Gurugram
+918076792323

'sic card'

Items tagged with 'sic card'

product image
UPS

The VERTIV Liebert ITON CX 1000VA UPS is a line-interactive uninterruptible power supply designed for home and small office use. Below are the details regarding its unboxing and quick testing. Unboxing Details Packaging: The UPS comes securely packaged to prevent damage during transit. Ensure to check for any visible signs of damage upon receipt. Included Items: VERTIV Liebert ITON CX 1000VA UPS unit User manual and installation guide Power cord with UK outlet Warranty card Initial Inspection: Check the UPS for any physical damage. Verify that all components are included as per the manual. Quick Test Procedure Setup: Place the UPS in a well-ventilated area. Connect the power cord to the UPS and plug it into a wall outlet. Power On: Press the power button to turn on the UPS. Observe the LED indicators: Green Light: Indicates AC mode (normal operation). Red Light: Indicates a fault condition. Battery Mode Test: To test the battery mode, disconnect the UPS from the wall outlet. Ensure that the UPS switches to battery mode automatically. Check the runtime by connecting a load (e.g., a computer) and monitor how long the UPS can sustain power. Load Testing: Connect a load that draws approximately 120W (e.g., a standard desktop computer). Monitor the backup time, which should be around 30 minutes under this load. Recharge Time: After the test, reconnect the UPS to the wall outlet. Note that the typical recharge time is 6-8 hours to reach 90% capacity. Key Specifications Power Capacity: 1000 VA / 600 Watts Input Voltage: 220/230 VAC Output Waveform: Simulated Sine Wave Transfer Time: 2-6 ms Battery Type: 12 V / 7 Ah x 2 Typical Backup Time: 30 minutes at 120W load Dimensions: 369 x 141 x 160 mm Weight: 10 kg Conclusion The VERTIV Liebert ITON CX 1000VA UPS is a reliable solution for power protection in small setups. The unboxing and quick test confirm its functionality and performance, making it a suitable choice for users needing uninterrupted power supply for their electronic devices. Always refer to the user manual for detailed instructions and safety precautions.

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
UPS

The Emerson/Vertiv 1kVA UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications **Brand **: Emerson/Vertiv Model Name/Number: 1kVA UPS Capacity: 1kVA/ 0.8KW (1in - 1out) Input Voltage: 140-300VAC at 100% load; 100VAC - 300VAC on 50% load Output Voltage: 230VAC (single phase) Application Areas Small to Medium-Sized Businesses Home Offices Small Server Rooms Point of Sale (POS) Systems ATMs Medical Equipment Security Systems Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message
product image
UPS

The Vertiv Emerson Liebert Powerbank 600 1x1 6Kva Online UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications Brand: Vertiv Emerson Model Name/Number: Liebert POWERBANK 600 6KVA Online UPS Capacity: 6KVA/ 6KW (1in - 1out) Input Voltage: 76 -288VAC at 100% load; 100VAC - 288VAC on 50% load Output Voltage: 220/230/240VAC (single phase) Application Areas Edge Networks Manufacturing Units Motarised Load Jerk Load Industrial & Machine Applications Data Centers Analytical instruments Server Farms Workstations Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc., ) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message
product image
UPS

The Vertiv 10kVA UPS is a high-performance uninterruptible power supply system designed to provide continuous power conditioning and protection for mission-critical systems. It's available in various models, including the Liebert GXT5, Liebert EX L, and Liebert NX. Technical Specifications Load Capacity (VA): 10000 VA Output Voltage: 120 V AC, 208 V AC Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds 150% (impact load) minimum 200 ms Management Features Bypass Switch: Automatic & Manual, Internal Remote Monitoring: Built-in Vertiv RDU101 communications card Software: Free Vertiv Power Insight software for monitoring and management Physical Characteristics Form Factor: Tower/Rack Mount Dimensions: Not specified Weight: Not specified Certifications and Compliance ENERGY STAR 2.0 Certified: Yes Other Certifications: Not specified Additional Features Scalable Runtime Options: Matching external battery cabinets for extended runtime LCD Display: Intuitive gravity sensing full-color LCD display

Send Message
product image
Vertiv 40Kva Online Ups In udhyog vihar Gurgaon

The Vertiv 40 kVA UPS is designed to provide robust power protection and management for critical infrastructure in data centers, IT rooms, and industrial applications. It ensures that sensitive equipment remains operational during power disturbances. Key Specifications Power Rating: 40 kVA Input Voltage: Typically 380/400/415V (three-phase) Output Voltage: 380/400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion or line-interactive Efficiency: Up to 96% in eco mode Total Harmonic Distortion (THD): <5% at full load Battery and Runtime Battery Type: Typically uses VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Capacity: Varies based on configuration; options for extended runtime Charging Time: Usually 4-8 hours for a full charge (depending on battery type) Runtime: Configurable based on load; options for longer runtimes available Features Redundancy: N+1 configuration allows for increased reliability. Scalability: Can be expanded with additional units for greater capacity or redundancy. Smart Monitoring: Advanced LCD display for real-time monitoring of UPS status, input/output voltage, load percentage, battery status, and alarms. Communication Options: SNMP, USB, RS232, and optional network management cards for remote management. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Physical Characteristics Dimensions: Varies by model; generally within 60-80 cm in width and depth Weight: Approximately 200-400 kg (depends on battery configuration) Cooling: Typically air-cooled; ensure adequate airflow in the installation environment. Benefits Power Quality: Provides clean and stable power to connected equipment. High Availability: Ensures uptime for critical loads. Flexibility: Suitable for a wide range of applications including data centers, telecommunications, and industrial systems. User-Friendly: Intuitive interface and management software for easy operation and monitoring. Considerations Installation: Professional installation recommended to ensure optimal configuration. Maintenance: Regular inspections and battery replacements are crucial for reliability. Environment: Needs proper ventilation; avoid humid or extreme temperature environments. Cost: Initial investment can be significant; consider total cost of ownership including maintenance and energy savings. Applications Data Centers IT Infrastructure Telecommunications Industrial Equipment Medical Equipment Conclusion The Vertiv 40 kVA UPS is a versatile and powerful solution for ensuring continuous power availability and protecting critical infrastructure.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message

Still searching for