries, Amaron batteries generally require less maintenance compared to traditional batteries. Fast Charging: They have the ability to charge faster compared to flat plate batteries, making them a good choice for areas with frequent power cuts. Amaron offers a variety of options in this category, depending on your energy needs and system configuration. The exact specifications (capacity, voltage, etc.) would depend on the model you are considering.

Send Message
product image
Amaron Current Tall Tubular Battery

The Amaron Current Tall Tubular Battery with a specification of 12 Volts and 150 Ampere Hours (Ah) is designed primarily for inverter applications and is known for its durability and efficiency. Here are the key features and specifications of this battery: Key Specifications Model: Amaron Current Tall Tubular Battery Type: Tall Tubular Lead Acid Battery Voltage: 12 V Capacity: 150 Ah Weight: Approximately 40-45 kg (exact weight may vary) Dimensions: Typically around 500 x 190 x 400 mm (length x width x height, but check specific dimensions) Warranty: Usually 48 months (36 months replacement and 12 months pro-rata) Key Features Tall Tubular Design: This design enhances the battery's life and performance, making it suitable for long backup times. Low Maintenance: Designed to require minimal maintenance, with features that reduce water loss. High Durability: Built to withstand deep discharge cycles, making it ideal for areas with frequent power cuts. Excellent Charge Acceptance: Capable of accepting a quick charge, which is beneficial for inverter applications. Corrosion Resistance: The battery is designed to resist corrosion, enhancing its lifespan. Applications Inverter Systems: Ideal for home and office inverter systems, providing reliable backup power. Solar Power Systems: Can be used in solar energy storage applications. Telecommunication Equipment: Suitable for telecom towers and other critical applications requiring reliable power. Industrial Applications: Used in various industrial equipment that requires a stable power supply. Conclusion The Amaron Current Tall Tubular Battery (12V, 150Ah) is an excellent choice for users looking for a reliable and efficient power backup solution, particularly in areas with frequent power interruptions. Always check with local suppliers for the most accurate pricing and availability, as well as warranty details.

Send Message
product image
AMARON QUANTA VRLA SMF BATTERY

The Amaron Quanta VRLA SMF Battery 100 Ah is designed for various applications, particularly for use in uninterruptible power supply (UPS) systems and other backup power solutions. Here are the key specifications and features of this battery: Key Specifications Model: Amaron Quanta 100 Ah Type: VRLA (Valve Regulated Lead Acid) Sealed Maintenance Free (SMF) Voltage: 12 V Capacity: 100 Ah Weight: Approximately 30-35 kg (exact weight may vary) Dimensions: Typically around 407 x 173 x 220 mm (length x width x height) Operating Temperature: 0 – 40 °C Warranty: Usually 24 months (check specific terms) Key Features Maintenance-Free: The VRLA technology ensures that the battery does not require regular maintenance, such as topping up with water. High Performance: Designed for high discharge rates, making it suitable for applications that require reliable power. Durability: Built to withstand harsh conditions and has a long service life. Quick Recharge: Capable of accepting a fast charge, which is beneficial in environments with frequent power cuts. Safety Features: Equipped with safety valves to prevent overpressure and leakage. Applications UPS Systems: Ideal for providing backup power to critical systems during outages. Telecommunication Equipment: Used in telecom towers and data centers. Solar Power Systems: Can be used in solar energy storage applications. Industrial Applications: Suitable for various industrial equipment requiring reliable power. Conclusion The Amaron Quanta VRLA SMF Battery 100 Ah is a reliable choice for users looking for a robust and maintenance-free power solution. It is particularly well-suited for applications that demand consistent performance and durability. Always check with local suppliers for the most accurate pricing and availability.

Send Message
product image
AMARON QUANTA TUBULAR BATTERY

The Amaron C10 150AH Quanta Tubular Battery is designed for inverter applications and features the following specifications: Capacity: 150 Ah Voltage: 12 V Type: Tubular Protection: Over temperature, deep discharge, and short circuit Backup Time: Approximately 2 hours This battery is built for high performance and reliability, making it suitable for various power backup needs. Key Features of Amaron C10 150AH Quanta Tubular Battery Construction: Extra thick plates for enhanced longevity Maintenance: Low maintenance requirements due to special alloy composition Charge Acceptance: Excellent charge acceptance, ideal for frequent power cuts Level Indicators: Easy maintenance with built-in level indicators Power Cut Resilience: Designed to withstand frequent and prolonged power outages Specifications Brand: Amaron Model: C10 Voltage: 12V DC Capacity: 150Ah Type of Battery: Tall Tubular Inverter Compatibility: Supports all brands and types of inverters Factory Charged: Yes Warranty: 48 months (36 months replacement and 12 months pro-rata) This battery is an excellent choice for users looking for a reliable and efficient power backup solution, particularly in areas with frequent power interruptions.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Online UPS on Rent in Delhi NCR

Universal Power System Leading Service Provider of Online UPS on Rent/Hire in Delhi (NCR) UPS on Rent in Delhi NCR How to choose the right UPS On Rent according to the use or application? A UPS is not only designed to alleviate power cuts. It also serves to stabilize the electrical voltage and eliminate electrical parasites. The UPS is an important link in the security of computer systems. Its main mission is to take over when power cuts occur, leaving users with time to save work in progress. The cuts are not the only incidents that these devices must face. Filtering, as well as voltage regulation, is also part of the functions that are important to ensure. A good UPS must guarantee the continuity of the electrical supply to the devices, as well as ensure that the current is of good quality. A UPS is composed of three parts: The rectifier, that transforms the alternating current into a direct current destined to charge the batteries and to feed the UPS. The batteries that store energy. Different types of UPS are suitable for different applications, and there is no single type of UPS that is ideal for all applications. With the variety of UPS topologies on the market today, these guidelines will help clarify the confusion about how each topology operates and the advantages and disadvantages of each. After this you an easily choose ups on rent in DELHI NCR There are significant differences in the design of UPS among the products available in the market, with theoretical and practical advantages for different approaches. For this reason, it is convenient to know which the key points in which are a purchasing manager or responsible for the data center should be set to choose a reliable ups on rent in DELHI NCR, according to the recommendations of Schneider Electric: Look for a UPS that operates in ecological mode ("green") of high efficiency. The result is a reduction in energy consumption, including the cost of cooling. Flexibility of being convertible, so that it can be easily installed in a rack or in the form of a tower. Easy to configure, monitor and manage locally through an advanced LCD screen. Structure that allows the use of intelligent modules of external batteries to increase the autonomy time of the UPS automatically. Features that provide intelligent, advanced and automatic battery management. This allows recharging them of fast and safe form, lengthens its useful life and notifies to the user of the date for the replacement of the batteries. Advanced features of monitoring and control of your energy consumption in real time. Easy to configure the groups of controlled sockets, so that they turn on or off independently. In this way, for example, in the case of a failure in the power supply, loads that are less critical can be automatically turned off, thus increasing the equipment's autonomy time. These features will allow you to compare different equipment and make a better decision when you go for ups on rent in DELHI NCR, to incorporate into your infrastructure equipment that can provide long-term benefits, with the security of having the best backup and the peace of mind to manage the energy of your equipment. In Our Team, We have Procuring Agents Quality Controllers Management Personnel Administrative Staff Marketing & Sales Staff Logistic Personneling of UPS Brought Out Spares Reasons to Choose Us Having 22 years of rich experience of providing power backup solutions for high critical sectors Incredible services that matters and deserve you the best 24 by 7 stock availablity of wide range of ONLINE UPS and BATTRIES< Only provide and install branded ONLINE UPS and BATTRIES at very lowest and compititive prices Highly efficient and qualified technical engineers to resolve the breakdown

Send Message

Still searching for
power cuts?