Gurugram
+918076792323

'relay contacts'

Items tagged with 'relay contacts'

product image
5SC UPS

The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports. Key Specifications: Power Ratings: 500 VA to 1500 VA Output: Pure sine wave Connectivity: USB, serial, and relay Battery Type: Sealed lead-acid, maintenance-free Dimensions: Varies by model Weight: Approximately 34 lbs to 50 lbs depending on the model For more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices. Key Features: Power Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA Output Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems Battery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50% Connectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux) Display: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode Design: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR) Performance and Reliability: Run Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads Warranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment Noise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit User Experience: Setup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface Software: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead Customer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation

Send Message
product image
40kVA UPS

The Vertiv 40kVA UPS models, such as the Liebert ITA and EXS series, offer robust power protection for critical applications. They feature a power capacity of 40 kVA, double conversion technology, and options for both three-phase and single-phase outputs, ensuring reliable performance and flexibility in installation. Key Specifications: Power Capacity: 40 kVA (40 kW). Input Voltage Range: Typically 176 V AC - 288 V AC. Output Voltage: Configurable options, often 208V or 220V. Form Factor: Available in rack or tower configurations. Efficiency: High efficiency ratings, often exceeding 95%. Communication: Equipped with Vertiv IntelliSlot for SNMP, Modbus, or Relay communication. Battery Type: Generally uses lead-acid batteries with options for extended runtime. Applications: Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
Lithium-ion battery repairing services

Lithium-ion battery repairing services focus on diagnosing, repairing, and refurbishing lithium-ion batteries used in various applications, such as electric vehicles, consumer electronics, and renewable energy systems. Here’s a comprehensive overview of such services: Overview of Services Battery Diagnosis Testing: Assessing the battery's health using specialized equipment to measure voltage, capacity, and internal resistance. Fault Identification: Identifying issues such as cell imbalance, dead cells, or internal short circuits. Repair Services Cell Replacement: Replacing defective cells within a battery pack to restore capacity and performance. Rebalancing: Balancing individual cells to ensure even charging and discharging, which prolongs battery life. Reconditioning: Cleaning and refurbishing battery contacts and connections to improve performance. Battery Management System (BMS) Repair BMS Testing: Checking the functionality of the BMS that monitors and manages the battery’s state. BMS Replacement: Replacing faulty BMS units to ensure safe and efficient battery operation. Battery Pack Rebuilding Repackaging: Rebuilding the entire battery pack, often using new or refurbished cells to increase capacity and lifespan. Re-encapsulation: Ensuring that the battery pack is securely encapsulated and insulated for safety. Data Recovery Data Retrieval: Recovering data from battery management systems or associated devices if they have become corrupted or lost. Common Applications Consumer Electronics: Smartphones, laptops, and tablets. Electric Vehicles: Cars, bikes, and scooters. Power Tools: Drills, saws, and other rechargeable tools. Renewable Energy Systems: Solar storage batteries and backup systems. Medical Devices: Mobility aids, monitoring devices, etc. Benefits of Repairing Lithium-Ion Batteries Cost-Effective: Often cheaper than purchasing a new battery. Environmental Impact: Reduces electronic waste by extending the life of existing batteries. Performance Restoration: Can restore batteries to near-original performance levels. Considerations Safety: Lithium-ion batteries can be hazardous; repairs should only be performed by qualified technicians with appropriate safety measures. Warranty: Check if repairing affects any existing warranty on the device or battery. Service Providers: Look for reputable service providers with good reviews and experience in lithium-ion battery technology. Typical Process Assessment: Customers bring in or ship batteries for assessment. Quote: After diagnosis, a cost estimate for repairs is provided. Repair: Upon approval, repairs are conducted, often within a specified timeframe. Testing: Post-repair testing to ensure the battery is functioning correctly. Return: The repaired battery is returned to the customer with information on care and maintenance. Finding a Service Provider Online Search: Look for local or online repair services specializing in lithium-ion batteries. Certifications: Ensure the service provider is certified and experienced in battery technology. Reviews: Check customer reviews and ratings for quality assurance. Conclusion Lithium-ion battery repairing services provide essential support for maintaining and extending the life of various battery-operated devices. By selecting a qualified service provider, customers can achieve significant savings and environmental benefits while ensuring their devices operate reliably.

Send Message
product image
Vertiv Hiplus 80-800 KVA Online Ups

UPS Renting Services HIPULSE UPS (80-800 KVA) It is a range of uninterruptible power supply (UPS) systems manufactured by a company called HIPULSE. These UPS systems are designed to provide reliable and continuous power protection for a wide range of applications, from small to large-scale industrial and commercial environments. The HIPULSE UPS range typically covers a power capacity range of 80-800 kilovolt-amperes (kVA). Most of Benefits from Universal Power System: Features: On-Line Double C???onversion IGBT-based PWM Inverter Wide input voltage tolerance (+15 / -15%) Wide input frequency tolerance (45Hz-65Hz) Capability to handle: - High crest factor loads - 100% non-linear loads - 100% unbalanced loads Built-in maintenance bypass (Single and 1+N Models) Common battery sharing kit (optional) with 1+1 configuration Built-in maintenance bypass (Single and 1+N Models) Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA UPS Renting Services UPS Renting Services S7400 UPS (10-400 KVA) THE S7400 UPS IS A SERIES OF UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEMS MANUFACTURED BY AN UNDISCLOSED COMPANY. THESE UPS SYSTEMS ARE DESIGNED TO PROVIDE RELIABLE AND CONTINUOUS POWER PROTECTION FOR A WIDE RANGE OF APPLICATIONS. THE S7400 SERIES TYPICALLY COVERS A POWER CAPACITY RANGE OF 10 KVA TO 400 KVA. Features: High performance IGBT PWM(Pulse Wave Modification) technology for pure sinewave output LBS configuration for super critical loads True parallelability up to six modules Netcom kit for remote monitoring BMS Connectivity through modbus Remote alarm monitor (RAM) Hardware for Fault Diagnostic Unit (FDU), data logger and power monitoring software Communication card for dial-up monitoring UPS Series 7400 The Series 7400 UPS offers True On-line Field Proven UPS system to maximize Uptime of your Critical Application. The Series 7400 offers a wide range from 10 kVA to 750 kVA single phase systems. The Series 7400 UPS System has a proven track - record of unmatched reliability to support your sensitive and costly equipment, offering maximum availability to virtually any application. The Series 7400 is carefully designed to address the “load power factor” (0.7 lagging upwards) and “non linearity” that critical applications demand. In-built output isolation transformer To offer galvanic isolation between your critical application and the Mains, while feeding the load through the Inverter. Battery Circuit Breaker (BCB): To ensure “Safety” and to protect your “Battery Life”, unlike using DC Isolator. Usage of BCB is much safer in terms of personal hazards on a running system than a DC Isolator. Under Voltage Trip coil of BCB prevents deep-discharging of battery, which cannot be achieved by a DC Isolator. RS-232 Serial port : For carrying out on-line monitoring of Alarm and Status. Optional attachments such as IBM-AS 400 Interface Card/ Relay Interface Card help you to integrate the UPS with your network effectively. High efficiency performance High reliability to maximise system availability Handles 3:1 crest factor loads without de-rating

Send Message

Still searching for
relay contacts?