Gurugram
+918076792323

APC Smart-UPS X 1500VA Rack/Tower LCD 230V Descri...

update image
APC Smart-UPS X 1500VA Rack/Tower LCD 230V Description APC 1500VA Overview The Smart-UPS X 1500VA Rack/Tower LCD 230V from APC provides a continuous supply of battery power for connected items in the event of an AC power loss. It also safeguards devices from surges, spikes, lightning, and electrical disturbances. An Automatic Voltage Regulator (AVR) ensures clean and uninterrupted AC power by correcting low and high voltage conditions without using the battery. This UPS features a USB connection that enables configuration and control from a PC. It also features a SmartSlot for integrating it into a network for remote accessibility. Maintenance and servicing can be done from the front of the unit for easy installation and better space management. This UPS features an intelligent battery management that prolongs battery life by using a charging method based on the battery's age, capacity, temperature, and other factors. An automatic self-test function periodically checks the efficiency of the battery and provides notification when the battery is nearing the end of its usefulness. The system will also notify you if the battery is disconnected. An LED indicator lets you see at a glance power and battery status. The UPS also features an automatic restart function which will automatically power up devices after AC is restored. System Features Intuitive LCD Interface Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. Predictive Replace Battery Date Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. InfraStruXure Central Compatible Enables centralized management via APC InfraStruXure Central. Network Management Provides proactive power and environmental management via web and/or SNMP SmartSlot Customize UPS capabilities with management cards. Cold-Start Capable Provides temporary battery power when the utility power is out. Resettable Circuit Breakers Enables a quick recovery from overload events. Hot-Swappable Batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Disconnected Battery Notification Warns when a battery is not available to provide backup power. Automatic Self-Test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic Restart of Loads After UPS Shutdown Automatically starts up the connected equipment upon the return of utility power. Adjustable Voltage-Transfer Points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable Voltage Sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Audible Alarms Provides notification of changing utility power and UPS conditions. User-Replaceable Batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). USB Connectivity Provides management of the UPS via a USB port (not available on all models). Serial Connectivity Provides management of the UPS via a serial port. Temperature-Compensated Battery Charging Prolongs battery life by regulating the charge voltage according to battery temperature. Boost and Trim Automatic Voltage Regulation (AVR Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent Battery Management Maximizes battery performance, life, and reliability through intelligent, precision charging. Safety-Agency Approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Power Conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Predictive Failure Notification Provides early-warning fault analysis ensuring proactive component replacement. Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent Battery Management Maximizes battery performance, life, and reliability through intelligent, precision charging. Power Conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery. Intelligent Battery Management Maximizes battery performance, life, and reliability through intelligent, precision charging. Power Conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-Compensated Battery Charging Prolongs battery life by regulating the charge voltage according to battery temperature.
 2024-09-13T05:39:17

Keywords

The UPS USB port Mean Time serial port UPS Shutdown trained user backup power glance power LED indicator other factors AC power loss SNMP SmartSlot Audible Alarms quick recovery USB connection battery status UPS conditions charge voltage System Features connected loads early detection overload events navigation keys connected items charging method proactive power UPS capabilities USB Connectivity management cards space management easy installation continuous supply Network Management Cold-Start Capable multiple languages Power Conditioning battery temperature Serial Connectivity optimal performance battery performance battery replacement useful battery life APC 1500VA Overview accurate information remote accessibility input voltage window generator applications centralized management changing utility power uninterrupted AC power Hot-Swappable Batteries electrical disturbances temporary battery power high voltage conditions Intuitive LCD Interface environmental management other power disturbances output voltage regulation APC InfraStruXure Central User-Replaceable Batteries clean, uninterrupted power service provider equipment Periodic battery self-test automatic restart function specific power environments Resettable Circuit Breakers automatic self-test function Automatic Voltage Regulation early-warning fault analysis intelligent battery management Adjustable Voltage Sensitivity An Automatic Voltage Regulator long term maintenance planning proactive component replacement higher application availability Predictive Failure Notification intelligent, precision charging Predictive Replace Battery Date InfraStruXure Central Compatible Adjustable Voltage-Transfer Points Disconnected Battery Notification Warns Temperature-Compensated Battery Charging APC Smart-UPS X 1500VA Rack/Tower LCD 230V The Smart-UPS X 1500VA Rack/Tower LCD 230V

Related Posts

update image

Ups Battery AMC Solution

2025-09-24T12:45:04 , update date

 2025-09-24T12:45:04
update image

Ups Battery Supplier

2025-09-24T12:34:56 , update date

 2025-09-24T12:34:56
update image

Battery Retailer

2025-09-24T12:29:38 , update date

 2025-09-24T12:29:38
update image

Traction batteries dealer

2025-09-22T09:09:57 , update date

 2025-09-22T09:09:57