Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEM5E67 65434678ae4e1df6fbef3981 Service https://locations.universalpower.co.in

VERTIV Liebert Make 10 KVA 3:1 Phase On-Line UP...

  • 2024-09-11T06:18:08

VERTIV Liebert Make 10 KVA 3:1 Phase On-Line UPS ( GXT MT+ Series ) GXT MT+ 10k31 True Online Double Conversion UPS with Liebert® GXT MT+ Series systems is true double conversion online UPS systems designed to provide with a capacity of 10-20kVA. Liebert® GXT MT+ units feature total isolation of the load from the mains - isolating input and output sections, and making the systems ideal for Data Networks / Small Data Centers/VOIP application. The units support hot standby configuration, making them suited for critical applications like banks. Features Liebert GXT-MT+ 10-20 kVA (3*1) Feature General Features IGBT Based Rectifier True Online Double Conversion with DSP Control Technology for High Performance and Reliability New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting Double Conversion Efficiency upto 90% Active Input Power Factor Correction 0.99 Wide Input Voltage window (110 - 280 Vac) for Indian Environmental Condition and for Optimized Battery Performance Also supports optional environmental monitoring detector for temperature, humidity and smoke. Password security protection and remote access management Configurable Output Voltage (200/208/220/230/240 Vac.) Generator Compatible with Wide Input Frequency Range (40 Hz-70 Hz) 4 Stage Extendable Charging Design for optimized Battery Performance Adjustable battery charging current 2/4/6/8/10/12/14/16 Amps according to battery capacity rating 50/60 Hz automatic frequency converter mode Intelligent monitoring with standard RS232/USB port plus slot available for RS485/Dry Contact/SNMP card Inbuilt OVCD Specification Output Specification Output Capacity (KVA ) 10 Kva Output Capacity (KW ) 9 Kw Output Power Factor 0.9 Power Factor Output Phase 1 Phase Output Voltage 208 Volt Other Output Voltage 220 Or 230 Volt Efficiency at Full Load >90 % Output Voltage Distortion <3 % Load Crest Factor 3:1 Output Waveform type Sine Wave UPS Parallel Upto 3 Nos. General Specifications Flexible Battery Option Yes Isolation Transformer Optional Paralleling Options Yes Rack Mounting Kit Not Available Paralleling Kit for Synchronising Optional Input Specification Input Voltage 400 Volt Other Input Voltage 380 Or 415 Volt Input Phase 3 Phase Input frequency 50/60Hz +/- 3 Hz Input Voltage Range (Output Derated) 265 - 478 Volt Input voltage range for main operations 305 - 478 Volt Input frequency Range 46 - 54 Hz Input Power Factor >0.99 None

VERTIV Liebert Make 10 KVA 3:1 Phase On-Line UPS ( GXT MT+ Series ) GXT MT+ 10k31 True Online Double Conversion UPS with Liebert® GXT MT+ Series systems is true double conversion online UPS systems designed to provide with a capacity of 10-20kVA. Liebert® GXT MT+ units feature total isolation of the load from the mains - isolating input and output sections, and making the systems ideal for Data Networks / Small Data Centers/VOIP application. The units support hot standby configuration, making them suited for critical applications like banks. Features Liebert GXT-MT+ 10-20 kVA (3*1) Feature General Features IGBT Based Rectifier True Online Double Conversion with DSP Control Technology for High Performance and Reliability New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting Double Conversion Efficiency upto 90% Active Input Power Factor Correction 0.99 Wide Input Voltage window (110 - 280 Vac) for Indian Environmental Condition and for Optimized Battery Performance Also supports optional environmental monitoring detector for temperature, humidity and smoke. Password security protection and remote access management Configurable Output Voltage (200/208/220/230/240 Vac.) Generator Compatible with Wide Input Frequency Range (40 Hz-70 Hz) 4 Stage Extendable Charging Design for optimized Battery Performance Adjustable battery charging current 2/4/6/8/10/12/14/16 Amps according to battery capacity rating 50/60 Hz automatic frequency converter mode Intelligent monitoring with standard RS232/USB port plus slot available for RS485/Dry Contact/SNMP card Inbuilt OVCD Specification Output Specification Output Capacity (KVA ) 10 Kva Output Capacity (KW ) 9 Kw Output Power Factor 0.9 Power Factor Output Phase 1 Phase Output Voltage 208 Volt Other Output Voltage 220 Or 230 Volt Efficiency at Full Load >90 % Output Voltage Distortion <3 % Load Crest Factor 3:1 Output Waveform type Sine Wave UPS Parallel Upto 3 Nos. General Specifications Flexible Battery Option Yes Isolation Transformer Optional Paralleling Options Yes Rack Mounting Kit Not Available Paralleling Kit for Synchronising Optional Input Specification Input Voltage 400 Volt Other Input Voltage 380 Or 415 Volt Input Phase 3 Phase Input frequency 50/60Hz +/- 3 Hz Input Voltage Range (Output Derated) 265 - 478 Volt Input voltage range for main operations 305 - 478 Volt Input frequency Range 46 - 54 Hz Input Power Factor >0.99 None

  • 2024-09-11T06:18:08

Keywords

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us