DELTA HPH Series, Three Phase, 20/30/40/60/80/100/120 kW
Best-in-class power protection with maximum power and cost efficiency
The Ultron HPH is a true online double-conversion UPS offering the best-in-class combination of maximum available power, unbeatable energy efficiency and superior power performance for small data centers and other mission critical applications. With fully rated power (kVA=kW), the Ultron HPH provides maximum available power without de-rating the UPS. Thanks to the three level IGBT topology for both PFC (power factor correction) and inverter, the Ultron HPH features up to 96% AC-AC efficiency. Delta’s advanced digital PFC control also contributes low iTHD < 3% and high input power factor > 0.99 resulting in significant TCO (Total Cost of Ownership) savings. Facilitating increased availability and power performance, the Ultron HPH is an ideal solution for protecting your mission critical operations.
Features & Benefits
Best-in-Class Power Performance and Efficiency
Fully rated power (kVA=kW) for maximum power availability
Leading AC-AC efficiency up to 96% saves energy costs
Low harmonic pollution (iTHD<3%) & high input power factor (>0.99) reduce upstream investment costs
Assured Reliability
Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
DSP based technology enables reduction in the number of electronic components to lower failure rate
Redundant auxiliary power and fan design* enhance system reliabil
* Applied for models HPH-60/80/100/120K
Watch-dog design of dual auxiliary power circuit to eliminate single-point failure to ensure reliability
Built-in manual bypass ensures continuous power to the load even if the UPS is under maintenance
Greater Flexibility
A wide choice of configurations, such as N+X redundancy, and hot stand-by
Adjustable charging current and battery voltage meet different battery configuration requirements
Flexible battery configuration optimizes battery investment
Superior Serviceability and Management
Swappable interior architecture and front access servicing enables quick and easy maintenance*
* Applied for models HPH-60/80/100/120K
Multi-connectivity interface supports remote UPS monitoring and management*
Specifications
Model
HPH-20K, HPH-30K, HPH-40K,
HPH-60K, HPH-80K, HPH-100K, HPH-120K
HPH-20K-BN/B, HPH-30K-BN/B, HPH-40K-BN/B
Power Rating
HPH-20K : 20 kVA/kW
HPH-30K : 30 kVA/kW
HPH-40K : 40 kVA/kW
HPH-60K : 60 kVA/kW
HPH-80K : 80 kVA/kW
HPH-100K : 100 kVA/kW
HPH-120K : 120 kVA/kW
Input
Nominal Voltage : 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
Voltage Range
HPH-20~40K : 300~477 Vac (full load), 228~300 Vac (70%~100% load)
HPH-60~120K : 332~477 Vac (full load), 228~332 Vac (63%~100% load)
Frequency : 40~70Hz
Power Factor : > 0.99 (full load)
Current Harmonic Distortion : < 3%
Output
Voltage : 380/220Vac, 400/230Vac, 415/240Vac (3 phase, 4-wire + G)
Voltage Regulation : ± 1 %
Voltage Harmonic Distortion
HPH-20~40K : < 1.5% (linear load)
HPH-60~120K : <2% (linear load)
Overload Capability
≤105 %: continuous
106% ~ ≤125%: 10 minutes
126% ~ ≤150%: 1 minute
>150%: 1 second
Output Power Factor : 1
Frequency : 50/60Hz +/- 0.05Hz
Battery
Battery Voltage : 240Vdc
Type : Support SMF/VRLA/Tubular/Ni-Cd
Quantity
HPH-20~40K : 32-50 pcs
HPH-60~120K : 32-46 pcs***
Charge Current (Max.) Built-in
HPH-20K : 5A
HPH-30/40K : 9A
HPH-60K : 10A
HPH-80K : 15A
HPH-100/120K : 20A
Typical Backup Time**
HPH-20K-BN/B : 15 min
HPH-30K-BN/B : 10 min
HPH-40K-BN/B : 9.5 min
Communication Interfaces
SMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1, REPO Port x 1, Charger Detection Port x 1, Input Dry Contact x 2, Output Dry Contact x 6, USB Port x 1*
Conformance
Safety : CE, RCM
UPS Classification According to IEC 62040-3 : VFI-SS-111
Other Features
Parallel Redundancy : Up to 4 units
Emergency Power Off : Yes (local and remote)
Maintenance Bypass Switch : Yes