APC 6000VA UPS

The APC Smart-UPS RT 6000VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable power protection for critical equipment in various settings such as data centers, server rooms, and industrial environments. Here are some key features and specifications: Key Features: Power Capacity: 6000VA / 4800W – Suitable for medium-to-large systems that need substantial power backup. Rack-Mountable Design: The UPS can be mounted in a 19-inch rack, making it ideal for environments that require a space-efficient solution. Extended Runtime: It provides sufficient runtime to safely shut down connected equipment or continue operations during short power outages, depending on the load. Pure Sine Wave Output: Ensures high-quality power to sensitive equipment, avoiding power disturbances such as harmonic distortion or voltage spikes. Hot-Swappable Batteries: Allows for maintenance without powering down the UPS, increasing uptime and operational efficiency. LCD Display: A user-friendly LCD display provides detailed information about the UPS status, including input/output voltage, battery charge, and runtime. Extended Battery Options: Can be connected to external battery packs for increased runtime in case of prolonged power outages. Advanced Communication Features: Offers a variety of communication options such as USB, RS-232, or SNMP for monitoring and management. It’s compatible with APC’s PowerChute management software. Environmental Monitoring: Some models include environmental sensors to monitor conditions like temperature and humidity, ensuring the UPS operates in optimal conditions. Safety Features: It includes features such as overload protection, short-circuit protection, and battery optimization to ensure safe and efficient operation. Ideal Use Cases: Data Centers Server Rooms Network Equipment Industrial and Medical Equipment

Send Message
product image
UPS

APC offers a range of UPS (Uninterruptible Power Supply) systems, with the Smart-UPS series being particularly popular for providing reliable power protection. Here are some key specifications and details about the APC Smart-UPS models: General Specifications: Types: Line Interactive and On-Line models - Input Voltage: Typically 120V or 230V depending on the model Output Voltage: Pure sine wave output for compatibility with sensitive equipment Form Factor: Available in tower and rack-mount configurations Key Models: 1. APC Smart-UPS C Series: Ideal For: Small and medium businesses Features: Pure sine wave output LCD status display for real-time monitoring Multiple status indicators with load and battery bar graphs Configurable for tower or rack installation Models: SMC1000: 1000VA/670W SMC1500: 1500VA/1000W 2. APC Smart-UPS SMT Series: Features: Multi-function LCD screen DB-9, RS-232, Smart-Slot, and USB interface ports Extended runtime options with additional battery packs Models: SMT750: 750VA/500W SMT1000: 1000VA/670W SMT1500: 1500VA/1000W SMT2200: 2200VA/1980W 3. APC Smart-UPS SMX Series: Features: Similar to SMT series but with scalable runtime Extended run internal batteries Models: SMX750: 750VA/600W SMX1000: 1000VA/800W Key Features Across Models: Pure Sine Wave Output: Ensures compatibility with active PFC servers and sensitive electronics. LCD Display: Provides essential UPS status information at a glance. Multiple Output Receptacles: Varies by model, typically includes multiple 5-15R and 5-20R outlets. SmartConnect: Some models offer cloud monitoring capabilities for remote management. Applications: Data Centers: Protects critical servers and networking equipment. Telecommunications: Ensures reliable power for communication systems. Industrial Applications: Supports machinery and equipment during power interruptions. Advantages: Reliable Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Versatile Installation Options: Suitable for various environments and configurations. APC UPS systems are designed to provide robust power protection and management solutions for a wide range of applications, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Apc Ups Repairing And Maintenance In Aurangabad Sonipat

Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this: Common Issues with APC UPS Battery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge. Overload: The UPS may beep continuously if connected devices exceed its capacity. Faulty Output: No power output despite being plugged in. Firmware Issues: May require updates or resets. Tools Needed Multimeter Screwdriver set Replacement batteries (if needed) Laptop or PC for firmware updates Diagnostic software (if applicable) Testing Procedure Visual Inspection: Check for physical damage, burnt components, or loose connections. Inspect the battery for any signs of swelling or leakage. Battery Testing: Disconnect the UPS from the wall outlet. Use a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries). If the voltage is significantly lower, consider replacing the battery. Load Testing: Connect a load tester to the UPS and apply a known load (within the UPS capacity). Monitor the output voltage and see if it remains stable under load. Output Testing: Plug the UPS into the wall and turn it on. Measure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region). Check if the UPS switches to battery mode when you disconnect it from the wall. Overload Testing: Gradually increase the load on the UPS until it beeps or shuts down. Verify that it returns to normal operation once the overload is removed. Repair Procedures Battery Replacement: Follow the manufacturer’s guidelines for replacing batteries. Dispose of old batteries responsibly. Firmware Updates: Connect the UPS to a computer. Use APC’s software (like PowerChute) to check for and install firmware updates. Component Repair: If internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements. Reassembly: Carefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched. Final Testing After repairs, conduct a full load test to ensure the UPS operates correctly under stress. Monitor for any unusual noises or overheating during operation. Safety Precautions Always ensure the UPS is unplugged before performing internal inspections or repairs. Handle batteries with care, as they can be hazardous. Conclusion Regular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.

Send Message
product image
Apc Ups Repairing In Jawahar Colony Faridabad

Repairing an APC UPS (Uninterruptible Power Supply) involves troubleshooting and addressing common issues that can arise over time. Here’s a comprehensive guide to help you diagnose and repair your APC UPS: Safety Precautions Disconnect Power: Always unplug the UPS before performing any repairs or inspections. Use PPE: Wear safety goggles and gloves to protect against electric shock. Work in a Ventilated Area: Ensure good airflow to prevent overheating. Common Issues and Solutions 1. UPS Won't Turn On Check Power Source: Ensure the UPS is plugged in and the outlet is functional. Test the power cord for damage. Battery Issues: Inspect the battery for swelling, leaks, or corrosion. Use a multimeter to check battery voltage; if it's significantly low, it may need replacement. 2. Battery Replacement Identify Battery Type: Refer to the user manual for the specific battery model. Remove the Old Battery: Open the UPS case (usually requires a screwdriver). Disconnect the old battery, noting the connections. Install the New Battery: Connect the new battery securely. Close the UPS case and ensure all screws are tightened. 3. Overheating Check Ventilation: Ensure that the UPS is in a well-ventilated area. Clear any obstructions around vents. Inspect Fans: Check if the internal fans are operational. Clean any dust accumulation. 4. Frequent Alarms or Beeping Load Issues: Ensure that the connected load does not exceed the UPS capacity. Disconnect non-essential devices and see if the alarm stops. Battery Health: Run a self-test (if your model supports it) to check battery status. 5. Self-Test Failure Check Battery Voltage: Use a multimeter to check the voltage of the battery. Replace if below the recommended level. Internal Issues: If the self-test consistently fails, the internal circuitry might need inspection by a professional. Tools and Equipment Needed Multimeter (for voltage checks) Screwdriver set Replacement batteries (as needed) Cleaning cloth or compressed air (for dust removal) Safety equipment (gloves, goggles) General Repair Steps Visual Inspection: Check for any visible signs of damage, such as burnt components or damaged connectors. Inspect for loose wires and connections. Testing Components: Batteries: Measure the voltage and ensure it's within specifications. Fuses: Check fuses for continuity. Replace blown fuses as needed. Fans and Circuits: Ensure fans are operational and listen for unusual noises. Reassembly: After repairs, carefully reassemble the UPS. Ensure all screws and connections are secure before powering on. Testing the UPS: Once reassembled, plug in the UPS and perform a test by connecting a load. Monitor the UPS for any abnormal behavior. Conclusion Repairing an APC UPS can often be straightforward, particularly when it comes to replacing batteries or troubleshooting common issues. However, if the problem persists or if you are unsure about the repair process, it’s advisable to contact a professional technician or the manufacturer for support. Always refer to the specific user manual for detailed instructions related to your UPS model.

Send Message
product image
Emerson 5 KVA Online UPS

The Emerson 5 KVA Online UPS is designed to provide reliable power backup and protection for critical equipment. Here are some key details you might find helpful: Specifications Power Rating: 5 KVA (4500 watts) Input Voltage: Typically around 220-240 V AC Output Voltage: 220-240 V AC, often configurable Frequency: 50/60 Hz Topologies: Online Double-Conversion, providing isolation and voltage regulation. Output Waveform: Pure sine wave. Battery Type: Usually lead-acid or lithium-ion, depending on the model. Battery Runtime: Varies based on load; typically supports extended runtime with external battery packs. Charging Time: Full recharge time is usually 4-8 hours. Cooling Method: Typically air-cooled with internal fans. Dimensions: Varies by model but generally rack-mountable or tower form factors. Weight: Generally ranges from 30 to 50 kg, depending on the design. Features LCD Display: Shows real-time status, battery health, and load levels. Multiple Outlets: Usually equipped with a combination of IEC and NEMA outlets. Smart Battery Management: Extends battery life and optimizes performance. Surge Protection: Protects connected devices from power spikes. Remote Monitoring: Some models offer SNMP or USB connectivity for remote management. Maintenance Bypass: Allows maintenance without shutting down the connected equipment. Modularity: Options for expansion and additional battery packs. Applications IT Equipment Telecommunications Medical Devices Industrial Automation Data Centers Maintenance Regular maintenance is essential to ensure optimal performance, including: Checking battery health. Cleaning dust from vents and fans. Testing the UPS under load conditions.

Send Message
product image
UPS

Vertiv offers the 30kVA UPS models designed for high availability and critical power applications. Here’s a detailed overview of the key features and specifications: Key Model: 1. Vertiv Liebert EXS UPS: Power Rating: 30kVA / 30k - Input/Output Voltage: 400V in / 400V out, three-phase Technology: Online double conversion for superior power quality Power Factor: High power factor (0.9) for efficient energy usage Form Factor: Rack-mounted or tower configuration Features: Modular Design: Allows for easy scalability and maintenance without downtime Advanced Monitoring: Integrated monitoring capabilities with the Vertiv monitoring platform for real-time insights Battery Management: Intelligent battery management system to optimize battery life and performance User -Friendly Interface: Touchscreen display for easy navigation and monitoring of UPS status Energy Efficiency: Designed to meet or exceed ENERGY STAR certification for energy savings Applications: Data Centers: Provides reliable power to critical IT infrastructure Healthcare Facilities: Ensures uninterrupted power for life-saving medical equipment Telecommunications: Supports network operations and communications during power failures Industrial Applications: Protects sensitive equipment and processes from power disturbances Technical Specifications: Input Connection Types: IEC 320 EN 60320 C19, IEC 60320 C13 Output Connection Types: 6 x IEC 60320 C19, 2 x IEC 60320 C13 Operating Environment: Suitable for both indoor and outdoor installations, with temperature and humidity controls Advantages: High Availability: Designed for maximum uptime and reliability in critical applications Flexible Configuration: Can be customized to meet specific power requirements and installation environments Robust Protection: Offers comprehensive protection against power anomalies, ensuring equipment safety Vertiv\'s 30kVA UPS solutions are engineered to deliver reliable power protection and management, ensuring operational continuity and efficiency in demanding environments.

Send Message
product image
ups

Vertiv offers several models of 10kVA Uninterruptible Power Supplies (UPS) designed for critical power applications. Here’s a comprehensive overview of the key models and their features: Key Models: 1. Vertiv Liebert GXT5 UPS: Power Rating: 10kVA / 10kW Input/Output Voltage: 230V in / 230V out, single-phase Technology: Online double conversion for continuous power conditioning Power Factor: Unity power factor (1.0) for efficient load management Form Factor: Tower/rack mount Features: Remote Monitoring: Built-in Vertiv RDU101 communications card for remote monitoring and management Software Integration: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Scalable Runtime: Options for external battery cabinets to extend runtime during outages Display: Intuitive gravity sensing full-color LCD display for easy status monitoring Energy Efficiency: ENERGY STAR 2.0 certified for reduced energy consumption Applications: Data Centers: Protects critical IT infrastructure from power disturbances Healthcare: Ensures reliable power for medical equipment Telecommunications: Supports network reliability during outages Industrial: Safeguards machinery and sensitive equipment Technical Specifications: Input Connection Types: IEC 320 EN 60320 C13, IEC 60320 C19 Output Connection Types: 4 x IEC 60320 C19 Operating Environment: Designed for both centralized and edge computing applications Advantages: High Efficiency: Reduces operational costs with high power efficiency Robust Protection: Protects against all types of power disturbances, extending battery life Flexible Deployment: Suitable for various installation environments, including rack and tower configurations Vertiv\'s 10kVA UPS solutions are engineered to provide reliable power protection and management for critical applications, ensuring operational continuity during power interruptions.

Send Message
product image
Battery

The Amaron Quanta 12V 18Ah battery is a Sealed Maintenance-Free (SMF) Valve-Regulated Lead-Acid (VRLA) battery designed for long life and high performance. Technical Specifications **Brand **: Amaron Quanta Model Number: 12AL018 Rated Capacity: 18Ah Warranty: 12 months manufacturing warranty Battery Voltage: 12V Dimensions: 181x78x166 mm Weight (approx.): 6.5 kg Material: Container & Lid: ABS Battery Type: Lead-Acid battery with suspended electrolyte: Leak-proof Relative Humidity: Operating Relative Humidity: 0-95%, Storage Relative Humidity: 0-95% Operating Environment: 0 - 40 deg C Storage Temperature: -5 - 45 deg C Output Frequency: 47 - 63 Hz Items in Pack: 1 Piece Applications UPS Solar Power Packs Laboratory Equipment Spray machine etc. Useful For APC Backups Model Colour Grey Suitable For UPS System Telecommunication Equipment Fire Alarm & Security System Office Automation Equipment Universal Power System