Gurugram
+918076792323

'red cable'

Items tagged with 'red cable'

product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
Battery

Amaron batteries are well-known for their performance and reliability in various applications, including automotive, UPS systems, and renewable energy setups. Here’s a comprehensive overview of charging Amaron batteries, covering methods, parameters, and best practices. Charging Amaron Batteries 1. Charging Methods: Constant Current (CC) Charging: The charger supplies a constant current until the battery reaches a predefined voltage. Commonly used for lead-acid batteries, ensuring a safe and efficient charge. Constant Voltage (CV) Charging: After reaching the target voltage, the charger maintains that voltage while the current decreases. This method is suitable for maintaining battery charge without overcharging. Smart Chargers: These chargers automatically adjust voltage and current based on the battery's state. They often include features like temperature compensation and multi-stage charging. 2. Charging Parameters: Voltage: For lead-acid Amaron batteries, the charging voltage typically ranges from 2.25V to 2.40V per cell. For a 12V battery (6 cells), this translates to about 13.5V to 14.4V. Current: The charging current should be set to 10-30% of the battery's capacity (C-rate). For example, a 100Ah battery should be charged at 10A to 30A. Temperature Compensation: Adjust the charging voltage based on the ambient temperature to avoid damage. Generally, for every degree Celsius above 25°C, reduce the charging voltage by 0.005V per cell. 3. Charging Stages: Bulk Charge: The initial phase where maximum current is applied to quickly charge the battery. This stage continues until the battery reaches approximately 70-80% of its capacity. Absorption Charge: The charger maintains a constant voltage, allowing the current to taper off as the battery approaches full charge. This phase ensures the battery reaches full capacity without overcharging. Float Charge: A lower voltage is maintained to keep the battery fully charged without overcharging. This is essential for maintaining the battery in a ready state for immediate use. Best Practices for Charging Amaron Batteries: Use the Right Charger: Always use a charger specifically designed for the type of battery you are charging (lead-acid, AGM, etc.). Avoid Deep Discharge: Regularly charge the battery to prevent deep discharges, which can shorten battery life. Monitor Temperature: Ensure the charging environment is within the recommended temperature range (typically 15°C to 25°C). Regular Maintenance: Periodically check the battery's state of charge and electrolyte levels (if applicable). Clean terminals and connections to ensure efficient charging. Follow Manufacturer Guidelines: Always refer to the specific charging instructions provided by Amaron for the particular battery model. Conclusion Proper charging of Amaron batteries is vital for maximizing their lifespan and performance. By following the recommended charging methods, parameters, and best practices, users can ensure that their batteries operate efficiently and reliably. If you have specific models in mind or need further details, feel free to ask!

Send Message
product image
Apc Ups Repairing And Maintenance In Aurangabad Sonipat

Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this: Common Issues with APC UPS Battery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge. Overload: The UPS may beep continuously if connected devices exceed its capacity. Faulty Output: No power output despite being plugged in. Firmware Issues: May require updates or resets. Tools Needed Multimeter Screwdriver set Replacement batteries (if needed) Laptop or PC for firmware updates Diagnostic software (if applicable) Testing Procedure Visual Inspection: Check for physical damage, burnt components, or loose connections. Inspect the battery for any signs of swelling or leakage. Battery Testing: Disconnect the UPS from the wall outlet. Use a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries). If the voltage is significantly lower, consider replacing the battery. Load Testing: Connect a load tester to the UPS and apply a known load (within the UPS capacity). Monitor the output voltage and see if it remains stable under load. Output Testing: Plug the UPS into the wall and turn it on. Measure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region). Check if the UPS switches to battery mode when you disconnect it from the wall. Overload Testing: Gradually increase the load on the UPS until it beeps or shuts down. Verify that it returns to normal operation once the overload is removed. Repair Procedures Battery Replacement: Follow the manufacturer’s guidelines for replacing batteries. Dispose of old batteries responsibly. Firmware Updates: Connect the UPS to a computer. Use APC’s software (like PowerChute) to check for and install firmware updates. Component Repair: If internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements. Reassembly: Carefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched. Final Testing After repairs, conduct a full load test to ensure the UPS operates correctly under stress. Monitor for any unusual noises or overheating during operation. Safety Precautions Always ensure the UPS is unplugged before performing internal inspections or repairs. Handle batteries with care, as they can be hazardous. Conclusion Regular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.

Send Message
product image
Amaron Batteries Repairing And Charging In sohna sector 36 Gurgaon

Repairing and charging Amaron batteries (or any lead-acid battery) requires caution and adherence to safety procedures. Here’s a comprehensive guide on how to repair and charge Amaron batteries: Safety Precautions Personal Protective Equipment (PPE): Always wear safety goggles and gloves. Ventilation: Work in a well-ventilated area to avoid inhaling harmful gases. Avoid Short Circuits: Be careful with tools and connections to prevent sparks or short circuits. Tools and Equipment Needed Multimeter (for checking voltage and condition) Battery charger compatible with lead-acid batteries Battery terminal cleaner or wire brush Distilled water (if applicable, for batteries that can be serviced) Insulation tape Safety equipment (gloves, goggles) Steps to Repair and Charge Amaron Batteries 1. Inspect the Battery Check for physical damage, such as cracks or leaks. Inspect terminals for corrosion. Clean terminals with a wire brush if necessary. 2. Test the Battery Use a multimeter to check the voltage. A fully charged 12V battery should read around 12.6 to 12.8 volts. If the voltage is significantly lower (e.g., below 12 volts), the battery may need charging or could be damaged. 3. Charging the Battery Select the Right Charger: Use a smart charger or a lead-acid battery charger that matches the battery’s specifications. Connect the Charger: Connect the positive (+) terminal of the charger to the positive terminal of the battery. Connect the negative (-) terminal of the charger to the negative terminal of the battery. Set the Charger: Choose the appropriate charging mode (usually a slow charge is best for lead-acid batteries). Monitor Charging: Charging time will vary; typically, it can take several hours to overnight. Monitor the charging process. 4. Check Battery Condition After Charging Once fully charged, use the multimeter to measure the voltage again. Perform a load test (if available) to ensure the battery can hold a charge under load. 5. Repairing Cells (if applicable) For Serviceable Batteries: If the battery has removable caps: Check the electrolyte level; add distilled water if needed. Ensure the specific gravity of the electrolyte is within the acceptable range (use a hydrometer). Re-seal the Caps: Make sure all caps are securely in place after checking. 6. Final Inspection and Reinstallation Ensure all connections are clean and secure. Reinstall the battery in the vehicle, connecting the positive terminal first, followed by the negative terminal. Use insulation tape to secure any exposed connections. Additional Tips Avoid Overcharging: Overcharging can damage the battery and reduce its lifespan. Always use a charger with an automatic shut-off feature. Regular Maintenance: Periodically check battery health, clean terminals, and keep the battery charged to prolong its life. Replacement: If the battery fails to hold a charge after multiple attempts, consider replacing it. Conclusion Repairing and charging Amaron batteries can extend their life if done correctly. Always prioritize safety and follow proper procedures to ensure efficient operation. If you're uncertain about any step, consult a professional or refer to the manufacturer's guidelines.

Send Message
product image
Amaron Quanta 12V 160Ah SMF Battery In Ajronda Chowk Faridabad

The Amaron Quanta 12V 160Ah SMF battery is a sealed maintenance-free (SMF) lead acid battery designed for various applications such as UPS systems, telecommunication equipment, fire alarm and security systems, office automation equipment, and EPAB X & electronic equipment. Product Specifications Brand: Amaron Quanta Rated Capacity: 160 Ah Warranty: 24 Months Battery Voltage: 12 V Dimensions: Not specified Weight: Not specified Material: Container & Lid: PPCP Containers with low permeability ensuring no water loss Battery Type: Lead-Acid battery with suspended electrolyte: Leak-proof Relative Humidity: Operating Relative Humidity: 0-95%, Storage Relative Humidity: 0-95% Colour: Not specified Model: Not specified Operating Environment: 0 - 40 deg C Storage Temperature: -5 - 45 deg C Output Frequency: 47 - 63 Hz Items in Pack: 1 Piece Features PPCP Containers with low permeability ensuring no water loss Proven AGM technology for maintenance-free usage Reinforced end walls ensure impact resistance Thicker grids & higher separator compression extend lifespan Inter cell weld between cells provide a high reliable, low resistance current path Unique heavy duty corrosion-resistant alloy for positive grids Overall increase in cyclic life in tropical environments Radgrid profile provides lower internal resistance Superior high discharge performance Instacharge - a patented paste recipe for excellent charge acceptance Low self-discharge rates for extended storage periods Conforms to International standards – JIS8702C Clean and Sleek looks Applications UPS System Telecommunication Equipment Fire Alarm & Security System Office Automation Equipment EPABX & Electronic Laboratory Equipment Spray machine Medical Equipment Railway Signaling Systems Other general-purpose applications Warranty 24 Months manufacturing warranty applicable 2 Year Carry In warranty from the date of sale Additional Information The battery is designed to provide efficient backup for an uninterrupted power supply and reliable standby service life. It is a preferred 12V VRLA SMF battery brand by most reputed UPS manufacturers and customers across various segments. The battery is manufactured at world-class facilities in association with Johnson Controls. The Amaron Quanta 12V 160Ah SMF battery is a reliable and efficient power backup solution for various applications.

Send Message
product image
Battery

The Amaron Quanta 12V 28Ah SMF battery is a sealed maintenance-free (SMF) lead acid battery designed for various applications such as UPS systems, telecommunication equipment, fire alarm and security systems, office automation equipment, and EPAB X & electronic equipment. Product Specifications Brand: Amaron Quanta Rated Capacity: 28 Ah Warranty: 18 Months Battery Voltage: 12 V Dimensions: 165x125x110 mm Weight: 8.5 kg Material: Container & Lid: ABS Battery Type: Lead-Acid battery with suspended electrolyte: Leak-proof Relative Humidity: Operating Relative Humidity: 0-95%, Storage Relative Humidity: 0-95% Colour: Grey Model: 12AVL028 Operating Environment: 0 - 40 deg C Storage Temperature: -5 - 45 deg C Output Frequency: 47 - 63 Hz Items in Pack: 1 Piece Features Reliable Functionality Suitable for Fast Recharging Sealed Maintenance Free Patented Heavy Duty Alloy Construction Advanced AGM Valve Regulated technology ECO Friendly Low self-discharge rates for extended storage periods Applications UPS System Telecommunication Equipment Fire Alarm & Security System Office Automation Equipment EPABX & Electronic Laboratory Equipment Spray machine Medical Equipment Railway Signaling Systems Other general-purpose applications Warranty 18 Months manufacturing warranty applicable 1 Year Carry In warranty from the date of sale Additional Information The battery is designed to provide efficient backup for an uninterrupted power supply and reliable standby service life. It is a preferred 12V VRLA SMF battery brand by most reputed UPS manufacturers and customers across various segments. The battery is manufactured at world-class facilities in association with Johnson Controls. The Amaron Quanta 12V 28Ah SMF battery is a reliable and efficient power backup solution for various applications.

Send Message
product image
Battery

The Amaron Quanta 12V 12AH battery is a sealed maintenance-free (SMF) lead acid battery designed for various applications such as UPS systems, telecommunication equipment, fire alarm and security systems, office automation equipment, and EPAB X & electronic equipment. Product Specifications Brand: Amaron Quanta Rated Capacity: 12 Ah Warranty: 12 Months Battery Voltage: 12 V Dimensions: 100x151x98 mm Weight: 4 kg Material: Container & Lid: ABS Battery Type: Lead-Acid battery with suspended electrolyte: Leak-proof Relative Humidity: Operating Relative Humidity: 0-95%, Storage Relative Humidity: 0-95% Colour: Grey Model: 12AVL012 Operating Environment: 0 - 40 deg C Storage Temperature: -5 - 45 deg C Output Frequency: 47 - 63 Hz Items in Pack: 1 Piece Features Reliable Functionality Suitable for Fast Recharging Sealed Maintenance Free Patented Heavy Duty Alloy Construction Advanced AGM Valve Regulated technology ECO Friendly Applications UPS System Telecommunication Equipment Fire Alarm & Security System Office Automation Equipment EPABX & Electronic Laboratory Equipment Spray machine etc. Warranty 12 Months manufacturing warranty applicable 1 Year Carry In warranty from the date of sale Additional Information The battery is designed to provide efficient backup for an uninterrupted power supply and reliable standby service life. It is a preferred 12V VRLA SMF battery brand by most reputed UPS manufacturers and customers across various segments.

Send Message
product image
Amaron Tubular Battery In Faridabad

Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points: Design: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions. Applications: Commonly used in inverters, solar power systems, and other backup power solutions. Durability: Known for high resistance to corrosion and low maintenance requirements. Performance: Excellent charge retention and high power output, even in harsh conditions. Maintenance: Requires periodic checking of water levels and occasional equalization charging. Amaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.

Send Message

Still searching for
red cable?