Gurugram
+918076792323

'receptacle type'

Items tagged with 'receptacle type'

product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
6 kva ups

The Vertiv 6 kVA UPS models, such as the Liebert GXT5 and Liebert GXT MTX+, offer robust power protection for critical equipment. Here are the key specifications and details: Vertiv Liebert GXT5 6 kVA/6 kW Model: Liebert GXT5 Capacity: 6 kVA / 6 kW Input Voltage: 208/120V Output Power Factor: 1.0 (Unity) Form Factor: Rack/Tower Dimensions: Depth: 25.6 inches Rack Height: 4U Weight: Approximately 125.60 lbs Backup/Run Time: Half Load: 9.50 minutes Full Load: 3.50 minutes Transfer Time: 0 ns (no break) Receptacle Type: Hardwired Bypass Switch: Automatic & Manual; Internal Emergency Power OFF: Yes Audible Noise: Less than 55 dBA at 1 meter Vertiv Liebert GXT MTX+ 6 kVA Model: Liebert GXT MTX+ Output Power Factor: 0.8 Input Voltage Range: 110 — 300 Vac Charging Design: 4 Stage Extendable Charging for optimized battery performance Adjustable Battery Charging Current: 1/2/4/6 Amps based on battery capacity Compact Design: Best-in-class online UPS system General Features Type: Online Double Conversion UPS Protection: Protects against outages and all types of power disturbances Applications: Suitable for centralized and edge locations, ideal for critical equipment These UPS systems are designed to ensure reliable power supply and protect sensitive electronic equipment from power disturbances, making them essential for data centers, telecommunications, and other critical applications.

Send Message
product image
UPS

APC offers a range of UPS (Uninterruptible Power Supply) systems, with the Smart-UPS series being particularly popular for providing reliable power protection. Here are some key specifications and details about the APC Smart-UPS models: General Specifications: Types: Line Interactive and On-Line models - Input Voltage: Typically 120V or 230V depending on the model Output Voltage: Pure sine wave output for compatibility with sensitive equipment Form Factor: Available in tower and rack-mount configurations Key Models: 1. APC Smart-UPS C Series: Ideal For: Small and medium businesses Features: Pure sine wave output LCD status display for real-time monitoring Multiple status indicators with load and battery bar graphs Configurable for tower or rack installation Models: SMC1000: 1000VA/670W SMC1500: 1500VA/1000W 2. APC Smart-UPS SMT Series: Features: Multi-function LCD screen DB-9, RS-232, Smart-Slot, and USB interface ports Extended runtime options with additional battery packs Models: SMT750: 750VA/500W SMT1000: 1000VA/670W SMT1500: 1500VA/1000W SMT2200: 2200VA/1980W 3. APC Smart-UPS SMX Series: Features: Similar to SMT series but with scalable runtime Extended run internal batteries Models: SMX750: 750VA/600W SMX1000: 1000VA/800W Key Features Across Models: Pure Sine Wave Output: Ensures compatibility with active PFC servers and sensitive electronics. LCD Display: Provides essential UPS status information at a glance. Multiple Output Receptacles: Varies by model, typically includes multiple 5-15R and 5-20R outlets. SmartConnect: Some models offer cloud monitoring capabilities for remote management. Applications: Data Centers: Protects critical servers and networking equipment. Telecommunications: Ensures reliable power for communication systems. Industrial Applications: Supports machinery and equipment during power interruptions. Advantages: Reliable Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Versatile Installation Options: Suitable for various environments and configurations. APC UPS systems are designed to provide robust power protection and management solutions for a wide range of applications, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
Exide Bike Battery In Bhiwadi

Exide bike batteries are designed for high performance and durability in two-wheelers. Here are key details: Type: VRLA (Valve Regulated Lead Acid) and conventional flooded batteries, suitable for different bike models. Features: Maintenance-free, spill-proof, vibration-resistant, and designed for quick starting power. Applications: Used in motorcycles, scooters, and other two-wheelers for reliable starting and backup power. Durability: High resistance to extreme temperatures and rough road conditions. Maintenance: Low maintenance with easy water level checks (for conventional types). Exide is a trusted brand for two-wheeler batteries, known for its long-lasting performance and reliability.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.

Send Message
product image
Microtek inverter In Bawal

Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points: Types: Available in pure sine wave, square wave, and modified sine wave models to suit different needs. Applications: Used for home, office, and industrial backup power systems. Features: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems. Compatibility: Works well with various battery types, including lead-acid and lithium-ion. Durability: Built to withstand power fluctuations and extreme conditions. Microtek is known for its durable and cost-effective inverters, widely used across India and other regions.

Send Message
product image
Amaron Tubular Battery In Faridabad

Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points: Design: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions. Applications: Commonly used in inverters, solar power systems, and other backup power solutions. Durability: Known for high resistance to corrosion and low maintenance requirements. Performance: Excellent charge retention and high power output, even in harsh conditions. Maintenance: Requires periodic checking of water levels and occasional equalization charging. Amaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.

Send Message
product image
Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message