Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +918048033031 (International callers) or 08048033031 (Indian callers).
The Vertiv 10kVA UPS is a high-performance uninterruptible power supply system designed to provide continuous power conditioning and protection for mission-critical systems. It's available in various models, including the Liebert GXT5, Liebert EX L, and Liebert NX.
Technical Specifications
Load Capacity (VA): 10000 VA
Output Voltage: 120 V AC, 208 V AC
Waveform Type: Pure Sine Wave
User Selectable Output: 208/120VAC
Utility (AC) Mode Overload:
105% to 125% for 5 minutes
125% to 150% for 60 seconds
150% (impact load) minimum 200 ms
Management Features
Bypass Switch: Automatic & Manual, Internal
Remote Monitoring: Built-in Vertiv RDU101 communications card
Software: Free Vertiv Power Insight software for monitoring and management
Physical Characteristics
Form Factor: Tower/Rack Mount
Dimensions: Not specified
Weight: Not specified
Certifications and Compliance
ENERGY STAR 2.0 Certified: Yes
Other Certifications: Not specified
Additional Features
Scalable Runtime Options: Matching external battery cabinets for extended runtime
LCD Display: Intuitive gravity sensing full-color LCD display
Amaron batteries are well-known for their performance and reliability in various applications, including automotive, UPS systems, and renewable energy setups. Here’s a comprehensive overview of charging Amaron batteries, covering methods, parameters, and best practices.
Charging Amaron Batteries
1. Charging Methods:
Constant Current (CC) Charging:
The charger supplies a constant current until the battery reaches a predefined voltage.
Commonly used for lead-acid batteries, ensuring a safe and efficient charge.
Constant Voltage (CV) Charging:
After reaching the target voltage, the charger maintains that voltage while the current decreases.
This method is suitable for maintaining battery charge without overcharging.
Smart Chargers:
These chargers automatically adjust voltage and current based on the battery's state.
They often include features like temperature compensation and multi-stage charging.
2. Charging Parameters:
Voltage:
For lead-acid Amaron batteries, the charging voltage typically ranges from 2.25V to 2.40V per cell.
For a 12V battery (6 cells), this translates to about 13.5V to 14.4V.
Current:
The charging current should be set to 10-30% of the battery's capacity (C-rate).
For example, a 100Ah battery should be charged at 10A to 30A.
Temperature Compensation:
Adjust the charging voltage based on the ambient temperature to avoid damage.
Generally, for every degree Celsius above 25°C, reduce the charging voltage by 0.005V per cell.
3. Charging Stages:
Bulk Charge:
The initial phase where maximum current is applied to quickly charge the battery.
This stage continues until the battery reaches approximately 70-80% of its capacity.
Absorption Charge:
The charger maintains a constant voltage, allowing the current to taper off as the battery approaches full charge.
This phase ensures the battery reaches full capacity without overcharging.
Float Charge:
A lower voltage is maintained to keep the battery fully charged without overcharging.
This is essential for maintaining the battery in a ready state for immediate use.
Best Practices for Charging Amaron Batteries:
Use the Right Charger:
Always use a charger specifically designed for the type of battery you are charging (lead-acid, AGM, etc.).
Avoid Deep Discharge:
Regularly charge the battery to prevent deep discharges, which can shorten battery life.
Monitor Temperature:
Ensure the charging environment is within the recommended temperature range (typically 15°C to 25°C).
Regular Maintenance:
Periodically check the battery's state of charge and electrolyte levels (if applicable).
Clean terminals and connections to ensure efficient charging.
Follow Manufacturer Guidelines:
Always refer to the specific charging instructions provided by Amaron for the particular battery model.
Conclusion
Proper charging of Amaron batteries is vital for maximizing their lifespan and performance. By following the recommended charging methods, parameters, and best practices, users can ensure that their batteries operate efficiently and reliably. If you have specific models in mind or need further details, feel free to ask!
The Vertiv 3kVA online UPS is a reliable power solution designed for critical applications. Here are its key features and specifications:
Key Features:
True double conversion online UPS technology for high-quality power output
Compact tower design for reduced footprint and increased reliability
Eco mode for high efficiency and reduced total cost of ownership (TCO)
Intelligent monitoring and network management capabilities for enhanced system shutdown and control
Scalable runtime options with matching external battery cabinets for extended backup time
Specifications:
Capacity: 3kVA
Type: Double Conversion Online UPS
Volts: 230V AC (single-phase)
Power Factor: 0.9
Efficiency: Up to 95%
Input Voltage Range: 180-280V AC (single-phase)
Output Voltage: 230V AC (single-phase)
Frequency: 50/60 Hz
Battery Type: Valve Regulated Lead Acid (VRLA)
Battery Capacity: Up to 12Ah
Battery Life: Up to 5 years
Dimensions: 440 x 220 x 640 mm (H x W x D)
Weight: Approximately 30 kg
Applications:
Small to medium-sized data centers
Network operation centers
Server rooms
Telecommunication systems
Medical equipment
Industrial control systems
Security systems
Building management systems
Benefits:
High-quality power output
Compact design
High efficiency
Scalable runtime options
Intelligent monitoring and network management capabilities
Warranty and Support:
Warranty period: Up to 3 years
Customer support: Available from the manufacturer and authorized dealers
The Vertiv 60 kVA UPS is a high-capacity power solution designed for critical power applications. Here are its key features and specifications:
Key Features:
Highly efficient transformer-free double conversion technology for installation and running cost savings
Scalable and flexible design for easy upgrades and expansion
High power density for reduced footprint and increased reliability
Advanced battery management system for extended battery life
Wide input voltage range for improved compatibility with various power sources
High-quality components and robust design for increased reliability and reduced maintenance
Advanced monitoring and control capabilities for remote monitoring and management
Specifications:
Capacity: 60 kVA
Type: Double Conversion Online UPS
Volts: 400V AC (3-phase)
Power Factor: 0.9
Efficiency: Up to 96.5%
Input Voltage Range: 340-460V AC (3-phase)
Output Voltage: 400V AC (3-phase)
Frequency: 50/60 Hz
Battery Type: Valve Regulated Lead Acid (VRLA)
Battery Capacity: Up to 240Ah
Battery Life: Up to 10 years
Dimensions: 1200 x 600 x 1800 mm (H x W x D)
Weight: Approximately 1200 kg
Applications:
Data Centers
Online UPS Inverter Systems
Banks & Financial Markets
Network Operation Centers
Semiconductor Manufacturing
Power Generation Plants
Hospital & Testing Laboratories
Portable Testing & Measuring Instruments
Vending machines & Weighing Scales
Office Automation Equipment
Fire Alarm & Security Systems
Electronic PABX Systems
Telecommunication Systems
Process Instrumentation & Control
Railway Signalling
Power Plants & Substations
Benefits:
High efficiency and reliability
Scalable and flexible design
Advanced battery management system
Wide input voltage range
High-quality components and robust design
Advanced monitoring and control capabilities
Warranty and Support:
Warranty period: Up to 5 years
Customer support: Available from the manufacturer and authorized dealers
The Amaron Quanta 12V 150Ah battery is a Sealed Maintenance Free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for UPS applications. It has a capacity of 150Ah and operates at 12 volts. The battery comes with a warranty of 24 months.
Key Features:
PPCP Containers with low permeability ensures that there is no water loss
Lead Acid Storage Type @ C20 Rating
Proven AGM technology ensures maintenance-free characteristics
Reinforced end walls improve impact resistance
Thicker grids and higher separator compression prolong life expectancy
Inter cell weld between cells provide a high reliable, low resistance current path
A unique heavy duty corrosion-resistant alloy for positive grids, to increase cyclic life in tropical environments
Radgrid profile provides lower internal resistance and superior high discharge performance
Instacharge a patented paste recipe for excellent charge acceptance
Low self-discharge rates for extended storage periods
Conforms to International standards – JIS8702C
Design float life of 10 years
Clean and Sleek looks
Specifications:
Capacity: 150Ah
Type: SMF, VRLA (Sealed Maintenance Free, Valve Regulated Lead Acid)
Volts: 12V
Warranty: 24 months
Weight: 46 kgs (approx.)
Dimensions: 406168283 in mm (approx.)
Applications:
Data Centers
Online UPS Inverter Systems
Banks & Financial Markets
Network Operation Centers
Semiconductor Manufacturing
Power Generation Plants
Hospital & Testing Laboratories
Portable Testing & Measuring Instruments
Vending machines & Weighing Scales
Office Automation Equipment
Fire Alarm & Security Systems
Electronic PABX Systems
Telecommunication Systems
Process Instrumentation & Control
Railway Signalling
Power Plants & Substations
Benefits:
High performance and reliability
Low maintenance cost
Long lifespan
Environmentally friendly
Warranty and Support:
Warranty period: 24 months
Customer support: Available from the manufacturer and authorized dealers
The Amaron Quanta 12V 160Ah battery is a Sealed Maintenance Free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for UPS applications. It has a capacity of 160Ah and operates at 12 volts. The battery comes with a warranty of 24 months.
Key Features:
PPCP Containers with low permeability ensures that there is no water loss
Lead Acid Storage Type @ C20 Rating
Proven AGM technology ensures maintenance-free characteristics
Reinforced end walls improve impact resistance
Thicker grids and higher separator compression prolong life expectancy
Inter cell weld between cells provide a high reliable, low resistance current path
A unique heavy duty corrosion-resistant alloy for positive grids, to increase cyclic life in tropical environments
Radgrid profile provides lower internal resistance and superior high discharge performance
Instacharge a patented paste recipe for excellent charge acceptance
Low self-discharge rates for extended storage periods
Conforms to International standards – JIS8702C
Design float life of 10 years
Clean and Sleek looks
Specifications:
Capacity: 160Ah
Type: SMF, VRLA (Sealed Maintenance Free, Valve Regulated Lead Acid)
Volts: 12V
Warranty: 24 months
Weight: 52 kgs (approx.)
Dimensions: 445168283 in mm (approx.)
Applications:
Data Centers
Online UPS Inverter Systems
Banks & Financial Markets
Network Operation Centers
Semiconductor Manufacturing
Power Generation Plants
Hospital & Testing Laboratories
Portable Testing & Measuring Instruments
Vending machines & Weighing Scales
Office Automation Equipment
Fire Alarm & Security Systems
Electronic PABX Systems
Telecommunication Systems
Process Instrumentation & Control
Railway Signalling
Power Plants & Substations
Benefits:
High performance and reliability
Low maintenance cost
Long lifespan
Environmentally friendly
Warranty and Support:
Warranty period: 24 months
Customer support: Available from the manufacturer and authorized dealers
The Amaron Quanta 12V 180Ah battery is a tubular battery designed for inverter applications. It has a capacity of 180Ah and operates at 12 volts. The battery comes with a warranty of 2-4 years .
Key Features:
High cranking power
Zero maintenance
High heat tolerance capacity
Factory charged
Vibration resistant
Compatible with any brand of inverter
Specifications:
Capacity: 180Ah
Type: Tubular Battery
Volts: 12V
Warranty: 2-4 years
Weight: Not specified
Dimensions: Not specified
Applications:
Inverter applications
UPS systems
Renewable energy systems
Telecommunication systems
Benefits:
High performance and reliability
Low maintenance cost
Long lifespan
Environmentally friendly
Warranty and Support:
Warranty period: 2-4 years
Customer support: Available from the manufacturer and authorized dealers
The Amaron Hiway 90Ah battery is a high-performance automotive battery designed for passenger cars. Here's an overview of the Amaron Hiway 90Ah battery and its specifications:
Key Features:
90Ah capacity with a 12V rating
Maintenance-free calcium-alloy technology for low maintenance and long life
High cold cranking amps (CCA) for reliable starting in extreme temperatures
Advanced grid design for improved performance and durability
Robust construction with a reinforced polypropylene casing
Designed for Indian road conditions with a high vibration resistance
Technical Specifications:
Capacity:
90Ah
Voltage:
12V
Cold Cranking Amps (CCA):
720 CCA
Reserve Capacity (RC):
180 minutes
Dimensions:
Length: 353 mm
Width: 175 mm
Height: 190 mm
Weight:
23.5 kg
Product Overview:
The Amaron Hiway 90Ah battery is designed to provide reliable starting power and long battery life. With its advanced grid design and calcium-alloy technology, it offers improved performance and durability. The battery is designed to withstand Indian road conditions with high vibration resistance, making it an ideal choice for passenger cars.
Warranty:
The Amaron Hiway 90Ah battery comes with a 48-month warranty.
Vertiv offers a wide range of Uninterruptible Power Supply (UPS) systems with various capacities, configurations, and features to cater to different applications and requirements. Here's an overview of the different types of UPS systems and their specifications:
Types of UPS Systems:
Vertiv Liebert PSA5 UPS: Economical, line-interactive UPS battery backup technology designed for small to medium-sized applications.
Capacity: 1-5 kVA
Features: Automatic Voltage Regulation (AVR), compact design, and hot-swappable batteries
Vertiv Liebert PS15 UPS: Compact, Automatic Voltage Regulation (AVR) line-interactive UPS system designed for small to medium-sized applications.
Capacity: 1,000-5,000VA
Features: Compact design, 1U and 2U rack/tower configuration, and hot-swappable batteries
Vertiv Liebert ITA2 UPS: High-performance, double-conversion UPS system designed for small to medium-sized data centers and edge computing applications.
Capacity: 1-3 kVA
Features: High efficiency, compact design, and advanced monitoring and control capabilities
Vertiv Liebert NX UPS: High-performance, double-conversion UPS system designed for medium-sized to large data centers and critical applications.
Capacity: 5-20 kVA
Features: High efficiency, modular design, and advanced monitoring and control capabilities
Vertiv Liebert EXL UPS: High-performance, double-conversion UPS system designed for large data centers and critical applications.
Capacity: 20-120 kVA
Features: High efficiency, modular design, and advanced monitoring and control capabilities
Vertiv Liebert GXT UPS: High-performance, double-conversion UPS system designed for large data centers and critical applications.
Capacity: 10-50 kVA
Features: High efficiency, modular design, and advanced monitoring and control capabilities
Common Features:
High efficiency: Up to 95% efficiency in double conversion mode
High power density: Compact design with high power density
Flexibility: Modular design for easy scalability and flexibility
Reliability: Built-in redundancy and hot-swappable components for high reliability
Monitoring: Advanced monitoring and control capabilities
Technical Specifications:
Input voltage: 230V AC
Output voltage: 230V AC
Frequency: 50/60 Hz
Efficiency: Up to 95% in double conversion mode
Power factor: 0.9
Battery type: Valve-regulated lead-acid (VRLA) batteries
Battery life: Up to 5 years
Warranty and Support:
Standard warranty: 2 years
Extended warranty options available
24/7 technical support and service available
Vertiv offers a range of Uninterruptible Power Supply (UPS) systems with capacities of 1 kVA, 2 kVA, and 3 kVA. These UPS systems are designed to provide reliable power protection and high performance for critical applications .
Key Features:
High efficiency: Up to 95% efficiency in double conversion mode
High power density: Compact design with high power density
Flexibility: Modular design for easy scalability and flexibility
Reliability: Built-in redundancy and hot-swappable components for high reliability
Monitoring: Advanced monitoring and control capabilities
Vertiv Liebert ITA2 UPS:
The Vertiv Liebert ITA2 UPS is a 1-3 kVA UPS system designed for small to medium-sized data centers and edge computing applications.
It features a compact design, high efficiency, and advanced monitoring and control capabilities.
The Liebert ITA2 UPS is available in 1 kVA, 2 kVA, and 3 kVA models.
Benefits:
Reliable power protection for critical applications
High efficiency and low total cost of ownership
Flexible and scalable design for easy upgrades and expansion
Advanced monitoring and control capabilities for easy management
Technical Specifications:
Input voltage: 230V AC
Output voltage: 230V AC
Frequency: 50/60 Hz
Efficiency: Up to 95% in double conversion mode
Power factor: 0.9
Battery type: Valve-regulated lead-acid (VRLA) batteries
Battery life: Up to 5 years
Warranty and Support:
Standard warranty: 2 years
Extended warranty options available
24/7 technical support and service available
Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this:
Common Issues with APC UPS
Battery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge.
Overload: The UPS may beep continuously if connected devices exceed its capacity.
Faulty Output: No power output despite being plugged in.
Firmware Issues: May require updates or resets.
Tools Needed
Multimeter
Screwdriver set
Replacement batteries (if needed)
Laptop or PC for firmware updates
Diagnostic software (if applicable)
Testing Procedure
Visual Inspection:
Check for physical damage, burnt components, or loose connections.
Inspect the battery for any signs of swelling or leakage.
Battery Testing:
Disconnect the UPS from the wall outlet.
Use a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries).
If the voltage is significantly lower, consider replacing the battery.
Load Testing:
Connect a load tester to the UPS and apply a known load (within the UPS capacity).
Monitor the output voltage and see if it remains stable under load.
Output Testing:
Plug the UPS into the wall and turn it on.
Measure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region).
Check if the UPS switches to battery mode when you disconnect it from the wall.
Overload Testing:
Gradually increase the load on the UPS until it beeps or shuts down.
Verify that it returns to normal operation once the overload is removed.
Repair Procedures
Battery Replacement:
Follow the manufacturer’s guidelines for replacing batteries.
Dispose of old batteries responsibly.
Firmware Updates:
Connect the UPS to a computer.
Use APC’s software (like PowerChute) to check for and install firmware updates.
Component Repair:
If internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements.
Reassembly:
Carefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched.
Final Testing
After repairs, conduct a full load test to ensure the UPS operates correctly under stress.
Monitor for any unusual noises or overheating during operation.
Safety Precautions
Always ensure the UPS is unplugged before performing internal inspections or repairs.
Handle batteries with care, as they can be hazardous.
Conclusion
Regular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.
Apc Ups Repairing And Maintenance In Aurangabad Sonipat
Using Amaron batteries with Vertiv UPS (Uninterruptible Power Supply) systems can provide a reliable backup power solution for various applications. Here’s a comprehensive overview:
Vertiv UPS Overview
Purpose: Designed to ensure continuous power supply during outages, protect against power surges, and stabilize voltage fluctuations.
Types: Includes models for home use, data centers, industrial applications, and more.
Key Features:
High Efficiency: Advanced technologies for reduced energy consumption.
Modular Design: Some models allow for scalable capacity as needed.
User-Friendly Interface: LCD displays show battery status, load information, and alerts.
Amaron Batteries Overview
Type: Generally lead-acid batteries (deep-cycle) or, in some cases, lithium-ion.
Voltage Options: Commonly available in 12V, suitable for most Vertiv UPS systems.
Capacity: Ranges from 46Ah to over 200Ah, depending on your backup needs.
Compatibility
Voltage Matching: Ensure the Amaron battery voltage (e.g., 12V) matches the UPS requirements.
Capacity Selection: Choose a battery capacity that meets the total load and desired backup duration. Calculate based on the wattage of connected devices.
Installation
Connecting the Battery:
Connect the positive (+) terminal of the Amaron battery to the UPS positive terminal.
Connect the negative (-) terminal to the UPS negative terminal.
Ensure Secure Connections: Make sure all connections are tight to avoid arcing or power loss.
Performance Benefits
Extended Runtime: Higher capacity Amaron batteries can provide longer backup durations during outages.
Deep Cycle Capability: Designed to handle regular deep discharges, making them ideal for UPS applications.
Low Maintenance: Many Amaron batteries require minimal maintenance, offering convenience for users.
Maintenance
Regular Inspections: Periodically check for corrosion on terminals and ensure all connections are secure.
Battery Monitoring: Use a multimeter or UPS diagnostics to check battery health and voltage levels.
Signs of Replacement: Be aware of performance degradation, such as reduced backup time or inability to hold charge.
Safety Precautions
Adequate Ventilation: Ensure good airflow around the UPS and battery to prevent gas accumulation, especially with lead-acid batteries.
Proper Charging Practices: Follow guidelines to prevent overcharging, which can damage the battery.
Conclusion
Pairing Amaron batteries with Vertiv UPS systems can create a robust and reliable backup power solution. This combination helps ensure your devices remain operational during power outages and protects against voltage irregularities. Always consult the user manuals for both the UPS and batteries to ensure proper installation and compatibility, maximizing the performance of your power backup system.